Home > NEC > Communications System > NEC Mcu 5000a Multipoint Control Unit Equipment Manual

NEC Mcu 5000a Multipoint Control Unit Equipment Manual

Here you can view all the pages of manual NEC Mcu 5000a Multipoint Control Unit Equipment Manual. The NEC manuals for Communications System are available online for free. You can easily download all the documents as PDF.

Page 331

NECA 340-414-220 Revision 2.0 Page 1 of 2
MCU 5000A Multipoint Control Unit SPR-038
MBE MESSAGE (VIDEO) CAPABILITY SETTING
TERMINAL CAPABILITY RELATED
SUMMARY: 
Set the expansion video capability of connecting CODEC (VL 5000).
STEP PROCEDURE 
Note:
Use the MBE message (video) capability with the factory shipment value (04H 00H
).  If 
change is necessary for any reason, follow the steps described below.
1 Enter the following command.
SSPR__ n1 =  x1 __n2 = x2 __ … ni = xi … ¿
ni:
System parameter...

Page 332

Page 2 of 2 NECA 340-414-220 Revision 2.0
SPR-038 MCU 5000A Multipoint Control Unit
MBE MESSAGE (VIDEO) CAPABILITY SETTING
TERMINAL CAPABILITY RELATED
STEP PROCEDURE 
SYSTEM PARAMETER
MBE MESSAGE (VIDEO) CAPABILITY 
ADDRESS
11 D HADDRESS
11 C H
00H 00H OFF
00H 01H PTY is ON.
00H 02H PTY + FULL are ON.
00H 04H PTY + FULL + VSP are ON.
Note:
PTY detects a parity error and performs Demand Refresh on  its occurrence.
FULL: NTSC full resolution mode 
VSP: dual screen multiplex mode
2 Verify that the normal...

Page 333

NECA 340-414-220 Revision 2.0 Page 1 of 2
MCU 5000A Multipoint Control Unit SPR-039
AUDIO MODE SETTING
TERMINAL MODE RELATED
SUMMARY: 
Set audio mode.  If all the terminal CODECs (VL 5000s) are equipped with SB-
ADPCM audio CODEC (7 kHz band) features, set the audio mode to “G.722 
mode 2 (P×64k network)” or “G.722 mode 3 (p×56k network)”.  If not, set it to 
“µ -LAW and OF” and refrain from setting other values.
STEP PROCEDURE 
1 Enter the following command.
SSPR__ n1 =  x1 __n2 = x2 __ … ni = xi … ¿...

Page 334

Page 2 of 2 NECA 340-414-220 Revision 2.0
SPR-039 MCU 5000A Multipoint Control Unit
AUDIO MODE SETTING
TERMINAL MODE RELATED
STEP PROCEDURE 
SYSTEM PARAMETER
AUDIO MODE CAPABILITY
ADDRESS
123HADDRESS
122HADDRESS
121HADDRESS
120H
00H 00H 00H 04Hm-law, OU is ON.
00H 00H 00H 08Hm-law, OF (u7) is ON.
00H 00H 00H 10H G.722 mode 1 is ON.
00H 00H 00H 20H G.722 mode 2 is ON.
00H 00H 00H 40H G.722 mode 3 is ON.
00H 04H 00H 00Hm-law, OF (u6) is ON.
40H 00H 00H 00H Audio OFF, U is ON.
80H 00H 00H 00H Audio OFF, F...

Page 335

NECA 340-414-220 Revision 2.0 Page 1 of 4
MCU 5000A Multipoint Control Unit SPR-040
TRANSFER RATE MODE SETTING
TERMINAL MODE RELATED
SUMMARY:
Set the transfer rate for terminal.
STEP PROCEDURE 
Note:
If rate is specified when setting up the multipoint teleconference by MCON or ECON 
command, the MCON or ECON command specified rate is set.
1 Enter the following command.
SSPR__ n1 =  x1 __n2 = x2 __ … ni = xi … ¿
ni:
System parameter address124H 
and 127H
[1] Addresses (hexadecimal values) on setting the...

Page 336

Page 2 of 4 NECA 340-414-220 Revision 2.0
SPR-040 MCU 5000A Multipoint Control Unit
TRANSFER RATE MODE SETTING
TERMINAL MODE RELATED
STEP PROCEDURE 
x
i:
System parameter values See below:
[1] System parameter values on setting the transfer rate mode for the addresses 124H to 
127H.
The factory shipment value for the system parameter is 00H 02H 00H 00H
.
SYSTEM PARAMETER
Transfer rate mode 
ADDRESS
127HADDRESS
126HADDRESS
125HADDRESS
124H
00H 00H 00H 01H 64 kb/s is ON.
00H 00H 00H 02H 64 kb/s x 2 is ON....

Page 337

NECA 340-414-220 Revision 2.0 Page 3 of 4
MCU 5000A Multipoint Control Unit SPR-040
TRANSFER RATE MODE SETTING
TERMINAL MODE RELATED
STEP PROCEDURE 
Transfer Rate Mode (+124H ~ 127H)
b7
b6b5
b4 b3 b2 b1 b0
b0 : 64 kbps              (T1/RS422/INF-H0)
b1 : 64 x 2 kbps        (T1/RS422/INS-H0)Default = 00H +124H00
0 fixed0 fixed 0 fixed0 fixed 0
0
b6 : 128 kbps             (T1/RS422)
b7 : 192 kbps             (T1/RS422)
b7
b6b5
b4 b3 b2 b1 b0
b0 : 256 kbps                   (T1/RS422)
b1 : 384 kbps...

Page 338

Page 4 of 4 NECA 340-414-220 Revision 2.0
SPR-040 MCU 5000A Multipoint Control Unit
This page is for your notes. 

Page 339

NECA 340-414-220 Revision 2.0 Page 1 of 2
MCU 5000A Multipoint Control Unit SPR-041
VIDEO MODE SETTING
TERMINAL MODE RELATED
SUMMARY:
Specify whether video mode is set or not.
STEP PROCEDURE 
Note:
Use the factory shipment value (08H 00H
) in setting the video mode as a general rule.  If 
change is necessary for any reason, follow the steps described below.
1 Enter the following command.
SSPR__ n1 =  x1 __n2 = x2 __ … ni = xi … ¿
ni:
System parameter address128H 
and 129H
[1] Addresses (hexadecimal...

Page 340

Page 2 of 2 NECA 340-414-220 Revision 2.0
SPR-041 MCU 5000A Multipoint Control Unit
VIDEO MODE SETTING
TERMINAL MODE RELATED
STEP PROCEDURE 
2 Verify that the normal response is displayed with “OK
”.
If YES
, go to Step 3
.
If NO
, go to Step 1
.
3 End of procedure. 
Start reading NEC Mcu 5000a Multipoint Control Unit Equipment Manual

Related Manuals for NEC Mcu 5000a Multipoint Control Unit Equipment Manual

All NEC manuals