NEC Mcu 5000a Multipoint Control Unit Equipment Manual
Here you can view all the pages of manual NEC Mcu 5000a Multipoint Control Unit Equipment Manual. The NEC manuals for Communications System are available online for free. You can easily download all the documents as PDF.
Page 311
NECA 340-414-220 Revision 2.0 Page 3 of 6 MCU 5000A Multipoint Control Unit SPR-028 TRANSFER RATE CAPABILITY SETTING TERMINAL CAPABILITY RELATED STEP PROCEDURE [3] System parameter values on setting the transfer rate capability for the address 105H. The factory shipment value for the system parameter is C3H . SYSTEM PARAMETER USABLE TRANSFER RATE 00H None 01H 256 kb/s 02H 384kb/s 03H 256 kb/s and 384 kb/s 40H 512 kb/s 41H 256 kb/s and 512 kb/s 42H 384 kb/s and 512 kb/s 43H 256 kb/s, 384 kb/s, and 512...
Page 312
Page 4 of 6 NECA 340-414-220 Revision 2.0 SPR-028 MCU 5000A Multipoint Control Unit TRANSFER RATE CAPABILITY SETTING TERMINAL CAPABILITY RELATED SYSTEM PARAMETER USABLE TRANSFER RATE 04H 384 kb/s x 2 05H 256 kb/s and 384 kb/s x 2 06H 384 kb/s and 384 kb/s x 2 07H 256 kb/s, 384 kb/s and 384 kb/s x 2 44H 512 kb/s and 384 kb/s x 2 45H 256 kb/s, 512 kb/s, and 384 kb/s x 2 46H 384 kb/s, 512 kb/s, and 384 kb/s x 2 47H 256 kb/s, 384 kb/s, 512 kb/s, and 384 kb/s x 2 84H 768 kb/s and 384 kb/s x 2 85H 256 kb/s,...
Page 313
NECA 340-414-220 Revision 2.0 Page 5 of 6 MCU 5000A Multipoint Control Unit SPR-028 TRANSFER RATE CAPABILITY SETTING TERMINAL CAPABILITY RELATED STEP PROCEDURE [4] System parameter values and hexadecimal numbers on setting the transfer rate capability for the address 106H. The factory shipment value for the system parameter is 0FH . SYSTEM PARAMETER USABLE TRANSFER RATE 00H None 01H 1152 kb/s 02H 1472 kb/s 03H 1152 kb/s and 1472 kb/s 04H 1536 kb/s 05H 1152 kb/s and 1536 kb/s 06H 1536 and 1472 kb/s 07H...
Page 314
Page 6 of 6 NECA 340-414-220 Revision 2.0 SPR-028 MCU 5000A Multipoint Control Unit TRANSFER RATE CAPABILITY SETTING TERMINAL CAPABILITY RELATED STEP PROCEDURE Transfer Rate Capability (+104H ~ 107H) b7 b6b5 b4 b3 b2 b1 b0 b0 : 64 kbps (T1/RS422/INF-H0) b1 : 64 x 2 kbps (T1/RS422/INS-H0)Default = C2 +104H11 0 fixed0 fixed 0 fixed0 fixed 1 0 b6 : 128 kbps (T1/RS422) b7 : 192 kbps (T1/RS422) b7 b6b5 b4 b3 b2 b1 b0 b0 : 256 kbps (T1/RS422) b1 :...
Page 315
NECA 340-414-220 Revision 2.0 Page 1 of 2 MCU 5000A Multipoint Control Unit SPR-029 VIDEO CAPABILITY SETTING TERMINAL CAPABILITY RELATED SUMMARY: Set the H.261 defined video capability. STEP PROCEDURE Note: Set the video capability with the factory shipment value (22H 02H ). If change is necessary for any reason, follow the steps described below. 1 Enter the following command. SSPR__ n1 = x1 __n2 = x2 __ … ni = xi … ¿ ni: System parameter address108H and 109H [1] Video capability corresponding to...
Page 316
Page 2 of 2 NECA 340-414-220 Revision 2.0 SPR-029 MCU 5000A Multipoint Control Unit VIDEO CAPABILITY SETTING TERMINAL CAPABILITY RELATED STEP PROCEDURE x i: System parameter values See below: [1] System parameter values on setting the video capability for the addresses 108H and 109H. The factory shipment value for the system parameter is 22H 02H . SYSTEM PARAMETER VIDEO CAPABILITY ADDRESS 109HADDRESS 108H 00H 05H QCIF: 4/29.79 is ON 00H 09H QCIF: 3/29.79 is ON 00H 11H QCIF: 2/29.79 is ON 00H 21H QCIF:...
Page 317
NECA 340-414-220 Revision 2.0 Page 1 of 2 MCU 5000A Multipoint Control Unit SPR-030 LOW SPEED DATA (LSD) CAPABILITY SETTING TERMINAL CAPABILITY RELATED SUMMARY: Set the transmission capability of MCU 5000A for Low Speed Data (LSD). STEP PROCEDURE Note:MCU 5000A does not support LSD. Be sure, therefore, to use all the system parameters in OFF (0000H) . If change is necessary for any reason, follow the steps described below. 1 Enter the following command. SSPR__ n1 = x1 __n2 = x2 __ … ni = xi … ¿...
Page 318
Page 2 of 2 NECA 340-414-220 Revision 2.0 SPR-030 MCU 5000A Multipoint Control Unit This page is for your notes.
Page 319
NECA 340-414-220 Revision 2.0 Page 1 of 2 MCU 5000A Multipoint Control Unit SPR-031 HIGH SPEED DATA (HSD) CAPABILITY SETTING TERMINAL CAPABILITY RELATED SUMMARY: Set the transmission capability of MCU 5000A for the High Speed Data (HSD). STEP PROCEDURE Note: MCU 5000A does not support HSD in MCON mode. Be sure, therefore, to set all the system parameters to OFF (00H 00H) . If change is necessary, follow the steps described below. 1 Enter the following command. SSPR__ n1 = x1 __n2 = x2 __ … ni = xi...
Page 320
Page 2 of 2 NECA 340-414-220 Revision 2.0 SPR-031 MCU 5000A Multipoint Control Unit HIGH SPEED DATA (HSD) CAPABILITY SETTING TERMINAL CAPABILITY RELATED STEP PROCEDURE SYSTEM PARAMETER HSD (HIGH SPEED DATA) CAPABILITY ADDRESS 10FHADDRESS 10EHADDRESS 10DHADDRESS 10CH 00H 00H 00H 00H OFF 2 Verify that the normal response is displayed with “OK ”. If YES , go to Step 3 . If NO , go to Step 1 . 3 End of procedure.