NECA 340-414-220 Revision 2.0 Page 15 of 18 MCU 5000A Multipoint Control Unit SPR-016 H0-INF LIF CLOCK SOURCE SETTING LINE RELATED SYSTEM PARAMETERLINE NUMBER TO BE MASKEDSYSTEM PARAMETERLINE NUMBER TO BE MASKED 187FH Lines 1,2,3,4,5,6,7,12&13 are masked 81FFH Lines 1,2,3,4,5,6,7,8,9&16 are masked 287FH Lines 1,2,3,4,5,6,7,12&14 are masked 06FFH Lines 1,2,3,4,5,6,7,8,10&11 are masked 487FH Lines 1,2,3,4,5,6,7,12&15 are masked 0CFFH Lines 1,2,3,4,5,6,7,8,10&12 are masked 887FH Lines 1,2,3,4,5,6,7,12&16...
Page 282
Page 16 of 18 NECA 340-414-220 Revision 2.0 SPR-016 MCU 5000A Multipoint Control Unit H0-INF LIF CLOCK SOURCE SETTING LINE RELATED SYSTEM PARAMETERLINE NUMBER TO BE MASKEDSYSTEM PARAMETERLINE NUMBER TO BE MASKED 30FFH Lines 1,2,3,4,5,6,7,8,13&14 are masked 85FFH Lines 1,2,3,4,5,6,7,8,9,11&16 are masked 50FFH Lines 1,2,3,4,5,6,7,8,13&15 are masked 19FFH Lines 1,2,3,4,5,6,7,8,9,12&13 are masked 90FFH Lines 1,2,3,4,5,6,7,8,13&16 are masked 29FFH Lines 1,2,3,4,5,6,7,8,9,12&14 are masked 60FFH Lines...
Page 283
NECA 340-414-220 Revision 2.0 Page 17 of 18 MCU 5000A Multipoint Control Unit SPR-016 H0-INF LIF CLOCK SOURCE SETTING LINE RELATED SYSTEM PARAMETERLINE NUMBER TO BE MASKEDSYSTEM PARAMETERLINE NUMBER TO BE MASKED 1BFFH Lines 1,2,3,4,5,6,7,8,9,10,12&13 are masked57FFH Lines 1,2,3,4,5,6,7,8,9,10,11,13&15 are masked 2BFFH Lines 1,2,3,4,5,6,7,8,9,10,12&14 are masked97FFH Lines 1,2,3,4,5,6,7,8,9,10,11,13&16 are masked 4BFFH Lines 1,2,3,4,5,6,7,8,9,10,12&15 are masked67FFH Lines...
Page 284
Page 18 of 18 NECA 340-414-220 Revision 2.0 SPR-016 MCU 5000A Multipoint Control Unit This page is for your notes.
Page 285
NECA 340-414-220 Revision 2.0 Page 1 of 2 MCU 5000A Multipoint Control Unit SPR-017 TALKER DETECTION BACKWARD PROTECTION TIME SETTING VOICE RELATED SUMMARY: When automatically switching on detection of voice, protection time is set until the start of switching, after detection of voice, by recognizing that conference room in which the voice was detected. STEP PROCEDURE Note: Set talker detection backward protection time with the factory shipment value (0BH ) as a general rule. If change is...
Page 286
Page 2 of 2 NECA 340-414-220 Revision 2.0 SPR-017 MCU 5000A Multipoint Control Unit TALKER DETECTION BACKWARD PROTECTION TIME SETTING VOICE RELATED STEP PROCEDURE SYSTEM PARAMETERTALKER DETECTION BACKWARD PROTECTION TIMESYSTEM PARAMETERTALKER DETECTION BACKWARD PROTECTION TIME 00H 310 ms 08H 230 ms 01H 300 ms 09H 220 ms 02H 290 ms 0AH 210 ms 03H 280 ms 0BH 200 ms 04H 270 ms 0CH 190 ms 05H 260 ms 0DH 180 ms 06H 250 ms 0EH 170 ms 07H 240 ms 0FH 160 ms 10H 150 ms 18H 70 ms 11H 140 ms 19H 60 ms 12H 130...
Page 287
NECA 340-414-220 Revision 2.0 Page 1 of 2 MCU 5000A Multipoint Control Unit SPR-018 TALKER DETECTION FORWARD PROTECTION TIME SETTING VOICE RELATED SUMMARY: When automatically switching on detection of voice, protection time is set until the start of detecting the voice of another talker after disappearance of the current voice signal. STEP PROCEDURE Note: Set talker detection forward protection time with the factory shipment value (0DH ) as a general rule. If change is necessary for any reason, be...
Page 288
Page 2 of 2 NECA 340-414-220 Revision 2.0 SPR-018 MCU 5000A Multipoint Control Unit TALKER DETECTION FORWARD PROTECTION TIME SETTING VOICE RELATED STEP PROCEDURE SYSTEM PARAMETER TALKER DETECTION FORWARD PROTECTION TIMESYSTEM PARAMETER TALKER DETECTION FORWARD PROTECTION TIME 16H 410 ms 2BH 200 ms 17H 400 ms 2CH 190 ms 18H 390 ms 2DH 180 ms 19H 380 ms 2EH 170 ms 1AH 370 ms 2FH 160 ms 1BH 360 ms 30H 150 ms 1CH 350 ms 31H 140 ms 1DH 340 ms 32H 130 ms 1EH 330 ms 33H 120 ms 1FH 320 ms 34H 110 ms 20H 310...
Page 289
NECA 340-414-220 Revision 2.0 Page 1 of 2 MCU 5000A Multipoint Control Unit SPR-019 TALKER DETECTION VOICE LEVEL SETTING VOICE RELATED SUMMARY: Set the threshold level for voice prominence decision when automatically switching on detection of voice. STEP PROCEDURE Note: Use as a general rule the factory shipment value (06H ) for the talker detection voice level. Adjust the detection level higher if required (if the conference room is noisy, etc.). The parameter can be set for every connecting...
Page 290
Page 2 of 2 NECA 340-414-220 Revision 2.0 SPR-019 MCU 5000A Multipoint Control Unit TALKER DETECTION VOICE LEVEL SETTING VOICE RELATED STEP PROCEDURE x i: System parameter values See below: [2] System parameter values to be used when setting talker detection levels for the addresses 60H to 67H. The factory shipment value of the system parameter for setting talker detection level is 06H . SYSTEM PARAMETER TALKER DETECTION VOICE LEVELSYSTEM PARAMETER TALKER DETECTION VOICE LEVEL 00H No talker...