Page 201
NECA 340-414-220 Revision 2.0 Page 1 of 2 MCU 5000A Multipoint Control Unit SPR-003 CONSOLE COMMUNICATION PARAMETER SETTING CONSOLE RELATED SUMMARY:Set a parity of communication parameters for consoles 2 and 3. Note: Communication parameters for MCU console are as follows: Line rate: 9600 b/s, 4800 b/s, 2400 b/s, or 1200 b/s (This is set on DIP switch of PG/SIO unit.) Start bit: 8 bits Stop bit: 1 bit Parity: None or even parity (Even parity can be set in consoles 2 and 3 only.) STEP PROCEDURE 1 Set DIP...
Page 202
Page 2 of 2 NECA 340-414-220 Revision 2.0 SPR-003 MCU 5000A Multipoint Control Unit CONSOLE COMMUNICATION PARAMETER SETTING CONSOLE RELATED STEP PROCEDURE SYSTEM PARAMETERPARITY SYSTEM PARAMETERSYSTEM PARAMETERPARITY CONSOLE 2 CONSOLE 3 CONSOLE 2 CONSOLE 3 00H 0 0 04H 0 1 02H 1 0 06H 1 1 0: No parity (MCU mode) 1: Even parity (VL/TC mode) 3 Verify that the normal response is displayed with “OK ”. If YES , go to Step 4 . If NO , go to Step 2 . 4 End of procedure.
Page 203
NECA 340-414-220 Revision 2.0 Page 1 of 2 MCU 5000A Multipoint Control Unit SPR-004 CONSOLE CODE INDICATION SETTING CONSOLE RELATED SUMMARY:Set an addition of local MCU console code to console response or indication to ON or OFF in console through-pass control. STEP PROCEDURE 1 Enter the following command. SSPR__ n1 = x1 __n2 = x2 __ … __ ni = xi … ¿ ni: System parameter address08H x i: System parameter values See below: System parameter values on setting the code indication. The factory shipment...
Page 204
Page 2 of 2 NECA 340-414-220 Revision 2.0 SPR-004 MCU 5000A Multipoint Control Unit This page is for your notes.
Page 205
NECA 340-414-220 Revision 2.0 Page 1 of 2 MCU 5000A Multipoint Control Unit SPR-005 IDENTIFICATION CODE SETTING CONSOLE RELATED SUMMARY: Set the identification code for each console for console-through-path. Note: In console-through-path, one console can control up to nine consoles. In the same path, two or more same identification codes cannot be set (identification code is different from each other). STEP PROCEDURE 1 Enter the following command. SSPR__ n1 = x1 __n2 = x2 __ … ni = xi … ¿ ni: System...
Page 206
Page 2 of 2 NECA 340-414-220 Revision 2.0 SPR-005 MCU 5000A Multipoint Control Unit This page is for your notes.
Page 207
NECA 340-414-220 Revision 2.0 Page 1 of 2 MCU 5000A Multipoint Control Unit SPR-006 CONSOLE PORT SETTING CONSOLE RELATED SUMMARY: Set a port to normal console use or console-through-pass use. This command also sets whether indication is displayed for each port or not. STEP PROCEDURE 1 Enter the following command. SSPR__ n1 = x1 __n2 = x2 __ … __ ni = xi … ¿ ni: System parameter address0AH x i: System parameter values See below: System parameter values on setting the port type and indication for each...
Page 208
Page 2 of 2 NECA 340-414-220 Revision 2.0 SPR-006 MCU 5000A Multipoint Control Unit CONSOLE PORT SETTING CONSOLE RELATED STEP PROCEDURE [2] Indication SYSTEM PARAMETERINDICATION SYSTEM PARAMETERINDICATION PORT 1 PORT 2 PORT 3 PORT 1 PORT 2 PORT 3 0XH YES YES YES 4XH YES YES NO 1XH NO YES YES 5XH NO YES NO 2XH YES NO YES 6XH YES NO NO 3XH NONO YES 7XH NONONO YES: Indication is displayed according to GRRC command or INET command. NO: Indication is not displayed. X: Any hexadecimal numeral 2 Verify that...
Page 209
NECA 340-414-220 Revision 2.0 Page 1 of 6 MCU 5000A Multipoint Control Unit SPR-007 1.5M LIF LINE RATE SETTING LINE RELATED SUMMARY: Set a per-channel communication rate for the communication channels multiplexed to 1536kbps lines to and from multiple conference terminals. Also set the number of conference terminals (in terms of ports) to be accommodated. STEP PROCEDURE 1 Enter the following command. SSPR__ n1 = x1 __n2 = x2 __ … ni = xi … ¿ ni: System parameter address30H to 37H [1] Address...
Page 210
Page 2 o f 6 NECA 340 -41 4-2 20 Revisi on 2.0 SPR-007 MCU 5000A Mult ipoint Con trol Unit 1.5M LIF LINE R ATE SETTING [2] Sys tem parameter values on set ting the line rate for each address (31H, 33H, 35H, 37H ). The