Home > NEC > Communications System > NEC Mcu 5000a Multipoint Control Unit Equipment Manual

NEC Mcu 5000a Multipoint Control Unit Equipment Manual

Here you can view all the pages of manual NEC Mcu 5000a Multipoint Control Unit Equipment Manual. The NEC manuals for Communications System are available online for free. You can easily download all the documents as PDF.

Page 251

NECA 340-414-220 Revision 2.0 Page 7 of 18
MCU 5000A Multipoint Control Unit SPR-014
RS 422 LIF CLOCK SOURCE SETTING
LINE RELATED
SYSTEM 
PARAMETERLINE NUMBER TO BE MASKEDSYSTEM 
PARAMETERLINE NUMBER TO BE MASKED
0441H Lines 1,7&11 are masked 4201H Lines 1,10&15 are masked
0841H Lines 1,7&12 are masked 8201H Lines 1,10&16 are masked
1041H Lines 1,7&13 are masked 0C01H Lines 1,11&12 are masked
2041H Lines 1,7&14 are masked 1401H Lines 1,11&13 are masked
4041H Lines 1,7&15 are masked 2401H Lines 1,11&14...

Page 252

Page 8 of 18 NECA 340-414-220 Revision 2.0
SPR-014 MCU 5000A Multipoint Control Unit
RS 422 LIF CLOCK SOURCE SETTING
LINE RELATED
SYSTEM 
PARAMETERLINE NUMBER TO BE MASKEDSYSTEM 
PARAMETERLINE NUMBER TO BE MASKED
0807H Lines 1,2,3&12 are masked 2013H Lines 1,2,5&14 are masked
1007H Lines 1,2,3&13 are masked 4013H Lines 1,2,5&15 are masked
2007H Lines 1,2,3&14 are masked 8013H Lines 1,2,5&16 are masked
4007H Lines 1,2,3&15 are masked 0063H Lines 1,2,6&7 are masked
8007H Lines 1,2,3&16 are masked 00A3H...

Page 253

NECA 340-414-220 Revision 2.0 Page 9 of 18
MCU 5000A Multipoint Control Unit SPR-014
RS 422 LIF CLOCK SOURCE SETTING
LINE RELATED
SYSTEM 
PARAMETERLINE NUMBER TO BE MASKEDSYSTEM 
PARAMETERLINE NUMBER TO BE MASKED
0503H Lines 1,2,9&11 are masked A003H Lines 1,2,14&16 are masked
0903H Lines 1,2,9&12 are masked C003H Lines 1,2,15&16 are masked
1103H Lines 1,2,9&13 are masked 001FH Lines 1,2,3,4&5 are masked
2103H Lines 1,2,9&14 are masked 002FH Lines 1,2,3,4&6 are masked
4103H Lines 1,2,9&15 are masked...

Page 254

Page 10 of 18 NECA 340-414-220 Revision 2.0
SPR-014 MCU 5000A Multipoint Control Unit
RS 422 LIF CLOCK SOURCE SETTING
LINE RELATED
SYSTEM 
PARAMETERLINE NUMBER TO BE MASKEDSYSTEM 
PARAMETERLINE NUMBER TO BE MASKED
0067H Lines 1,2,3,6&7 are masked 4087H Lines 1,2,3,8&15 are masked
00A7H Lines 1,2,3,6&8 are masked 8087H Lines 1,2,3,8&16 are masked
0127H Lines 1,2,3,6&9 are masked 0307H Lines 1,2,3,9&10 are masked
0227H Lines 1,2,3,6&10 are masked 0507H Lines 1,2,3,9&11 are masked
0427H Lines 1,2,3,6&11 are...

Page 255

NECA 340-414-220 Revision 2.0 Page 11 of 18
MCU 5000A Multipoint Control Unit SPR-014
RS 422 LIF CLOCK SOURCE SETTING
LINE RELATED
SYSTEM 
PARAMETERLINE NUMBER TO BE MASKEDSYSTEM 
PARAMETERLINE NUMBER TO BE MASKED
5007H Lines 1,2,3,13&15 are masked 802FH Lines 1,2,3,4,6&16 are masked
9007H Lines 1,2,3,13&16 are masked 00CFH Lines 1,2,3,4,7&8 are masked
6007H Lines 1,2,3,14&15 are masked 014FH Lines 1,2,3,4,7&9 are masked
A007H Lines 1,2,3,14&16 are masked 024FH Lines 1,2,3,4,7&10 are masked
C007H Lines...

