NECA 340-414-220 Revision 2.0 Page 1 of 2
MCU 5000A Multipoint Control Unit SPR-020
MAXIMUM TALKER SETTING
VOICE RELATED
SUMMARY:  
Restrict the number of the talkers who are allowed to talk simultaneously on a 
voice channel.
STEP PROCEDURE 
1 Enter the following command.
SSPR__ n1 =  x1 __n2 = x2 __ … ni = xi … ø
ni:
System parameter address53H
x
i:
System parameter values See below:
[1] System parameter values on setting the number of talkers.  The factory shipment value 
is 00H
.
SYSTEM...

Page 292

Page 2 of 2 NECA 340-414-220 Revision 2.0
SPR-020 MCU 5000A Multipoint Control Unit
This page is for your notes. 

Page 293

NECA 340-414-220 Revision 2.0 Page 1 of 2
MCU 5000A Multipoint Control Unit SPR-021
TALKER DETECTION (MCON) SETTING
MULTIPOINT TELECONFERENCE RELATED
SUMMARY: 
Set the talker detection to ON or OFF when MCON is executed.
STEP PROCEDURE 
1 Enter the following command.
SSPR__ n1 =  x1 __n2 = x2 __ … ni = xi … ¿
ni:
System parameter address70H
x
i:
System parameter values See below:
[1] System parameter values on setting for talker detection.  The factory shipment value 
is 00H
.
SYSTEM PARAMETER TALKER...

Page 294

Page 2 of 2 NECA 340-414-220 Revision 2.0
SPR-021 MCU 5000A Multipoint Control Unit
This page is for your notes. 

Page 295

NECA 340-414-220 Revision 2.0 Page 1 of 2
MCU 5000A Multipoint Control Unit SPR-022
AREA NAME DELETION SETTING
MULTIPOINT TELECONFERENCE RELATED
SUMMARY: 
Set the deletion of area name to ON or OFF when MDSC is executed.
STEP PROCEDURE 
1 Enter the following command.
SSPR__ n1 =  x1 __n2 = x2 __ … ni = xi … ¿
ni:
System parameter address73H
x
i:
System parameter values See below:
[1] System parameter values on setting the deletion of area name.  The factory shipment 
value is 00H
.
SYSTEM PARAMETER AREA...

Page 296

Page 2 of 2 NECA 340-414-220 Revision 2.0
SPR-022 MCU 5000A Multipoint Control Unit
This page is for your notes. 

Page 297

NECA 340-414-220 Revision 2.0 Page 1 of 2
MCU 5000A Multipoint Control Unit SPR-023
H.242 CAPABILITY SWITCHING ACTION SETTING
MULTIPOINT TELECONFERENCE RELATED 
SUMMARY:
Set whether or not to perform ITU-T Recommendation H.242 defined capability 
switching to and from connecting terminal (VL 5000).  When the capability 
switching is performed, it is necessary to confirm all the participating terminals 
have the same capability.  Terminals having different capabilities cannot 
participate in the...

Page 298

Page 2 of 2 NECA 340-414-220 Revision 2.0
SPR-023 MCU 5000A Multipoint Control Unit
This page is for your notes. 

Page 299

NECA 340-414-220 Revision 2.0 Page 1 of 2
MCU 5000A Multipoint Control Unit SPR-024
TALKER DETECTION (ECON) SETTING
MULTIPOINT TELECONFERENCE RELATED
SUMMARY:
Set the talker detection to ON or OFF when ECON is executed.
STEP PROCEDURE 
1 Enter the following command.
SSPR__ n1 =  x1 __n2 = x2 __ … ni = xi … ¿
ni:
System parameter address88H
x
i:
System parameter values See below:
[1] System parameter values on setting the talker detection.  The factory shipment value 
is 00H
.
SYSTEM PARAMETER TALKER...

Page 300

Page 2 of 2 NECA 340-414-220 Revision 2.0
SPR-024 MCU 5000A Multipoint Control Unit
This page is for your notes. 