NECA 340-414-220 Revision 2.0 Page 15 of 18
MCU 5000A Multipoint Control Unit SPR-016
H0-INF LIF CLOCK SOURCE SETTING
LINE RELATED
SYSTEM 
PARAMETERLINE NUMBER TO BE MASKEDSYSTEM 
PARAMETERLINE NUMBER TO BE MASKED
187FH Lines 1,2,3,4,5,6,7,12&13 are masked 81FFH Lines 1,2,3,4,5,6,7,8,9&16 are masked
287FH Lines 1,2,3,4,5,6,7,12&14 are masked 06FFH Lines 1,2,3,4,5,6,7,8,10&11 are masked
487FH Lines 1,2,3,4,5,6,7,12&15 are masked 0CFFH Lines 1,2,3,4,5,6,7,8,10&12 are masked
887FH Lines 1,2,3,4,5,6,7,12&16...

Page 282

Page 16 of 18 NECA 340-414-220 Revision 2.0
SPR-016 MCU 5000A Multipoint Control Unit
H0-INF LIF CLOCK SOURCE SETTING
LINE RELATED
SYSTEM 
PARAMETERLINE NUMBER TO BE MASKEDSYSTEM 
PARAMETERLINE NUMBER TO BE MASKED
30FFH Lines 1,2,3,4,5,6,7,8,13&14 are masked 85FFH Lines 1,2,3,4,5,6,7,8,9,11&16 are masked
50FFH Lines 1,2,3,4,5,6,7,8,13&15 are masked 19FFH Lines 1,2,3,4,5,6,7,8,9,12&13 are masked
90FFH Lines 1,2,3,4,5,6,7,8,13&16 are masked 29FFH Lines 1,2,3,4,5,6,7,8,9,12&14 are masked
60FFH Lines...

Page 283

NECA 340-414-220 Revision 2.0 Page 17 of 18
MCU 5000A Multipoint Control Unit SPR-016
H0-INF LIF CLOCK SOURCE SETTING
LINE RELATED
SYSTEM 
PARAMETERLINE NUMBER TO BE MASKEDSYSTEM 
PARAMETERLINE NUMBER TO BE MASKED
1BFFH
Lines 1,2,3,4,5,6,7,8,9,10,12&13 are masked57FFH Lines 1,2,3,4,5,6,7,8,9,10,11,13&15 are 
masked
2BFFH
Lines 1,2,3,4,5,6,7,8,9,10,12&14 are masked97FFH Lines 1,2,3,4,5,6,7,8,9,10,11,13&16 are 
masked
4BFFH
Lines 1,2,3,4,5,6,7,8,9,10,12&15 are masked67FFH Lines...

Page 284

Page 18 of 18 NECA 340-414-220 Revision 2.0
SPR-016 MCU 5000A Multipoint Control Unit
This page is for your notes. 

Page 285

NECA 340-414-220 Revision 2.0 Page 1 of 2
MCU 5000A Multipoint Control Unit SPR-017
TALKER DETECTION BACKWARD PROTECTION TIME SETTING
VOICE RELATED
SUMMARY: When automatically switching on detection of voice, protection time is set until 
the start of switching, after detection of voice, by recognizing that conference 
room in which  the voice was detected.
STEP PROCEDURE 
Note:
Set talker detection backward protection time with the factory shipment value (0BH
) as a 
general rule.  If change is...

Page 286

Page 2 of 2 NECA 340-414-220 Revision 2.0
SPR-017 MCU 5000A Multipoint Control Unit
TALKER DETECTION BACKWARD PROTECTION TIME SETTING
VOICE RELATED
STEP PROCEDURE 
SYSTEM PARAMETERTALKER DETECTION 
BACKWARD
 PROTECTION TIMESYSTEM PARAMETERTALKER DETECTION 
BACKWARD
PROTECTION TIME
00H 310 ms 08H 230 ms
01H 300 ms 09H 220 ms
02H 290 ms 0AH 210 ms
03H 280 ms 0BH 200 ms
04H 270 ms 0CH 190 ms
05H 260 ms 0DH 180 ms
06H 250 ms 0EH 170 ms
07H 240 ms 0FH 160 ms
10H 150 ms 18H 70 ms
11H 140 ms 19H 60 ms
12H 130...

Page 287

NECA 340-414-220 Revision 2.0 Page 1 of 2
MCU 5000A Multipoint Control Unit SPR-018
TALKER DETECTION FORWARD PROTECTION TIME SETTING
VOICE RELATED
SUMMARY: When automatically switching on detection of voice, protection time is set until 
the start of detecting the voice of another talker after disappearance of the current 
voice signal.
STEP PROCEDURE 
Note:
Set talker detection forward protection time with the factory shipment value (0DH
) as a 
general rule.  If change is necessary for any reason, be...

Page 288

Page 2 of 2 NECA 340-414-220 Revision 2.0
SPR-018 MCU 5000A Multipoint Control Unit
TALKER DETECTION FORWARD PROTECTION TIME SETTING
VOICE RELATED
STEP PROCEDURE 
SYSTEM PARAMETER TALKER DETECTION 
FORWARD
 PROTECTION TIMESYSTEM PARAMETER TALKER DETECTION 
FORWARD
 PROTECTION TIME
16H 410 ms 2BH 200 ms
17H 400 ms 2CH 190 ms
18H 390 ms 2DH 180 ms
19H 380 ms 2EH 170 ms
1AH 370 ms 2FH 160 ms
1BH 360 ms 30H 150 ms
1CH 350 ms 31H 140 ms
1DH 340 ms 32H 130 ms
1EH 330 ms 33H 120 ms
1FH 320 ms 34H 110 ms
20H 310...

Page 289

NECA 340-414-220 Revision 2.0 Page 1 of 2
MCU 5000A Multipoint Control Unit SPR-019
TALKER DETECTION VOICE LEVEL SETTING
VOICE RELATED
SUMMARY: Set the threshold level for voice prominence decision when automatically 
switching on detection of voice.
STEP PROCEDURE 
Note:
Use as a general rule the factory shipment value (06H
) for the talker detection voice level.  
Adjust the detection level higher if required (if the conference room is noisy, etc.).  The 
parameter can be set for every connecting...

Page 290

Page 2 of 2 NECA 340-414-220 Revision 2.0
SPR-019 MCU 5000A Multipoint Control Unit
TALKER DETECTION VOICE LEVEL SETTING
VOICE RELATED
STEP PROCEDURE 
x
i:
System parameter values See below:
[2] System parameter values to be used when setting talker detection levels for the addresses 
60H to 67H.
The factory shipment value of the system parameter for setting talker detection level is 
06H
.
SYSTEM PARAMETER TALKER DETECTION  
VOICE LEVELSYSTEM PARAMETER TALKER DETECTION  
VOICE LEVEL
00H No talker...