NECA 340-414-220 Revision 2.0 Page 3 of 6
MCU 5000A Multipoint Control Unit SPR-007
1.5M LIF LINE RATE SETTING
LINE RELATED
Table 1: Number of Ports for System Parameter
SYSTEM 
PARAMETERNUMBER OF 
PORTSSYSTEM 
PARAMETERNUMBER OF 
PORTSSYSTEM 
PARAMETERNUMBER OF 
PORTS
01H 1 21H 33 41H 65
02H 2 22H 34 42H 66
03H 3 23H 35 43H 67
04H 4 24H 36 44H 68
05H 5 25H 37 45H 69
06H 6 26H 38 46H 70
07H 7 27H 39 47H 71
08H 8 28H 40 48H 72
09H 9 29H 41 49H 73
0AH 10 2AH 42 4AH 74
0BH 11 2BH 43 4BH 75
0CH 12 2CH 44 4CH...

Page 212

Page 4 of 6 NECA 340-414-220 Revision 2.0
SPR-007 MCU 5000A Multipoint Control Unit
1.5M LIF LINE RATE SETTING
LINE RELATED
 
STEP PROCEDURE 
Table 2: Maximum Number of Available Ports for Line Rate
LINE RATENUMBER OF 
PORTS (SYSTEM 
PARAMETER)LINE RATENUMBER OF 
PORTS (SYSTEM 
PARAMETER)LINE RATENUMBER OF 
PORTS (SYSTEM 
PARAMETER)
T1(64kbps) 96 (60H) T1 (1152kbps) 4 (04H) T1 (448kbps) 12 (0CH)
T1 (128kbps) 48 (30H) T1 (1536kbps) 4 (04H) T1 (672kbps) 8 (08H)
T1 (192kbps) 32 (20H) T1 (56kbps) 96 (60H) T1...

Page 213

NECA 340-414-220 Revision 2.0 Page 5 of 6
MCU 5000A Multipoint Control Unit SPR-007
1.5M LIF LINE RATE SETTING
LINE RELATED
SOFEWARE SETUP
The following are addresses that need to be set in the MCU 5000A.  Set the 
following addresses to the appropriate values and RESET the MCU when 
complete.
Note 1:
  If the value other than the ones listed above is set, it will not function.
Note 2:
  # can not specify the internal clock.(1) Line Speed (+30H, +32H, +34H, +36H)
ADDRESSLINE SPEED MINIMUM LINE 
SPEED...

Page 214

Page 6 of 6 NECA 340-414-220 Revision 2.0
SPR-007 MCU 5000A Multipoint Control Unit
1.5M LIF LINE RATE SETTING
LINE RELATED
(2) Number of Logical Line Speed (+31H, +33H, +35H, +37H)
ADDRESSNUMBER OF VALID LOGICAL LINE
T1 RS422 INS-64 DEFAULT
LIF1 +31H 64kbps : 00H ~ 60H (96)
128kbps : 00H ~ 30H (48)
192kbps : 00H ~ 20H (32)
256kbps : 00H ~ 18H (24)
384kbps : 00H ~ 10H (16)
512kbps : 00H ~ 00H (12)
768kbps : 00H ~ 08H (8)
1152kbps : 00H ~ 04H (4)
1472kbps : 00H ~ 04H (4)
1536kbps : 00H ~ 04H (4)00H ~ 04H...

Page 215

NECA 340-414-220 Revision 2.0 Page 1 of 2
MCU 5000A Multipoint Control Unit SPR-008
1.5M LIF FRAME FORMAT SETTING
LINE RELATED
SUMMARY: 
Set the line frame format.
STEP PROCEDURE 
1 Enter the following command.
SSPR__ n1 =  x1 __n2 = x2 __ … ni = xi … ¿
ni:
System parameter address38H
x
i:
System parameter values See below:
[1] System parameter values on setting the frame format for the address 38H
.  The factory 
shipment value for the system parameter is 00H
.
(1) Frame Format (+38H)
b7
b6b5
b4 b3 b2...

Page 216

Page 2 of 2 NECA 340-414-220 Revision 2.0
SPR-008 MCU 5000A Multipoint Control Unit
This page is for your notes. 

Page 217

NECA 340-414-220 Revision 2.0 Page 1 of 2
MCU 5000A Multipoint Control Unit SPR-009
1.5M LIF LINE CODE SETTING
LINE RELATED
SUMMARY:
Set the line code form.  The line code can be set to each unit.  When the code form 
is in AMI as in the North American lines, it is necessary to set the network class to 
the constrained network (P×56 kbps) in order to prevent the appearance in string 
of eight  consecutive 0s (zeroes).
STEP PROCEDURE 
Note:
When setting the AMI code, simultaneously set the network...

Page 218

Page 2 of 2 NECA 340-414-220 Revision 2.0
SPR-009 MCU 5000A Multipoint Control Unit
This page is for your notes. 

Page 219

NECA 340-414-220 Revision 2.0 Page 1 of 2
MCU 5000A Multipoint Control Unit SPR-010
1.5M LIF RAI SETTING
LINE RELATED
SUMMARY:
Set the alarm signal types.  The alarm signal types can be set to each unit.
STEP PROCEDURE 
Note:
When the frame format is “D4 (12MF)”, the RAI  (alarm signal) form in T1 (USA) is different 
from that in NTT (Japan).   Only when connecting to NTT lines with “F12”, set the mode to  
“NTT.”
1Enter the following command.
SSPR__ n1 =  x1 __n2 = x2 __ … ni = xi … ¿
ni:
System...

Page 220

Page 2 of 2 NECA 340-414-220 Revision 2.0
SPR-010 MCU 5000A Multipoint Control Unit