NEAX2000 IVS2 CCIS System ManualPage 58 ND-70918 (E), Issue 1.0 CHAPTER 2 INSTALLATION Required Equipment Ta b l e 2 - 2 shows the equipment and cables required when providing No. 7 CCIS with analog interface. Table 2-2 Required Equipment and Cable for No. 7 CCIS with Analog Interface EQUIPMENT/ CABLEDESCRIPTION QUANTITY REMARKS PN-2LDT or PN-2ODTLoop Dial Trunk or 2-wire E&M/4-wire E&M Trunk1-128 PN-SC00 Common Channel Handler Card 1-8 PN-AP00-B Application Processor Card for Centralized...
Page 72
CHAPTER 2 INSTALLATION Installation Procedure NEAX2000 IVS2 CCIS System Manual ND-70918 (E), Issue 1.0 Page 59 INSTALLATION PROCEDURE No. 7 CCIS with Digital Interface Install the equipment according to the procedures shown in Figure 2-3. For installation of the PBX, refer to the Installation Procedure Manual. Figure 2-3 Installation Procedure for No. 7 CCIS with Digital Interface START MOUNTING CCH CARD MOUNTING EXPMEM CARD SELECTION OF PLO IN MOUNTING DTI CARD MOUNTING AP00 CARD MOUNTING CONN...
Page 73
NEAX2000 IVS2 CCIS System ManualPage 60 ND-70918 (E), Issue 1.0 CHAPTER 2 INSTALLATION Installation Procedure Mounting DTI Card (1) Before mounting the DTI (PN-24DTA-C/PN-30DTC-A) card, set the MB switch to UP position, and set the other switches to appropriate position. See CHAPTER 4 on Page 259. (2) Mount the DTI card in the following AP slot in PIM0 through PIM7. PIM0: AP00-AP10 PIM1-7: AP00-AP11 NOTE:The DTI card (DTI0, DTI1) which sends a clock signal to PLO of the MP card must be mounted in the...
Page 74
CHAPTER 2 INSTALLATION Installation Procedure NEAX2000 IVS2 CCIS System Manual ND-70918 (E), Issue 1.0 Page 61 Mounting CCH Card (1) Before mounting the CCH (PN-SC00) card, set the MB switch to UP position, and set the other switches to appropriate position. See CHAPTER 4 on Page 259. (2) Mount the CCH card in the following AP slot of PIM0 through PIM7. PIM0: AP00-AP10 PIM1-7: AP00-AP11 (3) After mounting the card, set the MB switch to DOWN position to put the card in service. AT T E N T I O...
Page 75
NEAX2000 IVS2 CCIS System ManualPage 62 ND-70918 (E), Issue 1.0 CHAPTER 2 INSTALLATION Installation Procedure Mounting EXPMEM Card When billing information of more than 1600 calls is needed, install the EXPMEM (PZ-M537) card as detailed below. (1) Confirm the correct switch setting. See CHAPTER 4 on Page 259. (2) Mount the EXPMEM card on the AP00 card. (3) Mount the AP00 card into AP slots. (See Mounting AP00 Card on Page 63.) AT T E N T I O NContents Static Sensitive Handling Precautions Required
Page 76
CHAPTER 2 INSTALLATION Installation Procedure NEAX2000 IVS2 CCIS System Manual ND-70918 (E), Issue 1.0 Page 63 Mounting AP00 Card (1) Before mounting the AP00 (PN-AP00-B) card, set the MB switch to UP position, and set the other switches to appropriate position. See CHAPTER 4 on Page 259. (2) Mount the AP00 card in any one of AP slot on each PIM. (3) After mounting the card, set the MB switch to the DOWN position to put the card in service. AT T E N T I O NContents Static Sensitive Handling...
Page 77
NEAX2000 IVS2 CCIS System ManualPage 64 ND-70918 (E), Issue 1.0 CHAPTER 2 INSTALLATION Installation Procedure Mounting CONN Card When providing the CONN (PZ-M542/M557) card to connect a coaxial cable for 30-DTI card, do the following installation. (1) Confirm the correct switch settings. See CHAPTER 4 on Page 259. (2) Mount the CONN card on LTC connector of each PIM. For details, refer to the Installation Procedure Manual. AT T E N T I O NContents Static Sensitive Handling Precautions Required
Page 78
CHAPTER 2 INSTALLATION Installation Procedure NEAX2000 IVS2 CCIS System Manual ND-70918 (E), Issue 1.0 Page 65 Mounting M10 Card (1) Confirm the correct switch settings. See CHAPTER 4 on Page 259. (2) Mount the M10 card in any one of LT slot on each PIM. AT T E N T I O NContents Static Sensitive Handling Precautions Required
Page 79
NEAX2000 IVS2 CCIS System ManualPage 66 ND-70918 (E), Issue 1.0 CHAPTER 2 INSTALLATION Installation Procedure Selection of PLO in MP Card (1) Confirm the correct switch settings. See CHAPTER 4 on Page 259. (2) Mount the MP (PN-CP14) card in the MP slot of PIM0. AT T E N T I O NContents Static Sensitive Handling Precautions Required
Page 80
CHAPTER 2 INSTALLATION Installation Procedure NEAX2000 IVS2 CCIS System Manual ND-70918 (E), Issue 1.0 Page 67 Cable Connection via MDF When using a twisted-pair cable, connect the cable to a CSU via the MDF as shown in Figure 2-4. Figure 2-4 DTI Cable Connection via MDF CSU MDF LTC0/LTC1/LTC2/LTC3 CONNECTORTWISTED-PAIR CABLE BWBPBX (SHIELD TYPE) MAX. 200 m (655 ft.) .......... 24-DTI MAX. 400 m (1310 ft.)......... 30-DTI 24-DTI 30-DTI