    							NDA-30026   Revision 6 Appendix Page 9
    Medical Center System Operations Manual - JAVA Edition
    Error and User 
    Interface 
    MessagesThis section contains a list of error messages that might appear during some beeper 
    operations.
    Beeper Interface Not Installed - The beeper interface software that would 
    handle the communications between UAP Applications and the local beeper 
    terminal is either not installed or has not been installed properly.
    Beeper Interface Offline - The beeper terminal is not communicating with the 
    beeper interface software or in not active. First check that the beeper interface 
    is active, then check the physical connection between the UAP’s 
    communication port and the beeper terminal’s communication port. If the error 
    continues to occur, check the beeper interface configuration, and ensure that the 
    communication device port is accurate.
    Queue Status Error [x] - While attempting to send an IPC message to the beeper 
    interface, a message queue error occurred. The value [x] is the system error that 
    occurred. This error occurs very infrequently. However, in the event that this 
    error does occur, take note of the error number, and contact the site technician. 
    Restarting the beeper interface and/or the MCS menu process should correct 
    this error condition.
    Unable to send beeper message - The MCS menu process was unable to send 
    an IPC message to the beeper interface. This error is usually a result of the 
    beeper interface terminating abnormally. Make sure that the beeper interface 
    software is active. If the software is active, this message indicates that other 
    message interface problems are occurring in the system. Check the APM error 
    log.
    Failure: Timed Out - The MCS menu process timed-out waiting for a response 
    from the beeper interface software. If the beeper interface appears to be active 
    and this message occurs frequently, you need to increase the response timer.
    Failure: Out-of-service - The beeper interface timed-out waiting for an 
    acknowledgment from the beeper terminal. If the beeper terminal appears to be 
    functioning properly and the error occurs frequently, you need to increase the 
    response timer between the beeper interface software and the beeper terminal.  
    						
    							Appendix Page 10 NDA-30026   Revision 6
    Medical Center System Operations Manual - JAVA Edition
    Interface 
    ConfigurationA special UNIX user account, bpradm, allows access to configurable interface 
    data. This section presents most of the screens that you might need to access during 
    installation and support of the interface.
    Main Menu
    After logging into the UNIX system with the user account name bpradm, the 
    following menu displays.
    Figure A-8   Beeper Interface Administration Menu
    In the figure above, the interface status is active. When the status is active, you can 
    start and stop the interface from this menu as well as view some of the log files and 
    set the interface configurable data.
         
          
           
          
           
          
         
         
        
         
    Beeper Interface Administration Menu
    Interface Status: Active    Version: 1.0
    Options
    View Log File
    Erase Log File
    Initialize Interface
    Terminate Interface
    Configuration
    UNIX
    Logout 
    						
    							NDA-30026   Revision 6 Appendix Page 11
    Medical Center System Operations Manual - JAVA Edition
    Configuration 
    MenuSelecting Configuration displays the following menu of options:
    Figure A-9   Configuration Menu
    Valid commands or options are indicated by the bold underlined letters. Each 
    option is discussed in detail below.
    Configuration Files
    To modify the configuration files enter “C” at the Enter Option prompt. All the 
    configuration files, will be displayed as shown in the following window:
    Figure A-10   Configuration Files
    You will rarely need to change this information. These files indicate the location 
    of configuration data. 
         
          
           
          
           
          
         
         
        
         
          
    Interface Configuration Menu
    Modify C
    onfiguration Files
    Modify M
    isc Parameters
    Modify P
    ort Parameters
    Modify T
    imer Parameters
    S
    ave Configuration
    Q
    uit to Main Menu
    Enter Option:  [ ]
         
          
           
          
           
          
         
         
        
         
          
    Enter transaction log file name
    (/oai/app/beeper/log/trans.log) :
    Enter beeper log file name
    (/oai/app/beeper/log/beeper.log) :
    Enter fifo device name
    (/oai/app/beeper/beeper.fifo) :
    Enter beeperq executable name
    (/oai/app/beeper/bin/beeperq) :
    Enter beeperq log file name
    (/oai/app/beeper/log/beeperrq.log) :
    Enter beeperq qkey filename
    (oai/app/beeper/cfg/config) : 
    						
    							Appendix Page 12 NDA-30026   Revision 6
    Medical Center System Operations Manual - JAVA Edition
    Once the configuration file update is complete, you will be returned to the 
    Configuration Main Menu. 
    Miscellaneous Parameters
    To modify the miscellaneous parameters enter “M” at the Enter Option prompt. 
    The window shown below will be displayed. Once you have entered the parameters 
    you will be returned to the Configuration Main Menu. 
    Figure A-11   Misc Parameters Window
    These miscellaneous parameters are vendor specific. In most cases the default 
    values should work. 
         
