Home > NEC > Communications System > NEC Mcu 5000a Multipoint Control Unit Equipment Manual

NEC Mcu 5000a Multipoint Control Unit Equipment Manual

Here you can view all the pages of manual NEC Mcu 5000a Multipoint Control Unit Equipment Manual. The NEC manuals for Communications System are available online for free. You can easily download all the documents as PDF.

Page 111

NECA 340-414-210 Revision 2.0 Page 9 of 14
MCU 5000A Multipoint Control Unit INT-001
D: Equipment 
Handling3.04
The handlings for MCU 5000A are shown as below.  The details are 
described each procedures.
Detailed Procedure
Reference Procedure No
Mount MCU 5000A to 19 inch rack INP-001
Remove MCU 5000A from 19 inch rack INP-002
Open/Remove Front Cover INP-003
Install/Close Front Cover INP-004
Turn ON/OFF power switch INP-005
Mount Unit to shelf INP-006
Remove Unit From shelf INP-007
Internal connection...

Page 112

Page 10 of 14 NECA 340-414-210 Revision 2.0
INT-001 MCU 5000A Multipoint Control Unit
4:  CABLE CONNECTIONS
A: General 4.01The following should be examined for cable installation of MCU 5000A.
• The customer is required to prepare all cables which are connected MCU 
5000A and external terminal devices before starting the installation.
• Decide the proper lengths of the cables while taking into account the 
distance between MCU 5000A and external terminal devices.
• Design cable wiring routes for the MCU...

Page 113

NECA 340-414-210 Revision 2.0 Page 11 of 14
MCU 5000A Multipoint Control Unit INT-001
Figure 4-1:   Cable Wiring Procedure for Connecting MCU 5000A and External Terminal Device
Prepare drawings for cable wiring.  
Draw the following figures if necessary.
• Cable wiring maps
• Cable wiring diagrams
Prepare cable wiring materials.
• Cable arrangements by customer
• Arrangements for connectors for external terminal device
• Checking on MCU 5000A accessories and connectors
Wiring of interface cables between...

Page 114

Page 12 of 14 NECA 340-414-210 Revision 2.0
INT-001 MCU 5000A Multipoint Control Unit
B: Connectors and 
Connections4.04Internal connections:
 This equipment is required internal connections.  
Refer to INP-008
 for details.
4.05External connections:
 All the cables which connect between MCU 5000A 
and other external device are connected on the rear connectors of MCU  
5000A shelf.     Fig. 4-2 shows the typical cable connections, and 
Table 4-1 shows details for cables connectors and connecting...

Page 115

NECA 340-414-210 Revision 2.0 Page 13 of 14
MCU 5000A Multipoint Control Unit INT-001
Table 4-1: EXTERNAL CABLE CONNECTIONS
CABLE NAMECONNECTORS FOR 
EQUIPMENT SIDECONNECTORS FOR 
CABLE SIDEQUANTITY OF 
PINREFERENCE NO.
LIF Cable (CH1 to 16) DA-15S Socket DA-15P Plug 15 INP-009
RS-232C Cable (CH1 to 4) DB-25S SocketDB-25P Plug or 
Equivalent25 Needless for option
AC Power Cord - - 3 INP-011 

Page 116

Page 14 of 14 NECA 340-414-210 Revision 2.0
INT-001 MCU 5000A Multipoint Control Unit
This page is for your notes. 

Page 117

NECA 340-414-210 Revision 2.0 Page 1 of 2
MCU 5000A Multipoint Control Unit INP-001
MOUNT MCU 5000A TO 19-INCH RACK
GENERAL: 
This procedure describes the steps required to mount the MCU 5000A in 19-inch 
rack.
APPARATUS:
Phillips type Screwdriver 
SUPPORT DATA: 
None
STEP PROCEDURE
1 Prepare eight screws which are annexed to equipment.
2 Install MCU 5000A shelf on the appointed location of 19-inch rack as shown in Fig. 1.
3 Tighten the eight screws and fix firmly MCU 5000A to the rack.
4 Are more MCU...

Page 118

Page 2 of 2 NECA 340-414-210 Revision 2.0
INP-001 MCU 5000A Multipoint Control Unit
Figure 1:   Mounting MCU 5000A to 19-inch Rack
MCU 5000A
MCU 5000A 

Page 119

NECA 340-414-210 Revision 2.0 Page 1 of 2
MCU 5000A Multipoint Control Unit INP-002
  REMOVE MCU 5000A FROM 19-INCH RACK
GENERAL: 
This procedure describes the steps required to remove the MCU 5000A from the 
19-inch rack.
APPARATUS: 
Phillips type 
Screwdriver 
SUPPORT DATA: 
INP-005
STEP PROCEDURES
1If power switch is already OFF, go to Step 2.
Otherwise turn OFF power switch.  Refer to 
INP-005.
2 Are the cables connected?
If Ye s
, go to Step 3
.
If No
, go to Step 5
.
3 Record which cables are...

Page 120

Page 2 of 2 NECA 340-414-210 Revision 2.0
INP-002 MCU 5000A Multipoint Control Unit
Figure 1:   How to Remove MCU 5000A out of 19-Inch Rack
MCU 5000A
MCU 5000A 