Page 301
NECA 340-414-220 Revision 2.0 Page 1 of 2 MCU 5000A Multipoint Control Unit SPR-025 TC5000 OPERATION MODE SETTING MULTIPOINT TELECONFERENCE RELATED SUMMARY: Set the following parameters of teleconference terminal (TC5000). • Simultaneous multi-way conversation • Picture switching STEP PROCEDURE 1 Enter the following command. SSPR__ n1 = x1 __n2 = x2 __ … ni = xi … ¿ ni: System parameter address8EH and 8FH [1] Addresses (hexadecimal values) on setting the TC5000 operation mode. The operation mode is...
Page 302
Page 2 of 2 NECA 340-414-220 Revision 2.0 SPR-025 MCU 5000A Multipoint Control Unit TC5000 OPERATION MODE SETTING MULTIPOINT TELECONFERENCE RELATED STEP PROCEDURE x i: System parameter values See below: [1] System parameter values on setting the TC5000 operation mode for the addresses 8EH and 8FH. The factory shipment value for the system parameter is 0000H . SYSTEM PARAMETER PICTURE SWITCHING SIMULTANEOUS TALK ADDRESS 8FHADDRESS 8EH 00H 00H Picture broadcasting of the specified terminal which is...
Page 303
NECA 340-414-220 Revision 2.0 Page 1 of 4 MCU 5000A Multipoint Control Unit SPR-026 PICTURE SWITCHING TIMERS 1 TO 4 SETTING PICTURE RELATED SUMMARY:Set the timing in picture switching. STEP PROCEDURE Note: Set the standard value for every communication rate. A communication rate using a shorter timer is more likely to cause picture disturbances. The standard value is a value capable of reducing picture disturbances to a level compatible with practical utility, with only a very few picture...
Page 304
Page 2 of 4 NECA 340-414-220 Revision 2.0 SPR-026 MCU 5000A Multipoint Control Unit PICTURE SWITCHING TIMERS 1 TO 4 SETTING PICTURE RELATED STEP PROCEDURE LINE BIT RATEADDRESS TIMER 1 TIMER 2 TIMER 3 TIMER 4 64 kb/s×2 (56 kb/s×2) 180H 181H 182H 183H 128 kb/s (112 kb/s) 184H 185H 186H 187H 192 kb/s (168 kb/s) 188H 189H 18AH 18BH 256 kb/s (224 kb/s) 18CH 18DH 18EH 18FH 384 kb/s (336 kb/s) 194H 195H 196H 197H 512 kb/s (448 kb/s) 190H 191H 192H 193H 768 kb/s (672 kb/s) 198H 199H 19AH 19BH 1152 kb/s (1008...
Page 305
NECA 340-414-220 Revision 2.0 Page 3 of 4 MCU 5000A Multipoint Control Unit SPR-026 PICTURE SWITCHING TIMERS 1 TO 4 SETTING PICTURE RELATED STEP PROCEDURE [2] Picture Switch Timer 1 ~ 4 (= 180H ~ 1A7H: Byte) TRANSFER RATETIMER 1 TIMER 2 TIMER 3 TIMER 4 ADDRESSSET UP VALUEADDRESSSET UP VALUEADDRESSSET UP VALUEADDRESSSET UP VALUE 64 kbps x 2 56 kbps x 2+180H 400ms (28H)+181H 1.25s (7DH)+182H 2.4s (18H)+183H 10s (64H) 128 kbps 112 kbps+184H 400ms (28H)+185H 1.25s (7DH)+186H 2.4s (18H)+187H 10s (64H)...
Page 306
Page 4 of 4 NECA 340-414-220 Revision 2.0 SPR-026 MCU 5000A Multipoint Control Unit PICTURE SWITCHING TIMERS 1 TO 4 SETTING PICTURE RELATED STEP PROCEDURE The standard timer values corresponding to communication rates. LINE BIT RATETIME (PARAMETER VALUE) TIMER 1 TIMER 2 TIMER 3 TIMER 4 64 kb/s×2 400 ms (28H) 1.25 s (7DH) 2.4 s (18H) 10 s (64H) 128 kb/s 400 ms (28H) 1.25 s (7DH) 2.4 s (18H) 10 s (64H) 192 kb/s 400 ms (28H) 630 ms (3FH) 1.8 s (12H) 10 s (64H) 256 kb/s 400 ms (28H) 420 ms (2AH) 1.8 s (12H)...
Page 307
NECA 340-414-220 Revision 2.0 Page 1 of 2 MCU 5000A Multipoint Control Unit SPR-027 AUDIO CAPABILITY SETTING TERMINAL CAPABILITY RELATED SUMMARY: Set the audio capability supported by MCU 5000A. MCU 5000A corresponds to “G.725 type 0” (but, without A-Law) STEP PROCEDURE Note: Set the audio capability with the factory shipment value (0AH 00H 00H 00H) as a general rule. If change is necessary for any reason, follow the steps described below. 1 Enter the following command. SSPR__ n1 = x1 __n2 = x2 __...
Page 308
Page 2 of 2 NECA 340-414-220 Revision 2.0 SPR-027 MCU 5000A Multipoint Control Unit AUDIO CAPABILITY SETTING TERMINAL CAPABILITY RELATED STEP PROCEDURE x i: System parameter values See below: [1] System parameter values on setting the audio capability for the addresses 100H to 103H. The factory shipment value for the system parameter is 0AH 00H 00H 00H . SYSTEM PARAMETER AUDIO CAPABILITY ADDRESS 103HADDRESS 102HADDRESS 101HADDRESS 100Hm-law (G.725 TYPE 0) G.722-64 G.722-48 00H 00H 00H 00H OFF OFF...
Page 309
NECA 340-414-220 Revision 2.0 Page 1 of 6 MCU 5000A Multipoint Control Unit SPR-028 TRANSFER RATE CAPABILITY SETTING TERMINAL CAPABILITY RELATED SUMMARY:Set the transfer rates to be used. STEP PROCEDURE Note: When operating at the several transfer rates, set the several transfer rate capabilities to ON. The transfer rates usable, however, may not go beyond the line rates set for the addresses between 30H and 37H. 1 Enter the following command. SSPR__ n1 = x1 __n2 = x2 __ … ni = xi … ¿ ni: System...
Page 310
Page 2 of 6 NECA 340-414-220 Revision 2.0 SPR-028 MCU 5000A Multipoint Control Unit TRANSFER RATE CAPABILITY SETTING TERMINAL CAPABILITY RELATED STEP PROCEDURE x i:System parameter values See below: [2] System parameter values on setting the transfer rate capability for the address 104H. The factory shipment value for the system parameter is C2H. SYSTEM PARAMETER USABLE TRANSFER RATE 00H None 01H 64 kb/s 02H 64 kb/s×2 03H 64 kb/s and 64 kb/s×2 40H 128 kb/s 41H 64 kb/s and 128 kb/s 42H 64 kb/s×2 and...