Page 341
NECA 340-414-220 Revision 2.0 Page 1 of 2 MCU 5000A Multipoint Control Unit SPR-042 LOW SPEED DATA (LSD) MODE SETTING TERMINAL MODE RELATED SUMMARY: Set the Low Speed Data (LSD) mode. STEP PROCEDURE 1Note: MCU 5000A does not support LSD mode. Be sure, therefore, to set all LSD mode settings to OFF (0000H) . If change is necessary for any reason, follow the steps described below. Enter the following command. SSPR__ n1 = x1 __n2 = x2 __ … ni = xi … ¿ ni: System parameter address12AH and 12BH [1]...
Page 342
Page 2 of 2 NECA 340-414-220 Revision 2.0 SPR-042 MCU 5000A Multipoint Control Unit LOW SPEED DATA (LSD) MODE SETTING TERMINAL MODE RELATED STEP PROCEDURE SYSTEM PARAMETER LSD MODE SETTING ADDRESS 12BHADDRESS 12AH 00H 00H OFF 2 Verify that the normal response is displayed with “OK ”. If YES , go to Step 3 . If NO , go to Step 1 . 3 End of procedure.
Page 343
NECA 340-414-220 Revision 2.0 Page 1 of 2 MCU 5000A Multipoint Control Unit SPR-043 HIGH SPEED DATA (HSD) MODE SETTING TERMINAL MODE RELATED SUMMARY: Set the High Speed Data (HSD) mode. STEP PROCEDURE Note: MCU 5000A does not support HSD in MCON mode. 1 Enter the following command. SSPR__ n 1 = x1 __n2 = x2 __ … ni = xi … ¿ n i: System parameter address12CH and 12DH [1] Addresses (hexadecimal values) on setting the HSD mode. The HSD mode is set in hexadecimal values by dividing the 32 bits (b0 to...
Page 344
Page 2 of 2 NECA 340-414-220 Revision 2.0 SPR-043 MCU 5000A Multipoint Control Unit HIGH SPEED DATA (HSD) MODE SETTING TERMINAL MODE RELATED STEP PROCEDURE SYSTEM PARAMETER HSD MODE SETTING ADDRESS 12FHADDRESS 12EHADDRESS 12DHADDRESS 12CH 00H 00H 00H 00H OFF 00H 00H 02H 00H 64 kb/s is ON. 00H 00H 04H 00H 128 kb/s is ON. 00H 00H 08H 00H 192 kb/s is ON. 00H 00H 10H 00H 256 kb/s is ON. 00H 00H 20H 00H 320 kb/s is ON 00H 00H 40H 00H 384 kb/s is ON. 00H 00H 80H 00H 512 kb/s (R) is ON. 00H 01H 00H 00H 768...
Page 345
NECA 340-4 14- 22 0 Revisio n 2.0 Page 1 o f 2 MCU 5000A Multipoint Control U nit SPR-044 MLP MODE SETTING ADDRESS MLP MODE x
Page 346
Page 2 of 2 NECA 340-414-220 Revision 2.0 SPR-044 MCU 5000A Multipoint Control Unit MLP MODE SETTING TERMINAL MODE RELATED STEP PROCEDURE SYSTEM PARAMETER MLP MODE SETTING ADDRESS 131HADDRESS 130H 00H 00H OFF 00H 02H MLP-4K is ON. 00H 04H MLP-6.4K is ON. 2 Verify that the normal response is displayed with “OK ”. If YES , go to Step 3 . If NO , go to Step 1 . 3 End of procedure.
Page 347
NECA 340-4 14- 22 0 Revisio n 2.0 Page 1 o f 2 MCU 5000A Multipoint Control U nit SPR-045 NETWORK CLASSIFIC ATION MODE SETTING ADDRESS NETWORK CLASSIFICAT IO N MODE x
Page 348
Page 2 of 2 NECA 340-414-220 Revision 2.0 SPR-045 MCU 5000A Multipoint Control Unit NETWORK CLASSIFICATION MODE SETTING TERMINAL MODE RELATED STEP PROCEDURE 2 Verify that the normal response is displayed with “OK ”. If YES , go to Step 3 . If NO , go to Step 1 . 3 End of procedure.
Page 349
NECA 340-414-220 Revision 2.0 Page 1 of 2 MCU 5000A Multipoint Control Unit SPR-047 MBE MODE SETTING TERMINAL MODE RELATED SUMMARY: MCU 5000A uses MBE command to utilize NECs original expansion devices. STEP PROCEDURE Note: Set the MBE mode to ON (01H 00H) as a general rule. If change is necessary for any reason, follow the steps described below. 1 Enter the following command. SSPR__ n1 = x1 __n2 = x2 __ … ni = xi … ¿ ni: System parameter address136H and 137H [1] Addresses (hexadecimal values) in...
Page 350
Page 2 of 2 NECA 340-414-220 Revision 2.0 SPR-047 MCU 5000A Multipoint Control Unit MBE MODE SETTING TERMINAL MODE RELATED STEP PROCEDURE 2 Verify that the normal response is displayed with “OK ”. If YES , go to Step 3 . If NO , go to Step 1 . 3 End of procedure.