          
           
          
           
          
         
         
        
         
          
    Enter log level value (9) :
    Enter modem dial number ():
    Enter pager name (PGI) :
    Enter pager password (000000): 
    						
    							NDA-30026   Revision 6 Appendix Page 13
    Medical Center System Operations Manual - JAVA Edition
    Port Parameters
    To modify the port parameters enter “P” at the Enter Option prompt. The window 
    shown below will be displayed. 
    Figure A-12   Port Parameters Window
    The port parameters are also vendor specific. In most cases the default values 
    should work. Once you have entered the parameters you will be returned to the 
    Configuration Main Menu. 
    Timer Parameters
    To modify the timer parameters enter “T” at the Enter Option prompt. The timer 
    parameters, will be displayed as shown in the window below. 
    Figure A-13   Timer Parameters Window      
          
           
          
           
          
         
         
        
         
          
    Enter serial port device name (/dev/tty2a) :
    (9600-8-e-1)
    Enter Speed of port (9600) :
    Enter Data size (8/7) of port (8) :
    Enter Parity (n/o/e) of port (e) :
    Enter Stop Bits of port (1) :
         
          
           
          
           
          
         
         
        
         
          
    Enter cr wait timer value (2 sec) :
    Enter ID wait timer value (10 sec) :
    Enter transaction wait timer value (10 sec): 
    Enter send wait timer value (30 sec) :
    Enter cr retry value (5 times) : 
    Enter transaction retry valu (3 times) : 
    						
    							Appendix Page 14 NDA-30026   Revision 6
    Medical Center System Operations Manual - JAVA Edition
    The timer parameters relate to the TAP message format. These timing variables 
    might require coordination with the vendor specific beeper terminal data. Once you 
    have entered the parameters you will be returned to the Configuration Main 
    Menu.
    Viewing Transaction Log Files
    You can view the current transaction log by selecting View Log File option from 
    the main screen. Three log files are saved by the beeper interface: One traces 
    transaction messages between OAI application and the beeper interface, a second 
    traces transaction messages between the beeper interface and the beeper terminal 
    interface, and the third is a transaction only file. The third transaction log file will 
    contain the results of each beeper request received by the interface. The disposition 
    of each request is logged in this file - success or failure. Below is an illustration of 
    the View Log File Menu:
    Figure A-14   View Log File Menu
    View Log File Menu
    View Beeper Log File
    View BeeperQ Log File
    View Beeper Transaction Log File
    Main Menu
    Enter Option:  [ ] 
    						
    							NDA-30026   Revision 6 Appendix Page 15
    Medical Center System Operations Manual - JAVA Edition
    Select the log file that you want to view. A screen similar to the following displays. 
    You can use PgUp and PgDn as well as command line options that are listed across 
    the bottom of the display. These options are described below:
    Figure A-15   Beeper Transaction Log
    The AutoScroll feature allows you to view the file in real-time. As new messages 
    are received, they display at the bottom of the screen. The other command line 
    options allow you to move within the file, print a screen display or the complete 
    file, or execute an external UNIX command.
     Beeper Transaction Log                                 Tue Aug 22 1BEGINNING OF DATA
    08/10-14:24:35   REPLY COMPLETE [ :No error ]
    08/10-16:11:56   REPLY COMPLETE [ :No error ]
    08/11-13:07:52   REPLY COMPLETE [ :No error ]
    END OF DATA
           Search    Top    Bottom    Command    Print    AutoScroll     
    						
    							Medical Center System Operations Manual - JAVA Edition
    Appendix Page 16 NDA-30026   Revision 6
    This Page Left Blank. 
    						