Page 351
NECA 340-414-220 Revision 2.0 Page 1 of 2 MCU 5000A Multipoint Control Unit SPR-048 MBE MESSAGE (AUDIO) MODE SETTING TERMINAL MODE RELATED SUMMARY: Set expansion audio devices to be used in communication with the connecting CODECs (VL 5000s). STEP PROCEDURE Note: MCU 500A does not support MBE message (audio) mode. Be sure, therefore, to set all the system parameters to OFF (00H 00H) . If change is necessary for any reason, follow the steps described below. 1 Enter the following command. SSPR__ n1...
Page 352
Page 2 of 2 NECA 340-414-220 Revision 2.0 SPR-048 MCU 5000A Multipoint Control Unit MBE MESSAGE (AUDIO) MODE SETTING TERMINAL MODE RELATED STEP PROCEDURE 2 Verify that the normal response is displayed with “OK ”. If YES , go to Step 3 . If NO , go to Step 1 . 3 End of procedure.
Page 353
NECA 340-414-220 Revision 2.0 Page 1 of 2 MCU 5000A Multipoint Control Unit SPR-049 MBE MESSAGE (LSD2) MODE SETTING TERMINAL MODE RELATED SUMMARY: Set expansion LSD (Low Speed Data) devices to be used in communication with the connecting CODECs (VL 5000s) STEP PROCEDURE Note: MCU 5000A does not support LSD2. 1 Enter the following command. SSPR__ n1 = x1 __n2 = x2 __ … ni = xi … ¿ ni: System parameter address13AH and 13BH [1] Addresses (hexadecimal values) on setting the MBE message (LSD2) mode....
Page 354
Page 2 of 2 NECA 340-414-220 Revision 2.0 SPR-049 MCU 5000A Multipoint Control Unit MBE MESSAGE (LSD2) MODE SETTING TERMINAL MODE RELATED STEP PROCEDURE SYSTEM PARAMETER MBE MESSAGE (LSD2) MODE SETTING ADDRESS 13BHADDRESS 13AH 00H 00H OFF 00H 01H 1200 b/s is ON. 00H 04H 4800 b/s is ON. 00H 08H 9600 b/s is ON. 2 Verify that the normal response is displayed with “OK ”. If YES , go to Step 3 . If NO , go to Step 1 . 3 End of procedure.
Page 355
NECA 340-414-220 Revision 2.0 Page 1 of 2 MCU 5000A Multipoint Control Unit SPR-050 MBE MESSAGE (VIDEO) MODE SETTING TERMINAL MODE RELATED SUMMARY: Set expansion video devices to be used in communication with the connecting CODECs (VL 5000s). STEP PROCEDURE Note: Set “PTY ” and “FULL ” to OFF as a general rule. Set “VSP ” to ON when the dual screen multiplex function is used at the connecting terminals, and OFF when it is not used. 1 Enter the following command. SSPR__ n1 = x1 __n2 = x2 __ …...
Page 356
Page 2 of 2 NECA 340-414-220 Revision 2.0 SPR-050 MCU 5000A Multipoint Control Unit MBE MESSAGE (VIDEO) MODE SETTING TERMINAL MODE RELATED STEP PROCEDURE x i: System parameter values See below: [1] System parameter values on setting the MBE message (video) mode for the address 13CH and 13DH. The factory shipment value for the system parameter is 06H 00H . SYSTEM PARAMETER MBE MESSAGE (VIDEO) MODE SETTING ADDRESS 13DHADDRESS 13CH 00H 00H OFF 00H 01H PTY is ON. 00H 02H FULL is ON. 00H 03H PTY and...
Page 357
NECA 340-414-220 Revision 2.0 Page 1 of 2 MCU 5000A Multipoint Control Unit SPR-101 AUDIO CAPABILITY TERMINAL CAPABILITY RELATED RCON (H.243 mode) Group A and Group B:A: means Group A and B: means Group B. Audio Capability (A: +200H ~ +203H) (B: +260H ~ +263H) b7 b6b5 b4 b3 b2 b1 b0 b1 : m -Law, OF (F6)Default = 0AH A: +200H 0 fixed 0 fixed 0 fixed 0 fixed 1 010 fixed b6 : G.722-64k b7 : G.722-48k B: +260H b7 b6b5 b4 b3 b2 b1 b0 Default = 00H 0 fixed0 fixed 0 fixed0 fixed 0 fixed 0 fixed 0 fixed0 fixed...
Page 358
Page 2 of 2 NECA 340-414-220 Revision 2.0 SPR-101 MCU 5000A Multipoint Control Unit This page is for your notes.
Page 359
NECA 340-414-220 Revision 2.0 Page 1 of 2 MCU 5000A Multipoint Control Unit SPR-102 TRANSFER RATE CAPABILITY TERMINAL CAPABILITY RELATED Transfer Rate Capability (A: +204H ~ 207H) (B: +264H ~ +267H) b7 b6b5 b4 b3 b2 b1 b0 b0 : 64 kbps (T1/RS422/INF-H0) b1 : 64 x 2 kbps (T1/RS422/INS-H0)Default = C2 11 0 fixed0 fixed 0 fixed0 fixed 1 0 b6 : 128 kbps (T1/RS422) b7 : 192 kbps (T1/RS422) A: +204H B: +264H b7 b6b5 b4 b3 b2 b1 b0 Default = C5H 11 0 fixed0 fixed 0...
Page 360
Page 2 of 2 NECA 340-414-220 Revision 2.0 SPR-102 MCU 5000A Multipoint Control Unit This page is for your notes.