Page 221
NECA 340-414-220 Revision 2.0 Page 1 of 18 MCU 5000A Multipoint Control Unit SPR-011 1.5M LIF CLOCK SOURCE SETTING LINE RELATED SUMMARY: Specifies the line from which to extract the line clock to be used inside the MCU 5000A. When set to “auto”, the line whose line signal is the first to turn normal will be specified as the clock source, but it will be replaced by the lowest- numbered line currently in normal operation once the line acting as the clock source then ceases being normal. When all the...
Page 222
Page 2 of 18 NECA 340-414-220 Revision 2.0 SPR-011 MCU 5000A Multipoint Control Unit 1.5M LIF CLOCK SOURCE SETTING LINE RELATED STEP PROCEDURE SYSTEM PARAMETER CLOCK SOURCE (CH) SYSTEM PARAMETER CLOCK SOURCE (CH) 00H Automatic (automatic selection of line in its numerical order)09H 9 01H 1 0AH 10 02H 2 0BH 11 03H 3 0CH 12 04H 4 0DH 13 05H 5 0EH 14 06H 6 0FH 15 07H 7 10H 16 08H 8 80H Internal [2] System parameter values on setting the clock source mask for the addresses 3CH and 3DH. The factory...
Page 223
NECA 340-414-220 Revision 2.0 Page 3 of 18 MCU 5000A Multipoint Control Unit SPR-011 1.5M LIF CLOCK SOURCE SETTING LINE RELATED Note: Marking a line as masked omits it from automatic selection if 3B = 00 SYSTEM PARAMETERLINE NUMBER TO BE MASKEDSYSTEM PARAMETERLINE NUMBER TO BE MASKED 0000H No lines masked 0201H Lines 1&10 are masked 0001H Line 1 is masked 0401H Lines 1&11 are masked 0002H Line 2 is masked 0801H Lines 1&12 are masked 0004H Line 3 is masked 1001H Lines 1&13 are masked 0008H Line 4 is...
Page 224
Page 4 of 18 NECA 340-414-220 Revision 2.0 SPR-011 MCU 5000A Multipoint Control Unit 1.5M LIF CLOCK SOURCE SETTING LINE RELATED SYSTEM PARAMETERLINE NUMBER TO BE MASKEDSYSTEM PARAMETERLINE NUMBER TO BE MASKED 0084H Lines 3&8 are masked 0210H Lines 5&10 are masked 0104H Lines 3&9 are masked 0410H Lines 5&11 are masked 0204H Lines 3&10 are masked 0810H Lines 5&12 are masked 0404H Lines 3&11 are masked 1010H Lines 5&13 are masked 0804H Lines 3&12 are masked 2010H Lines 5&14 are masked 1004H Lines 3&13 are...
Page 225
NECA 340-414-220 Revision 2.0 Page 5 of 18 MCU 5000A Multipoint Control Unit SPR-011 1.5M LIF CLOCK SOURCE SETTING LINE RELATED SYSTEM PARAMETERLINE NUMBER TO BE MASKEDSYSTEM PARAMETERLINE NUMBER TO BE MASKED 8040H Lines 7&16 are masked 4400H Lines 11&15 are masked 0180H Lines 8&9 are masked 8400H Lines 11&16 are masked 1280H Lines 8&10 are masked 1800H Lines 12&13 are masked 0480H Lines 8&11 are masked 2800H Lines 12&14 are masked 0880H Lines 8&12 are masked 4800H Lines 12&15 are masked 1080H Lines...
Page 226
Page 6 of 18 NECA 340-414-220 Revision 2.0 SPR-011 MCU 5000A Multipoint Control Unit 1.5M LIF CLOCK SOURCE SETTING LINE RELATED SYSTEM PARAMETERLINE NUMBER TO BE MASKEDSYSTEM PARAMETERLINE NUMBER TO BE MASKED 8003H Lines 1,2&16 are masked 8009H Lines 1,4&16 are masked 00D0H Lines 1,3&4 are masked 0031H Lines 1,5&6 are masked 0015H Lines 1,3&5 are masked 0051H Lines 1,5&7 are masked 0025H Lines 1,3&6 are masked 0091H Lines 1,5&8 are masked 0045H Lines 1,3&7 are masked 0111H Lines 1,5&9 are masked 0085H...
Page 227
NECA 340-414-220 Revision 2.0 Page 7 of 18 MCU 5000A Multipoint Control Unit SPR-011 1.5M LIF CLOCK SOURCE SETTING LINE RELATED SYSTEM PARAMETERLINE NUMBER TO BE MASKEDSYSTEM PARAMETERLINE NUMBER TO BE MASKED 0441H Lines 1,7&11 are masked 4201H Lines 1,10&15 are masked 0841H Lines 1,7&12 are masked 8201H Lines 1,10&16 are masked 1041H Lines 1,7&13 are masked 0C01H Lines 1,11&12 are masked 2041H Lines 1,7&14 are masked 1401H Lines 1,11&13 are masked 4041H Lines 1,7&15 are masked 2401H Lines 1,11&14 are...
Page 228
Page 8 of 18 NECA 340-414-220 Revision 2.0 SPR-011 MCU 5000A Multipoint Control Unit 1.5M LIF CLOCK SOURCE SETTING LINE RELATED SYSTEM PARAMETERLINE NUMBER TO BE MASKEDSYSTEM PARAMETERLINE NUMBER TO BE MASKED 0807H Lines 1,2,3&12 are masked 2013H Lines 1,2,5&14 are masked 1007H Lines 1,2,3&13 are masked 4013H Lines 1,2,5&15 are masked 2007H Lines 1,2,3&14 are masked 8013H Lines 1,2,5&16 are masked 4007H Lines 1,2,3&15 are masked 0063H Lines 1,2,6&7 are masked 8007H Lines 1,2,3&16 are masked 00A3H Lines...
Page 229
NECA 340-414-220 Revision 2.0 Page 9 of 18 MCU 5000A Multipoint Control Unit SPR-011 1.5M LIF CLOCK SOURCE SETTING LINE RELATED SYSTEM PARAMETERLINE NUMBER TO BE MASKEDSYSTEM PARAMETERLINE NUMBER TO BE MASKED 0503H Lines 1,2,9&11 are masked A003H Lines 1,2,14&16 are masked 0903H Lines 1,2,9&12 are masked C003H Lines 1,2,15&16 are masked 1103H Lines 1,2,9&13 are masked 001FH Lines 1,2,3,4&5 are masked 2103H Lines 1,2,9&14 are masked 002FH Lines 1,2,3,4&6 are masked 4103H Lines 1,2,9&15 are masked 004FH...
Page 230
Page 10 of 18 NECA 340-414-220 Revision 2.0 SPR-011 MCU 5000A Multipoint Control Unit 1.5M LIF CLOCK SOURCE SETTING LINE RELATED SYSTEM PARAMETERLINE NUMBER TO BE MASKEDSYSTEM PARAMETERLINE NUMBER TO BE MASKED 0067H Lines 1,2,3,6&7 are masked 4087H Lines 1,2,3,8&15 are masked 00A7H Lines 1,2,3,6&8 are masked 8087H Lines 1,2,3,8&16 are masked 0127H Lines 1,2,3,6&9 are masked 0307H Lines 1,2,3,9&10 are masked 0227H Lines 1,2,3,6&10 are masked 0507H Lines 1,2,3,9&11 are masked 0427H Lines 1,2,3,6&11 are...