Page 241

NECA 340-414-220 Revision 2.0 Page 1 of 4
MCU 5000A Multipoint Control Unit SPR-013
RS 422 LIF LINE RATE SETTING
LINE RELATED
SUMMARY:
Set the rate of communication to and from the connecting conference terminals.  
The rate can be set independently for each package of RS 422 LIF (LIF 1 to 4).  
However, it must be noted that conference terminals having different rates cannot 
be connected to each other, nor can be permitted to participle in the same 
conference.
STEP PROCEDURE 
Note:
The number of ports...

Page 242

Page 2 of 4 NECA 340-414-220 Revision 2.0
SPR-013 MCU 5000A Multipoint Control Unit
RS 422 LIF LINE RATE SETTING
LINE RELATED
STEP PROCEDURE 
x
i:
System parameter values See  below:
[1] System parameter values on setting the line rate for each address (30H, 32H, 34H, 36H).
The factory shipment value for the system parameter is 05H
.
SYSTEM PARAMETER LINE RATE SYSTEM PARAMETER LINE RATE
20H 56 kb/s 25H 336 kb/s 
30H 56 kb/s × 2 05H 384 kb/s
00H 64 kb/s 04H 512 kb/s
10H 64 kb/s × 2  06H 768 kb/s
21H 112...

Page 243

NECA 340-414-220 Revision 2.0 Page 3 of 4
MCU 5000A Multipoint Control Unit SPR-013
RS 422 LIF LINE RATE SETTING
LINE RELATED
Table 1: Number of Ports for System Parameter
SYSTEM 
PARAMETERNUMBER OF 
PORTSSYSTEM 
PARAMETERNUMBER OF 
PORTSSYSTEM 
PARAMETERNUMBER OF 
PORTS
01H 1 21H 33 41H 65
02H 2 22H 34 42H 66
03H 3 23H 35 43H 67
04H 4 24H 36 44H 68
05H 5 25H 37 45H 69
06H 6 26H 38 46H 70
07H 7 27H 39 47H 71
08H 8 28H 40 48H 72
09H 9 29H 41 49H 73
0AH 10 2AH 42 4AH 74
0BH 11 2BH 43 4BH 75
0CH 12 2CH 44...

Page 244

Page 4 of 4 NECA 340-414-220 Revision 2.0
SPR-013 MCU 5000A Multipoint Control Unit
RS 422 LIF LINE RATE SETTING
LINE RELATED
STEP PROCEDURE 
Table 2: Maximum Number of Available Ports for Line Rate
LINE RATE NUMBER OF 
PORT (SYSTEM 
PARAMETER)LINE RATE NUMBER OF 
PORT (SYSTEM 
PARAMETER)LINE RATE NUMBER OF 
PORT (SYSTEM 
PARAMETER)
T1 (64 kb/s) 96 (60H) T1 (1152 kb/s) 4 (04H) T1 (448 kb/s) 12 (0CH)
T1 (128 kb/s) 48 (30H) T1 (1536 kb/s) 4 (04H) T1 (672 kb/s) 8 (08H)
T1 (192 kb/s) 32 (20H) T1 (56 kb/s) 96...

Page 245

NECA 340-414-220 Revision 2.0 Page 1 of 18
MCU 5000A Multipoint Control Unit SPR-014
RS 422 LIF CLOCK SOURCE SETTING
LINE RELATED
SUMMARY:
Specify the line from which to extract the line clock to be used inside the MCU 
5000A.  When set to “auto”, the line whose line signal is the first to turn normal 
will be specified as the clock source, but it will be replaced by the lowest-
numbered line currently in normal operation once the line acting as the clock 
source then ceases being normal.  When all the...

Page 246

Page 2 of 18 NECA 340-414-220 Revision 2.0
SPR-014 MCU 5000A Multipoint Control Unit
RS 422 LIF CLOCK SOURCE SETTING
LINE RELATED
STEP PROCEDURE 
x
i:
System parameter values See below:
[1]
System parameter values on setting the clock source for the address 3BH.
The factory shipment value for the system parameter is 00H
.
SYSTEM PARAMETER LINE NUMBER SYSTEM PARAMETER LINE NUMBER
00HAutomatic (Automatic 
selection of line in its 
numerical order)09H 9
01H 1 0AH 10
02H 2 0BH 11
03H 3 0CH 12
04H 4 0DH 13...

Page 247

NECA 340-414-220 Revision 2.0 Page 3 of 18
MCU 5000A Multipoint Control Unit SPR-014
RS 422 LIF CLOCK SOURCE SETTING
LINE RELATED
Note:  
Marking a line as masked omits it from automatic selection if 3B = 00.
SYSTEM 
PARAMETERLINE NUMBER TO BE MASKEDSYSTEM 
PARAMETERLINE NUMBER TO BE MASKED
0000H No lines masked 0201H Lines 1&10 are masked
0001H Line 1 is masked 0401H Lines 1&11 are masked
0002H Line 2 is masked 0801H Lines 1&12 are masked
0004H Line 3 is masked 1001H Lines 1&13 are masked
0008H Line 4...

Page 248

Page 4 of 18 NECA 340-414-220 Revision 2.0
SPR-014 MCU 5000A Multipoint Control Unit
RS 422 LIF CLOCK SOURCE SETTING
LINE RELATED
SYSTEM 
PARAMETERLINE NUMBER TO BE MASKEDSYSTEM 
PARAMETERLINE NUMBER TO BE MASKED
0084H Lines 3&8 are masked 0210H Lines 5&10 are masked
0104H Lines 3&9 are masked 0410H Lines 5&11 are masked
0204H Lines 3&10 are masked 0810H Lines 5&12 are masked
0404H Lines 3&11 are masked 1010H Lines 5&13 are masked
0804H Lines 3&12 are masked 2010H Lines 5&14 are masked
1004H Lines 3&13...

Page 249

NECA 340-414-220 Revision 2.0 Page 5 of 18
MCU 5000A Multipoint Control Unit SPR-014
RS 422 LIF CLOCK SOURCE SETTING
LINE RELATED
SYSTEM 
PARAMETERLINE NUMBER TO BE MASKEDSYSTEM 
PARAMETERLINE NUMBER TO BE MASKED
8040H Lines 7&16 are masked 4400H Lines 11&15 are masked
0180H Lines 8&9 are masked 8400H Lines 11&16 are masked
1280H Lines 8&10 are masked 1800H Lines 12&13 are masked
0480H Lines 8&11 are masked 2800H Lines 12&14 are masked
0880H Lines 8&12 are masked 4800H Lines 12&15 are masked
1080H Lines...

Page 250

Page 6 of 18 NECA 340-414-220 Revision 2.0
SPR-014 MCU 5000A Multipoint Control Unit
RS 422 LIF CLOCK SOURCE SETTING
LINE RELATED
SYSTEM 
PARAMETERLINE NUMBER TO BE MASKEDSYSTEM 
PARAMETERLINE NUMBER TO BE MASKED
8003H Lines 1,2&16 are masked 8009H Lines 1,4&16 are masked
00D0H Lines 1,3&4 are masked 0031H Lines 1,5&6 are masked
0015H Lines 1,3&5 are masked 0051H Lines 1,5&7 are masked
0025H Lines 1,3&6 are masked 0091H Lines 1,5&8 are masked
0045H Lines 1,3&7 are masked 0111H Lines 1,5&9 are masked...