Page 256

Page 12 of 18 NECA 340-414-220 Revision 2.0
SPR-014 MCU 5000A Multipoint Control Unit
RS 422 LIF CLOCK SOURCE SETTING
LINE RELATED
SYSTEM 
PARAMETERLINE NUMBER TO BE MASKEDSYSTEM 
PARAMETERLINE NUMBER TO BE MASKED
060FH Lines 1,2,3,4,10&11 are masked 043FH Lines 1,2,3,4,5,6&11 are masked
0A0FH Lines 1,2,3,4,10&12 are masked 083FH Lines 1,2,3,4,5,6&12 are masked
120FH Lines 1,2,3,4,10&13 are masked 103FH Lines 1,2,3,4,5,6&13 are masked
220FH Lines 1,2,3,4,10&14 are masked 203FH Lines 1,2,3,4,5,6&14 are...

Page 257

NECA 340-414-220 Revision 2.0 Page 13 of 18
MCU 5000A Multipoint Control Unit SPR-014
RS 422 LIF CLOCK SOURCE SETTING
LINE RELATED
SYSTEM 
PARAMETERLINE NUMBER TO BE MASKEDSYSTEM 
PARAMETERLINE NUMBER TO BE MASKED
091FH Lines 1,2,3,4,5,9&12 are masked C01FH Lines 1,2,3,4,5,15&16 are masked
111FH Lines 1,2,3,4,5,9&13 are masked 00FFH Lines 1,2,3,4,5,6,7&8 are masked
211FH Lines 1,2,3,4,5,9&14 are masked 017FH Lines 1,2,3,4,5,6,7&9 are masked
411FH Lines 1,2,3,4,5,9&15 are masked 027FH Lines...

Page 258

Page 14 of 18 NECA 340-414-220 Revision 2.0
SPR-014 MCU 5000A Multipoint Control Unit
RS 422 LIF CLOCK SOURCE SETTING
LINE RELATED
SYSTEM 
PARAMETERLINE NUMBER TO BE MASKEDSYSTEM 
PARAMETERLINE NUMBER TO BE MASKED
063FH Lines 1,2,3,4,5,6,10&11 are masked 10FFH Lines 1,2,3,4,5,6,7,8&13 are masked
0A3FH Lines 1,2,3,4,5,6,10&12 are masked 20FFH Lines 1,2,3,4,5,6,7,8&14 are masked
123FH Lines 1,2,3,4,5,6,10&13 are masked 40FFH Lines 1,2,3,4,5,6,7,8&15 are masked
223FH Lines 1,2,3,4,5,6,10&14 are masked 80FFH...

Page 259

NECA 340-414-220 Revision 2.0 Page 15 of 18
MCU 5000A Multipoint Control Unit SPR-014
RS 422 LIF CLOCK SOURCE SETTING
LINE RELATED
SYSTEM 
PARAMETERLINE NUMBER TO BE MASKEDSYSTEM 
PARAMETERLINE NUMBER TO BE MASKED
187FH Lines 1,2,3,4,5,6,7,12&13 are masked 81FFH Lines 1,2,3,4,5,6,7,8,9&16 are masked
287FH Lines 1,2,3,4,5,6,7,12&14 are masked 06FFH Lines 1,2,3,4,5,6,7,8,10&11 are masked
487FH Lines 1,2,3,4,5,6,7,12&15 are masked 0CFFH Lines 1,2,3,4,5,6,7,8,10&12 are masked
887FH Lines 1,2,3,4,5,6,7,12&16...

Page 260

Page 16 of 18 NECA 340-414-220 Revision 2.0
SPR-014 MCU 5000A Multipoint Control Unit
RS 422 LIF CLOCK SOURCE SETTING
LINE RELATED
SYSTEM 
PARAMETERLINE NUMBER TO BE MASKEDSYSTEM 
PARAMETERLINE NUMBER TO BE MASKED
30FFH Lines 1,2,3,4,5,6,7,8,13&14 are masked 85FFH Lines 1,2,3,4,5,6,7,8,9,11&16 are masked
50FFH Lines 1,2,3,4,5,6,7,8,13&15 are masked 19FFH Lines 1,2,3,4,5,6,7,8,9,12&13 are masked
90FFH Lines 1,2,3,4,5,6,7,8,13&16 are masked 29FFH Lines 1,2,3,4,5,6,7,8,9,12&14 are masked
60FFH Lines...
Start reading NEC Mcu 5000a Multipoint Control Unit Equipment Manual

Related Manuals for NEC Mcu 5000a Multipoint Control Unit Equipment Manual

All NEC manuals