Page 101
NEAX2000 IVS2 CCIS System ManualPage 88 ND-70918 (E), Issue 1.0 CHAPTER 3 SYSTEM DATA PROGRAMMING No. 7 CCIS With Digital Interface DESCRIPTION DATA For North America/Other Countries: Provide the System with Call Forwarding Override-CCIS.(1) (2)371 0 : Not available 1 : Available Specify alternative routing when the out- going trunks of Tandem Office are all busy.(1) (2)372 0 : Available 1 : Not available Provide Station-to-Station Transfer over CCIS.(1) (2)253 0 : Available 1 : Not Available END...
Page 102
CHAPTER 3 SYSTEM DATA PROGRAMMING No. 7 CCIS With Digital Interface NEAX2000 IVS2 CCIS System Manual ND-70918 (E), Issue 1.0 Page 89 CCH Assignment DESCRIPTION DATA Assign an AP number to the CCH card. The AP number must match the switch settings on the CCH card. (1) (2)Y=0 04-15, 20-31: AP No. 11: CCH card Assign a CCIS channel number to each CCH card. (1) (2)YY=07 0-7: CCIS channel No. 04-15, 20-31: AP No. of the CCH card assigned by CM05 Y=0 Provide the common signaling channel and voice...
Page 103
NEAX2000 IVS2 CCIS System ManualPage 90 ND-70918 (E), Issue 1.0 CHAPTER 3 SYSTEM DATA PROGRAMMING No. 7 CCIS With Digital Interface DESCRIPTION DATA Assign a Originating Point Code (OPC) to each CCIS channel number. NOTE:The Originating Point Code is used to designate an originating office in the No. 7 CCIS network. A single OPC should be assigned to all CCIS channels provided in the same system. (1) (2)YY=01 0-7: CCIS channel No. 00001-16367: Originating Point Code Assign a Destination Point...
Page 104
CHAPTER 3 SYSTEM DATA PROGRAMMING No. 7 CCIS With Digital Interface NEAX2000 IVS2 CCIS System Manual ND-70918 (E), Issue 1.0 Page 91 Numbering Plan Assignment For open numbering system DESCRIPTION DATA Assign the access code for LCR Group 0- 3. (1) (2)Y=0-3 Number Plan Group 0-3 X-XXXX: Access Code A126: LCR Group 0 A127: LCR Group 1 A128: LCR Group 2 A129: LCR Group 3 Assign an Area Code Development Pattern number to each LCR Group. (1) (2)YYYY=A000 0-3: LCR Group 0-3 4000-4007: Area Code...
Page 105
NEAX2000 IVS2 CCIS System ManualPage 92 ND-70918 (E), Issue 1.0 CHAPTER 3 SYSTEM DATA PROGRAMMING No. 7 CCIS With Digital Interface DESCRIPTION DATA To delete the designated digit of an area code: (1) (2)YYYY=5000-5255 LCR Pattern No. 000-255 153: Designation of digit to be deleted 00 : No digit deletion 01-10: Leading 1-10 digits deletion CCC : No digit deletion For digit addition, designate the digits to be added. NOTE:Digits are always added in front of the number to be dialed. (1)...
Page 106
CHAPTER 3 SYSTEM DATA PROGRAMMING No. 7 CCIS With Digital Interface NEAX2000 IVS2 CCIS System Manual ND-70918 (E), Issue 1.0 Page 93 For closed numbering system DESCRIPTION DATA Assign the access code for LCR Group 3. (1) (2)Y=0-3 Number plan Group 0-3 X-XXXX: Access Code A129: LCR Group 3 When providing Centralized MAT or Number Portability, assign the access code for the number of digits of the network station number. NOTE:For Centralized MAT or Number Portability, this data must be...
Page 107
NEAX2000 IVS2 CCIS System ManualPage 94 ND-70918 (E), Issue 1.0 CHAPTER 3 SYSTEM DATA PROGRAMMING No. 7 CCIS With Digital Interface DESCRIPTION DATA To delete the designated digit of an area code: (1) (2)YYYY=5000-5255 LCR Pattern No. 000-255 153: Designation of digit to be deleted 00 : No digit deletion 01-10: Leading 1-8 digits deletion CCC : No digit deletion For digit addition, designate the digits to be added. NOTE:Digits are always added in front of the number to be dialed. (1)...
Page 108
CHAPTER 3 SYSTEM DATA PROGRAMMING No. 7 CCIS With Digital Interface NEAX2000 IVS2 CCIS System Manual ND-70918 (E), Issue 1.0 Page 95 Inter-Tenant Connection Assignment DESCRIPTION DATA Assign the Tenant number to each station. NOTE:When making a link with the IMX, Tenant number should be assigned as 01-63. 00 is not used. (1) (2)YY=04 X-XXXXXXXX: Station No. 00-63: Tenant No. 00-63 01 : Tenant No. 01 Assign the Tenant number to each trunk. NOTE:When making a link with the IMX, Tenant...
Page 109
NEAX2000 IVS2 CCIS System ManualPage 96 ND-70918 (E), Issue 1.0 CHAPTER 3 SYSTEM DATA PROGRAMMING No. 7 CCIS With Digital Interface Example 1: Inter-Tenant Connection for Station-to-Station Calling. For the inter-tenant connection between Sta. A and Sta. B, the data assignment at Office B is as follows. NOTE:The inter-tenant connection between Trunk B and Sta. B (CM63 Y=2) is ineffective. Command Code 1st Data 2nd Data CM63 Y=1 01 02 01: Tenant No. of Calling Station (Sta. A) 02: Tenant No. of Called...
Page 110
CHAPTER 3 SYSTEM DATA PROGRAMMING No. 7 CCIS With Digital Interface NEAX2000 IVS2 CCIS System Manual ND-70918 (E), Issue 1.0 Page 97 Example 2: Inter-Tenant Connection for Incoming Call Termination. For the inter-tenant connection between Trunk C (Office A) and Sta. B (Office B), the data assignment at Office B is as follows. NOTE:The inter-tenant restriction between Trunk B and Sta. B (CM63 Y=2) is ineffective. Command Code 1st Data 2nd Data CM63 Y=2 01 02 01: Tenant No. of Called Station (Sta....