Page 141

NECA 340-414-210 Revision 2.0 Page 3 of 4
MCU 5000A Multipoint Control Unit INP-009
Figure 3:   LIF (CH1 to CH16) Cable Connections  
8
151
9 

Page 142

Page 4 of 4 NECA 340-414-210 Revision 2.0
INP-009 MCU 5000A Multipoint Control Unit
This page is for your notes. 

Page 143

NECA 340-414-210 Revision 2.0 Page 1 of 2
MCU 5000A Multipoint Control Unit INP-011
POWER CORD CONNECTION
GENERAL: 
This  cord is used to supply power to MCU.  This procedure provides the 
instruction.
APPARATUS: 
None
SUPPORT DATA: 
None
Figure 1:   Power Cord Connection
STEP PROCEDURES
1Set power switch of MCU 5000A to the OFF position.
2 Connect the power cord to the power terminal at rear side of MCU 5000A.  (See Fig. 1 and Ta b l e  1.)
3 End of procedure.
48.4 inches (1.23 meters) 

Page 144

Page 2 of 2 NECA 340-414-210 Revision 2.0
INP-011 MCU 5000A Multipoint Control Unit
Figure 2:   AC IN SIGNAL ASSIGNMENT
Table 1: AC IN Connector Pin Assignment
PIN NO. SIGNAL NAME I/O REMARKS
1 AC IN IN AC 117 V input
2 AC IN IN AC 117 V input
3 FG - Frame ground
12
3 

Page 145

NECA 340-4 14- 21 0  Revisio n 2.0   Page 1 o f 4
MCU  5000A Multipoint Control  U nit   INP-012
  STA RT-UP OF MCU CONSOLE 

Page 146

Page 2 o f 4   NECA 340 -41 4-2 10 Revisi on  2.0
INP-012   MCU 5000A Mult ipoint Con trol Unit
STEP   PROCEDURES 

Page 147

NECA 340-414-210 Revision 2.0 Page 3 of 4
MCU 5000A Multipoint Control Unit INP-012
Figure 1:   Connection of MCU Console to MCU 5000A
Note:    
x.xx indicates version No. of memory card.
Figure 2:   Opening Message
MCU  REAR  TERMINAL  ARRANGEMENT RS-232C
AC  IN
CH1CH5 CH1
CH13
CH9
CH5CH1
CH2CH6 CH2 CH14 CH10
CH6CH2
CH7 CH3 CH3 CH15 CH11 CH7 CH3
CH4 CH8 CH4 CH16 CH12 CH8 CH4
RS-232CHSD  IFL IF
RS-232C MCU CONSOLE
(REVERSE)
PORT
Note:  The channel 4 (CH4) at RS-232C interface port does not support...

Page 148

Page 4 of 4 NECA 340-414-210 Revision 2.0
INP-012 MCU 5000A Multipoint Control Unit
Figure 3:   RS-232C (CH1 to CH4) Connector Pin Assignment
Table 1: RS-232C (CH1 TO CH4) SIGNAL ASSIGNMENT
PIN NO. SIGNAL NAME I/O REMARKS PIN NO. SIGNAL NAME I/O REMARKS
1 FG - Frame Ground 14 -
2 SD OUT
Send Data15
ST2IN Send Signal  
Element Timing
3 RD IN Receive  Data 16 -
4 RS OUT
Request Send17
RTOUT Receive Signal  
Element Timing
5 CS IN Capacity Send 18 -
6 DR IN Data Set Ready 19 -
7SG -
Signal ground20
EROUT...

Page 149

NECA 340-414-210 Revision 2.0 Page 1 of 2
MCU 5000A Multipoint Control Unit INP-013
SETTING FOR CODEC
GENERAL: 
This procedure provides instruction for parameter setting about CODEC 
(VisuaLink 5000) using for TV conference terminal.
APPARATUS: 
None
SUPPORT DATA: 
VL 5000 Manual
STEP PROCEDURE
1 The  functional parameter required for VL 5000 are registered in  the  non-volatile memory.
At system starting, functional parameters which are registered in the  non-volatile  memory  are 
automatically loaded,...

Page 150

Page 2 of 2 NECA 340-414-210 Revision 2.0
INP-013 MCU 5000A Multipoint Control Unit
This page is for your notes. 