MCU 5000A Multipoint Control Unit SPR-011
1.5M LIF CLOCK SOURCE SETTING
LINE RELATED
SUMMARY:
Specifies the line from which to extract the line clock to be used inside the MCU 
5000A.  When set to “auto”, the line whose line signal is the first to turn normal 
will be specified as the clock source, but it will be replaced by the lowest-
numbered line currently in normal operation once the line acting as the clock 
source then ceases being normal.  When all the...

Page 222

Page 2 of 18 NECA 340-414-220 Revision 2.0
SPR-011 MCU 5000A Multipoint Control Unit
1.5M LIF CLOCK SOURCE SETTING
LINE RELATED
STEP PROCEDURE 
SYSTEM PARAMETER CLOCK SOURCE (CH) SYSTEM PARAMETER CLOCK SOURCE (CH)
00H
Automatic (automatic 
selection of line in its 
numerical order)09H 9
01H 1 0AH 10
02H 2 0BH 11
03H 3 0CH 12
04H 4 0DH 13
05H 5 0EH 14
06H 6 0FH 15
07H 7 10H 16
08H 8 80H Internal
[2] System parameter values on setting the clock source mask for the addresses 3CH and 3DH.  
The factory...

Page 223

NECA 340-414-220 Revision 2.0 Page 3 of 18
MCU 5000A Multipoint Control Unit SPR-011
1.5M LIF CLOCK SOURCE SETTING
LINE RELATED
Note:
  Marking a line as masked omits it from automatic selection if 3B = 00
SYSTEM 
PARAMETERLINE NUMBER TO BE MASKEDSYSTEM 
PARAMETERLINE NUMBER TO BE MASKED
0000H No lines masked 0201H Lines 1&10 are masked
0001H Line 1 is masked 0401H Lines 1&11 are masked
0002H Line 2 is masked 0801H Lines 1&12 are masked
0004H Line 3 is masked 1001H Lines 1&13 are masked
0008H Line 4 is...

Page 224

Page 4 of 18 NECA 340-414-220 Revision 2.0
SPR-011 MCU 5000A Multipoint Control Unit
1.5M LIF CLOCK SOURCE SETTING
LINE RELATED
SYSTEM 
PARAMETERLINE NUMBER TO BE MASKEDSYSTEM 
PARAMETERLINE NUMBER TO BE MASKED
0084H Lines 3&8 are masked 0210H Lines 5&10 are masked
0104H Lines 3&9 are masked 0410H Lines 5&11 are masked
0204H Lines 3&10 are masked 0810H Lines 5&12 are masked
0404H Lines 3&11 are masked 1010H Lines 5&13 are masked
0804H Lines 3&12 are masked 2010H Lines 5&14 are masked
1004H Lines 3&13 are...

Page 225

NECA 340-414-220 Revision 2.0 Page 5 of 18
MCU 5000A Multipoint Control Unit SPR-011
1.5M LIF CLOCK SOURCE SETTING
LINE RELATED
SYSTEM 
PARAMETERLINE NUMBER TO BE MASKEDSYSTEM 
PARAMETERLINE NUMBER TO BE MASKED
8040H Lines 7&16 are masked 4400H Lines 11&15 are masked
0180H Lines 8&9 are masked 8400H Lines 11&16 are masked
1280H Lines 8&10 are masked 1800H Lines 12&13 are masked
0480H Lines 8&11 are masked 2800H Lines 12&14 are masked
0880H Lines 8&12 are masked 4800H Lines 12&15 are masked
1080H Lines...

Page 226

Page 6 of 18 NECA 340-414-220 Revision 2.0
SPR-011 MCU 5000A Multipoint Control Unit
1.5M LIF CLOCK SOURCE SETTING
LINE RELATED
SYSTEM 
PARAMETERLINE NUMBER TO BE MASKEDSYSTEM 
PARAMETERLINE NUMBER TO BE MASKED
8003H Lines 1,2&16 are masked 8009H Lines 1,4&16 are masked
00D0H Lines 1,3&4 are masked 0031H Lines 1,5&6 are masked
0015H Lines 1,3&5 are masked 0051H Lines 1,5&7 are masked
0025H Lines 1,3&6 are masked 0091H Lines 1,5&8 are masked
0045H Lines 1,3&7 are masked 0111H Lines 1,5&9 are masked
0085H...

Page 227

NECA 340-414-220 Revision 2.0 Page 7 of 18
MCU 5000A Multipoint Control Unit SPR-011
1.5M LIF CLOCK SOURCE SETTING
LINE RELATED
SYSTEM 
PARAMETERLINE NUMBER TO BE MASKEDSYSTEM 
PARAMETERLINE NUMBER TO BE MASKED
0441H Lines 1,7&11 are masked 4201H Lines 1,10&15 are masked
0841H Lines 1,7&12 are masked 8201H Lines 1,10&16 are masked
1041H Lines 1,7&13 are masked 0C01H Lines 1,11&12 are masked
2041H Lines 1,7&14 are masked 1401H Lines 1,11&13 are masked
4041H Lines 1,7&15 are masked 2401H Lines 1,11&14 are...

Page 228

Page 8 of 18 NECA 340-414-220 Revision 2.0
SPR-011 MCU 5000A Multipoint Control Unit
1.5M LIF CLOCK SOURCE SETTING
LINE RELATED
SYSTEM 
PARAMETERLINE NUMBER TO BE MASKEDSYSTEM 
PARAMETERLINE NUMBER TO BE MASKED
0807H Lines 1,2,3&12 are masked 2013H Lines 1,2,5&14 are masked
1007H Lines 1,2,3&13 are masked 4013H Lines 1,2,5&15 are masked
2007H Lines 1,2,3&14 are masked 8013H Lines 1,2,5&16 are masked
4007H Lines 1,2,3&15 are masked 0063H Lines 1,2,6&7 are masked
8007H Lines 1,2,3&16 are masked 00A3H Lines...

Page 229

NECA 340-414-220 Revision 2.0 Page 9 of 18
MCU 5000A Multipoint Control Unit SPR-011
1.5M LIF CLOCK SOURCE SETTING
LINE RELATED
SYSTEM 
PARAMETERLINE NUMBER TO BE MASKEDSYSTEM 
PARAMETERLINE NUMBER TO BE MASKED
0503H Lines 1,2,9&11 are masked A003H Lines 1,2,14&16 are masked
0903H Lines 1,2,9&12 are masked C003H Lines 1,2,15&16 are masked
1103H Lines 1,2,9&13 are masked 001FH Lines 1,2,3,4&5 are masked
2103H Lines 1,2,9&14 are masked 002FH Lines 1,2,3,4&6 are masked
4103H Lines 1,2,9&15 are masked 004FH...

Page 230

Page 10 of 18 NECA 340-414-220 Revision 2.0
SPR-011 MCU 5000A Multipoint Control Unit
1.5M LIF CLOCK SOURCE SETTING
LINE RELATED
SYSTEM 
PARAMETERLINE NUMBER TO BE MASKEDSYSTEM 
PARAMETERLINE NUMBER TO BE MASKED
0067H Lines 1,2,3,6&7 are masked 4087H Lines 1,2,3,8&15 are masked
00A7H Lines 1,2,3,6&8 are masked 8087H Lines 1,2,3,8&16 are masked
0127H Lines 1,2,3,6&9 are masked 0307H Lines 1,2,3,9&10 are masked
0227H Lines 1,2,3,6&10 are masked 0507H Lines 1,2,3,9&11 are masked