Page 171
NEAX2000 IVS2 CCIS System ManualPage 158 ND-70918 (E), Issue 1.0 CHAPTER 3 SYSTEM DATA PROGRAMMING Centralized Billing-CCIS SMDR with AP00 Programming (1) PROGRAMMING FOR CENTER OFFICE When sending billing information from local offices to SMDR of Center Office, do the following programming. When sending billing information from both Center Office and Local Office to SMDR of Center Office, do the following programming in addition to the basic programming of SMDR with AP00. For details of the SMDR with...
Page 172
CHAPTER 3 SYSTEM DATA PROGRAMMING Centralized Billing-CCIS NEAX2000 IVS2 CCIS System Manual ND-70918 (E), Issue 1.0 Page 159 DESCRIPTION DATA Do not provide the system with Built-in SMDR on MP card.(1) (2)800 1 : Not provided (AP00 is effective) Provide the system with Centralized Billing-CCIS for Center Office.(1) (2)368 0: Provided Do not provide the system with Centralized Billing-CCIS for Local Office.(1) (2)378 1 : Not provided Assign the second data to 1 (Distant end is a Local Office) to...
Page 173
NEAX2000 IVS2 CCIS System ManualPage 160 ND-70918 (E), Issue 1.0 CHAPTER 3 SYSTEM DATA PROGRAMMING Centralized Billing-CCIS DESCRIPTION DATA Assign the attribute data, depending on the port (Port 0-3) connected to the SMDR terminal. (For the details of commands, refer to the Command Manual.)(1) (2)See the following table. See the following table. NOTE:For the Port 1 and Port 3, data speed 9600 bps cannot be set. Assign the Charging Station Class number to each station number.(1) (2)X-XXXX: Station...
Page 174
CHAPTER 3 SYSTEM DATA PROGRAMMING Centralized Billing-CCIS NEAX2000 IVS2 CCIS System Manual ND-70918 (E), Issue 1.0 Page 161 DESCRIPTIONDATA Invalidate the data setting of Centralized Billing used for Local Office.(1) (2)XX31: Sending of billing information of C.O. outgoing calls through CCIS XX : 00-15 (Station Class No. assigned by CMD015) 1 : Sent (1) (2)XX32: Sending of billing information of Tie Line outgoing calls through CCIS XX : 00-15 (Station Class No. assigned by CMD015) 1 : Sent...
Page 175
NEAX2000 IVS2 CCIS System ManualPage 162 ND-70918 (E), Issue 1.0 CHAPTER 3 SYSTEM DATA PROGRAMMING Centralized Billing-CCIS Built-in SMDR Programming For Local Office or Tandem Office, in addition to the basic programming of Built-in SMDR, do the following programming. For details of the Built-in SMDR, refer to Feature Programming Manual. NOTE 1:When the system provides an AP00 card (CM05 Y=0 second data=04 is assigned), the Built-in SMDR cannot be provided. NOTE 2:Outgoing and tandem call records are...
Page 176
CHAPTER 3 SYSTEM DATA PROGRAMMING Centralized Billing-CCIS NEAX2000 IVS2 CCIS System Manual ND-70918 (E), Issue 1.0 Page 163 DESCRIPTIONDATA Assign the data as follows. 1st Data 2nd Data CCIS channel No. 0 (0-7) for Center Office See Example 3: Data Assignment of CMA7 YY=03, 04 on Page 176. (1) (2)YY=03 0-7: CCIS channel No. 0 : Distant end is Center Office 1 : Distant end is Local Office Assign Centralized Billing destination. See Example 3: Data Assignment of CMA7 YY=03, 04 on Page 176....
Page 177
NEAX2000 IVS2 CCIS System ManualPage 164 ND-70918 (E), Issue 1.0 CHAPTER 3 SYSTEM DATA PROGRAMMING Centralized Billing-CCIS SMDR with AP00 Programming (2) For Local Office or Tandem Office, in addition to the basic programming of SMDR with AP00, do the following programming. For details of the SMDR with AP00, refer to Feature Programming Manual. DESCRIPTION DATA Not provide the system with Built-in SMDR of MP card. NOTE:Do not assign CM40 YY=00>14 when using Built-in SMDR in Local Office of...
Page 178
CHAPTER 3 SYSTEM DATA PROGRAMMING Centralized Billing-CCIS NEAX2000 IVS2 CCIS System Manual ND-70918 (E), Issue 1.0 Page 165 DESCRIPTIONDATA Assign the data as follows. For Local Office: 1st Data 2nd Data CCIS channel No. 0 (0-7) for Center Office For Tandem Office: 1st Data 2nd Data CCIS channel No. 0 (0-7) for Center Office CCIS channel No. 1 (0-7) for Local Office See Example 3: Data Assignment of CMA7 YY=03, 04 on Page 176. (1) (2)YY=03 0-7: CCIS channel No. 0 : Distant end is Center...
Page 179
NEAX2000 IVS2 CCIS System ManualPage 166 ND-70918 (E), Issue 1.0 CHAPTER 3 SYSTEM DATA PROGRAMMING Centralized Billing-CCIS DESCRIPTION DATA Assign a Station Class number to the required station number.(1) (2)X-XXXX: Station No. 00 -15: Station Class No. Assign the data for sending the detail call information for C.O. outgoing calls through CCIS.(1) (2)XX31 XX: 00-15 (Station Class No. assigned by CMD015) 1: To send Assign the data for sending of detail call information for Tie Line outgoing calls...
Page 180
CHAPTER 3 SYSTEM DATA PROGRAMMING Centralized Billing-CCIS NEAX2000 IVS2 CCIS System Manual ND-70918 (E), Issue 1.0 Page 167 Example 1: Data Assignment of SMDR output for Center Office In a Centralized Billing Office, the following four patterns of SMDR output can be selected. (1) To SMDR 0: Sending of billing information from both a Center Office and Local Offices. (2) To SMDR 1: Sending of billing information from both a Center Office and Local Offices. (3) To SMDR 0: Sending of billing...