Page 261
NECA 340-414-220 Revision 2.0 Page 17 of 18 MCU 5000A Multipoint Control Unit SPR-014 RS 422 LIF CLOCK SOURCE SETTING LINE RELATED SYSTEM PARAMETERLINE NUMBER TO BE MASKEDSYSTEM PARAMETERLINE NUMBER TO BE MASKED 1BFFH Lines 1,2,3,4,5,6,7,8,9,10,12&13 are masked57FFH Lines 1,2,3,4,5,6,7,8,9,10,11,13&15 are masked 2BFFH Lines 1,2,3,4,5,6,7,8,9,10,12&14 are masked97FFH Lines 1,2,3,4,5,6,7,8,9,10,11,13&16 are masked 4BFFH Lines 1,2,3,4,5,6,7,8,9,10,12&15 are masked67FFH Lines...
Page 262
Page 18 of 18 NECA 340-414-220 Revision 2.0 SPR-014 MCU 5000A Multipoint Control Unit This page is for your notes.
Page 263
NECA 340-414-220 Revision 2.0 Page 1 of 4 MCU 5000A Multipoint Control Unit SPR-015 H0-INF LIF LINE RATE SETTING LINE RELATED SUMMARY:Set a per-channel communication rate for the communication channels for the H0 lines to and from the connecting conference terminals. Also set the number of conference terminals (in terms of ports) to be accommodated. STEP PROCEDURE 1 Enter the following command. SSPR__ n1 = x1 __n2 = x2 __ … ni = xi … ¿ ni: System parameter address30H to 37H [1] Addresses...
Page 264
Page 2 of 4 NECA 340-414-220 Revision 2.0 SPR-015 MCU 5000A Multipoint Control Unit H0-INF LIF LINE RATE SETTING LINE RELATED STEP PROCEDURE x i: System parameter value See below: [1] System parameter values on setting the line rate for each address (30H, 32H, 34H, 36H). The factory shipment value is 05H . SYSTEM PARAMETER LINE RATE 20H 56 kb/s 30H 56 kb/s×2 00H 64 kb/s 10H 64 kb/s×2 25H 336 kb/s 05H 384 kb/s 15H 384 kb/s x 2 35H 336 kb/s x 2 [2] System parameter values on setting the number of ports...
Page 265
NECA 340-414-220 Revision 2.0 Page 3 of 4 MCU 5000A Multipoint Control Unit SPR-015 H0-INF LIF LINE RATE SETTING LINE RELATED Table 1: Number of Ports For System Parameter SYSTEM PARAMETERNUMBER OF PORTSSYSTEM PARAMETERNUMBER OF PORTSSYSTEM PARAMETERNUMBER OF PORTS 01H 1 21H 33 41H 65 02H 2 22H 34 42H 66 03H 3 23H 35 43H 67 04H 4 24H 36 44H 68 05H 5 25H 37 45H 69 06H 6 26H 38 46H 70 07H 7 27H 39 47H 71 08H 8 28H 40 48H 72 09H 9 29H 41 49H 73 0AH 10 2AH 42 4AH 74 0BH 11 2BH 43 4BH 75 0CH 12 2CH 44...
Page 266
Page 4 of 4 NECA 340-414-220 Revision 2.0 SPR-015 MCU 5000A Multipoint Control Unit H0-INF LIF LINE RATE SETTING LINE RELATED STEP PROCEDURE LINE RATENUMBER OF PORT (SYSTEM PARAMETER)LINE RATENUMBER OF PORT (SYSTEM PARAMETER)LINE RATENUMBER OF PORT (SYSTEM PARAMETER) T1 (64 kb/s) 96 (60H) T1 (1152 kb/s) 4 (04H) T1 (448 kb/s) 12 (0CH) T1 (128 kb/s) 48 (30H) T1 (1536 kb/s) 4 (04H) T1 (672 kb/s) 8 (08H) T1 (192 kb/s) 32 (20H) T1 (56 kb/s) 96 (60H) T1 (1008 kb/s) 4 (04H) T1 (256 kb/s) 24 (18H) T1 (112...
Page 267
NECA 340-414-220 Revision 2.0 Page 1 of 18 MCU 5000A Multipoint Control Unit SPR-016 H0-INF LIF CLOCK SOURCE SETTING LINE RELATED SUMMARY: Specifies the line from which to extract the line clock to be used inside the MCU 5000A. When set to “auto”, the line whose line signal is the first to turn normal will be specified as the clock source, but it will be replaced by the lowest- numbered line currently in normal operation once the line acting as the clock source then ceases being normal. When all the...
Page 268
Page 2 of 18 NECA 340-414-220 Revision 2.0 SPR-016 MCU 5000A Multipoint Control Unit H0-INF LIF CLOCK SOURCE SETTING LINE RELATED STEP PROCEDURE SYSTEM PARAMETERCLOCK SOURCE (CH)SYSTEM PARAMETERCLOCK SOURCE (CH) 00H Automatic (automatic selection of line in its numerical order)09H 9 01H 1 0AH 10 02H 2 0BH 11 03H 3 0CH 12 04H 4 0DH 13 05H 5 0EH 14 06H 6 0FH 15 07H 7 10H 16 08H 8 80H N/A [2] System parameter values on setting the clock source mask for the addresses 3CH and 3DH. The factory shipment...
Page 269
NECA 340-414-220 Revision 2.0 Page 3 of 18 MCU 5000A Multipoint Control Unit SPR-016 H0-INF LIF CLOCK SOURCE SETTING LINE RELATED Note: Marking a line as masked omits it from automatic selection if 3B = 00 SYSTEM PARAMETERLINE NUMBER TO BE MASKEDSYSTEM PARAMETERLINE NUMBER TO BE MASKED 0000H No lines masked 0201H Lines 1&10 are masked 0001H Line 1 is masked 0401H Lines 1&11 are masked 0002H Line 2 is masked 0801H Lines 1&12 are masked 0004H Line 3 is masked 1001H Lines 1&13 are masked 0008H Line 4 is...
Page 270
Page 4 of 18 NECA 340-414-220 Revision 2.0 SPR-016 MCU 5000A Multipoint Control Unit H0-INF LIF CLOCK SOURCE SETTING LINE RELATED SYSTEM PARAMETERLINE NUMBER TO BE MASKEDSYSTEM PARAMETERLINE NUMBER TO BE MASKED 0084H Lines 3&8 are masked 0210H Lines 5&10 are masked 0104H Lines 3&9 are masked 0410H Lines 5&11 are masked 0204H Lines 3&10 are masked 0810H Lines 5&12 are masked 0404H Lines 3&11 are masked 1010H Lines 5&13 are masked 0804H Lines 3&12 are masked 2010H Lines 5&14 are masked 1004H Lines 3&13...