 NEAX2000 IVS2 CCIS System ManualPage 58  ND-70918 (E), Issue 1.0
CHAPTER 2  INSTALLATION
Required Equipment
Ta b l e  2 - 2 shows the equipment and cables required when providing No. 7 CCIS with analog
interface.
Table 2-2  Required Equipment and Cable for No. 7 CCIS with Analog Interface
EQUIPMENT/
CABLEDESCRIPTION QUANTITY REMARKS
 PN-2LDT or 
PN-2ODTLoop Dial Trunk or
2-wire E&M/4-wire E&M Trunk1-128
 PN-SC00 Common Channel Handler Card 1-8
 PN-AP00-B Application Processor Card for 
Centralized...

Page 72

CHAPTER 2  INSTALLATION
Installation Procedure
NEAX2000 IVS2 CCIS System Manual    
ND-70918 (E), Issue 1.0   Page 59
INSTALLATION PROCEDURE
No. 7 CCIS with Digital Interface
Install the equipment according to the procedures shown in Figure 2-3.
For installation of the PBX, refer to the Installation Procedure Manual.
Figure 2-3  Installation Procedure for No. 7 CCIS with Digital Interface
START
MOUNTING CCH CARD
MOUNTING EXPMEM CARD
SELECTION OF PLO IN
MOUNTING DTI CARD
MOUNTING AP00 CARD
MOUNTING CONN...

Page 73

 NEAX2000 IVS2 CCIS System ManualPage 60  ND-70918 (E), Issue 1.0
CHAPTER 2  INSTALLATION
Installation Procedure
Mounting DTI Card
(1) Before mounting the DTI (PN-24DTA-C/PN-30DTC-A) card, set the MB 
switch to UP position, and set the other switches to appropriate position.
See CHAPTER 4 on Page 259.
(2) Mount the DTI card in the following AP slot in PIM0 through PIM7.
PIM0: AP00-AP10
PIM1-7: AP00-AP11
NOTE:The DTI card (DTI0, DTI1) which sends a clock signal to PLO of the MP card must be
mounted in the...

Page 74

CHAPTER 2  INSTALLATION
Installation Procedure
NEAX2000 IVS2 CCIS System Manual    
ND-70918 (E), Issue 1.0   Page 61
Mounting CCH Card
(1) Before mounting the CCH (PN-SC00) card, set the MB switch to UP 
position, and set the other switches to appropriate position.
See CHAPTER 4 on Page 259.
(2) Mount the CCH card in the following AP slot of PIM0 through PIM7.
PIM0: AP00-AP10
PIM1-7: AP00-AP11
(3) After mounting the card, set the MB switch to DOWN position to put the card in service.
AT T E N T I O...

Page 75

 NEAX2000 IVS2 CCIS System ManualPage 62  ND-70918 (E), Issue 1.0
CHAPTER 2  INSTALLATION
Installation Procedure
Mounting EXPMEM Card
When billing information of more than 1600 calls is needed, install the
EXPMEM (PZ-M537) card as detailed below.
(1) Confirm the correct switch setting. See CHAPTER 4 on Page 259.
(2) Mount the EXPMEM card on the AP00 card.
(3) Mount the AP00 card into AP slots. (See Mounting AP00 Card on Page 63.)
AT T E N T I O NContents
Static Sensitive
Handling
Precautions Required 

Page 76

CHAPTER 2  INSTALLATION
Installation Procedure
NEAX2000 IVS2 CCIS System Manual    
ND-70918 (E), Issue 1.0   Page 63
Mounting AP00 Card
(1) Before mounting the AP00 (PN-AP00-B) card, set the MB switch to UP 
position, and set the other switches to appropriate position.
See CHAPTER 4 on Page 259.
(2) Mount the AP00 card in any one of AP slot on each PIM.
(3) After mounting the card, set the MB switch to the DOWN position to put the card in service.
AT T E N T I O NContents
Static Sensitive
Handling...

Page 77

 NEAX2000 IVS2 CCIS System ManualPage 64  ND-70918 (E), Issue 1.0
CHAPTER 2  INSTALLATION
Installation Procedure
Mounting CONN Card
When providing the CONN (PZ-M542/M557) card to connect a coaxial cable
for 30-DTI card, do the following installation.
(1) Confirm the correct switch settings.
See CHAPTER 4 on Page 259.
(2) Mount the CONN card on LTC connector of each PIM.
For details, refer to the Installation Procedure Manual.
AT T E N T I O NContents
Static Sensitive
Handling
Precautions Required 

Page 78

CHAPTER 2  INSTALLATION
Installation Procedure
NEAX2000 IVS2 CCIS System Manual    
ND-70918 (E), Issue 1.0   Page 65
Mounting M10 Card
(1) Confirm the correct switch settings.
See CHAPTER 4 on Page 259.
(2) Mount the M10 card in any one of LT slot on each PIM.
AT T E N T I O NContents
Static Sensitive
Handling
Precautions Required 

Page 79

 NEAX2000 IVS2 CCIS System ManualPage 66  ND-70918 (E), Issue 1.0
CHAPTER 2  INSTALLATION
Installation Procedure
Selection of PLO in MP Card
(1) Confirm the correct switch settings.
See CHAPTER 4 on Page 259.
(2) Mount the MP (PN-CP14) card in the MP slot of PIM0.
AT T E N T I O NContents
Static Sensitive
Handling
Precautions Required 

Page 80

CHAPTER 2  INSTALLATION
Installation Procedure
NEAX2000 IVS2 CCIS System Manual    
ND-70918 (E), Issue 1.0   Page 67
Cable Connection via MDF
When using a twisted-pair cable, connect the cable to a CSU via the MDF as shown in Figure 2-4.
Figure 2-4  DTI Cable Connection via MDF
CSU MDF
LTC0/LTC1/LTC2/LTC3 CONNECTORTWISTED-PAIR
CABLE BWBPBX
(SHIELD TYPE)
MAX. 200 m (655 ft.) .......... 24-DTI
MAX. 400 m (1310 ft.)......... 30-DTI 24-DTI
30-DTI 