Page 151
NECA 340-414-210 Revision 2.0 Page 1 of 2 MCU 5000A Multipoint Control Unit GSD-001 1.5M LIF Unit Figure 1: 1.5M LIF Unit NORTESTNOR TEST 1.5 M LIF SW 1 RC1~RC8SW 1 CN 4 CN 3 RC1~RC8 RC 8 6 RC 17 5 4 3INF 4 INF INF INF 3 2 1(AMBER) (AMBER) CN 1 CN 2CN 4 CN 3 (a) SIDE VIEW (b) FRONT VIEW (AMBER) (AMBER) (LED)2 S1 S2 Table 1: Switch and Strap Setting for 1.5M LIF Unit Component Setting Function Shipping Condition S1 TEST sideAccess to CPU irrespective of slot address for mounting position of...
Page 152
Page 2 of 2 NECA 340-414-210 Revision 2.0 GSD-001 MCU 5000A Multipoint Control Unit Table 2: LED Functions for 1.5M LIF Unit COMPONENT INF NO. ALARM FUNCTION Remarks RC1 CH 1 (CH 5) (CH 9) (CH 13)REC NOS (input loss), LOS (out of sync) AIS AIS (network side fault) RC2RAI RAI (remote alarm) NORMAL Other than the above alarms or normal. RC3 CH 2 (CH 6) (CH 10) (CH 14)REC NOS (input loss), LOS (out of sync) AIS AIS (network side fault) RC4RAI RAI (remote alarm) NORMAL Other than the above alarms or...
Page 153
NECA 340-414-210 Revision 2.0 Page 1 of 4 MCU 5000A Multipoint Control Unit GSD-002 RS-422 LIF Unit Figure 1: RS-422 LIF Unit Strap S11 ~ S22 according to Ta b l e 1. S3 1 00 0 1 0 S11 S5 S6 S M S7 0 1 0 S8 1 0 RC1 RC3 RC4 RC5 RC6 RC8 CH 4 (AMBER) CH 3 (AMBER) CH 2 (AMBER) CH 1 (AMBER) (LED)RC7 RC2 CN 4 CN 3 CN 3CN 4 RC8~RC1SW 1 RS-422/HSD IF SW 1 RC1~RC8 CN 1 CN 2 TEST NOR S21 S22HSD LIF S121 0 1M SS9 S1 S2 1 1 0M S 0 T 0 T0 0 T 0T T 0T0 0 T T 0S MS10 S17 S16 S15 S14 S13 S20 S19 S18 (a)...
Page 154
Page 2 of 4 NECA 340-414-210 Revision 2.0 GSD-002 MCU 5000A Multipoint Control Unit * Standard Setting ¬Indicate the connection between MCU and DCE with I/F device. (Straight conversion cable usage.) ÁIndicate the connection between MCU and DTE with I/F device. (Cross conversion cable usage.) ÂIndicate the connection between MCU and X.21 (DCE) with I/F device. (Straight conversion cable usage.) When shipping, Switches and Straps are get ¬ position. Table 1: Strap Setting for RS-422 LIF (1 of 2)...
Page 155
NECA 340-414-210 Revision 2.0 Page 3 of 4 MCU 5000A Multipoint Control Unit GSD-002 * Standard Setting ¬Indicate the connection between MCU and DCE with I/F device. (Straight conversion cable usage.) ÁIndicate the connection between MCU and DTE with I/F device. (Cross conversion cable usage.) ÂIndicate the connection between MCU and X.21 (DCE) with I/F device. (Straight conversion cable usage.) When shipping, Switches and Straps are get ¬ position. Table 1: Strap Setting for RS-422 LIF (2 of 2)...
Page 156
Page 4 of 4 NECA 340-414-210 Revision 2.0 GSD-002 MCU 5000A Multipoint Control Unit Note: ( ) indicates the channel number for LIF2/3/4 unit, respectively. Table 2: Switch Setting for RS-422 LIF COMPONENT SETTING FUNCTION SHIPPING CONDITION SW1 - Set the following loop: 1. CH1 F point Local Loop 2. CH1 F point Remote Loop 3. CH2 F point Local Loop 4. CH2 F point Remote Loop 5. CH3 F point Local Loop 6. CH3 F point Remote Loop 7. CH4 F point Local Loop 8. CH4 F point Remote LoopALL OFF OFF...
Page 157
NECA 340-414-210 Revision 2.0 Page 1 of 4 MCU 5000A Multipoint Control Unit GSD-003 H0-INF Unit Figure 1: H0-INF Unit CN5 PIIFC CH2 DEBUG (RS-232C RxD, TxD GND) CN 4,5 SW 1 LIF CH 2 PHYSICAL STATE (AMBER) CH 2 F/W ALARM (RED) CH 2 LAYER 2 INDICATION (GREEN) CH 2 PHACT (GREEN) CH 1 PHYSICAL STATE (AMBER) CH 1 F/W ALARM (RED) CH 1 LAYER 2 INDICATION (GREEN) CH 2 PHACT (GREEN) PIIFC CH2 PIIFC CH1 GND 4 1 SW 1 RC 12 RC 6 SW 3 SW 2 8 1 4 1 4 1 RC 12 RC 7 RC 6 RC 1 SW 3 SW 2 CN 5 CN 4CN 3 CN 1...
Page 158
Page 2 of 4 NECA 340-414-210 Revision 2.0 GSD-003 MCU 5000A Multipoint Control Unit Table 1: Switch and Strap Setting for H0-INF Unit Component Setting Function Shipping Condition S1 TEST side Access to CPU irrespective of slot address for mounting position of unit.NOR side NOR side Normal condition S2 - Line Switch (CH1) INS side T1 side Private Line (~1.5M) INS side INS NET 1500 S3 - Line Switch (CH2) T1 side Private Line (~1.5M) INS side INS NET 1500 S4 NOR side Normal condition NOR side TEST side...
Page 159
NECA 340-414-210 Revision 2.0 Page 3 of 4 MCU 5000A Multipoint Control Unit GSD-003 Table 2: LED Functions for H0-INF Unit LED NO. STATE FUNCTION LED COLOR RC 1 lV40 F/W alarm for CH1 RED RC 2 lLayer 2 Normal Operation for CH1 GREEN mLayer 2 Not Normal for CH1 RC 3 lLayer 1 Normal Operation for CH1 mLayer 1 Not Normal for CH1 RC 4 RC 5 RC 6RC 4 RC 5 RC 6 Physical state indication for CH1 mmmNormal Operation YELLOW lmmRAI receive llmLoss of signal, Out of frame mlmAIS receive mmlRAI or Continuous CRC...
Page 160
Page 4 of 4 NECA 340-414-210 Revision 2.0 GSD-003 MCU 5000A Multipoint Control Unit This page is for your notes.