NEC Mcu 5000a Multipoint Control Unit Equipment Manual
Here you can view all the pages of manual NEC Mcu 5000a Multipoint Control Unit Equipment Manual. The NEC manuals for Communications System are available online for free. You can easily download all the documents as PDF.
Page 231
NECA 340-414-220 Revision 2.0 Page 11 of 18 MCU 5000A Multipoint Control Unit SPR-011 1.5M LIF CLOCK SOURCE SETTING LINE RELATED SYSTEM PARAMETERLINE NUMBER TO BE MASKEDSYSTEM PARAMETERLINE NUMBER TO BE MASKED 5007H Lines 1,2,3,13&15 are masked 802FH Lines 1,2,3,4,6&16 are masked 9007H Lines 1,2,3,13&16 are masked 00CFH Lines 1,2,3,4,7&8 are masked 6007H Lines 1,2,3,14&15 are masked 014FH Lines 1,2,3,4,7&9 are masked A007H Lines 1,2,3,14&16 are masked 024FH Lines 1,2,3,4,7&10 are masked C007H Lines...
Page 232
Page 12 of 18 NECA 340-414-220 Revision 2.0 SPR-011 MCU 5000A Multipoint Control Unit 1.5M LIF CLOCK SOURCE SETTING LINE RELATED SYSTEM PARAMETERLINE NUMBER TO BE MASKEDSYSTEM PARAMETERLINE NUMBER TO BE MASKED 060FH Lines 1,2,3,4,10&11 are masked 043FH Lines 1,2,3,4,5,6&11 are masked 0A0FH Lines 1,2,3,4,10&12 are masked 083FH Lines 1,2,3,4,5,6&12 are masked 120FH Lines 1,2,3,4,10&13 are masked 103FH Lines 1,2,3,4,5,6&13 are masked 220FH Lines 1,2,3,4,10&14 are masked 203FH Lines 1,2,3,4,5,6&14 are...
Page 233
NECA 340-414-220 Revision 2.0 Page 13 of 18 MCU 5000A Multipoint Control Unit SPR-011 1.5M LIF CLOCK SOURCE SETTING LINE RELATED SYSTEM PARAMETERLINE NUMBER TO BE MASKEDSYSTEM PARAMETERLINE NUMBER TO BE MASKED 091FH Lines 1,2,3,4,5,9&12 are masked C01FH Lines 1,2,3,4,5,15&16 are masked 111FH Lines 1,2,3,4,5,9&13 are masked 00FFH Lines 1,2,3,4,5,6,7&8 are masked 211FH Lines 1,2,3,4,5,9&14 are masked 017FH Lines 1,2,3,4,5,6,7&9 are masked 411FH Lines 1,2,3,4,5,9&15 are masked 027FH Lines 1,2,3,4,5,6,7&10...
Page 234
Page 14 of 18 NECA 340-414-220 Revision 2.0 SPR-011 MCU 5000A Multipoint Control Unit 1.5M LIF CLOCK SOURCE SETTING LINE RELATED SYSTEM PARAMETERLINE NUMBER TO BE MASKEDSYSTEM PARAMETERLINE NUMBER TO BE MASKED 063FH Lines 1,2,3,4,5,6,10&11 are masked 10FFH Lines 1,2,3,4,5,6,7,8&13 are masked 0A3FH Lines 1,2,3,4,5,6,10&12 are masked 20FFH Lines 1,2,3,4,5,6,7,8&14 are masked 123FH Lines 1,2,3,4,5,6,10&13 are masked 40FFH Lines 1,2,3,4,5,6,7,8&15 are masked 223FH Lines 1,2,3,4,5,6,10&14 are masked 80FFH...
Page 235
NECA 340-414-220 Revision 2.0 Page 15 of 18 MCU 5000A Multipoint Control Unit SPR-011 1.5M LIF CLOCK SOURCE SETTING LINE RELATED SYSTEM PARAMETERLINE NUMBER TO BE MASKEDSYSTEM PARAMETERLINE NUMBER TO BE MASKED 187FH Lines 1,2,3,4,5,6,7,12&13 are masked 81FFH Lines 1,2,3,4,5,6,7,8,9&16 are masked 287FH Lines 1,2,3,4,5,6,7,12&14 are masked 06FFH Lines 1,2,3,4,5,6,7,8,10&11 are masked 487FH Lines 1,2,3,4,5,6,7,12&15 are masked 0CFFH Lines 1,2,3,4,5,6,7,8,10&12 are masked 887FH Lines 1,2,3,4,5,6,7,12&16...
Page 236
Page 16 of 18 NECA 340-414-220 Revision 2.0 SPR-011 MCU 5000A Multipoint Control Unit 1.5M LIF CLOCK SOURCE SETTING LINE RELATED SYSTEM PARAMETE RLINE NUMBER TO BE MASKEDSYSTEM PARAMETE RLINE NUMBER TO BE MASKED 30FFH Lines 1,2,3,4,5,6,7,8,13&14 are masked 85FFH Lines 1,2,3,4,5,6,7,8,9,11&16 are masked 50FFH Lines 1,2,3,4,5,6,7,8,13&15 are masked 19FFH Lines 1,2,3,4,5,6,7,8,9,12&13 are masked 90FFH Lines 1,2,3,4,5,6,7,8,13&16 are masked 29FFH Lines 1,2,3,4,5,6,7,8,9,12&14 are masked 60FFH Lines...
Page 237
NECA 340-414-220 Revision 2.0 Page 17 of 18 MCU 5000A Multipoint Control Unit SPR-011 1.5M LIF CLOCK SOURCE SETTING LINE RELATED SYSTEM PARAMETERLINE NUMBER TO BE MASKEDSYSTEM PARAMETERLINE NUMBER TO BE MASKED 1BFFH Lines 1,2,3,4,5,6,7,8,9,10,12&13 are masked57FFH Lines 1,2,3,4,5,6,7,8,9,10,11,13&15 are masked 2BFFH Lines 1,2,3,4,5,6,7,8,9,10,12&14 are masked97FFH Lines 1,2,3,4,5,6,7,8,9,10,11,13&16 are masked 4BFFH Lines 1,2,3,4,5,6,7,8,9,10,12&15 are masked67FFH Lines 1,2,3,4,5,6,7,8,9,10,11,14&15...
Page 238
Page 18 of 18 NECA 340-414-220 Revision 2.0 SPR-011 MCU 5000A Multipoint Control Unit This page is for your notes.
Page 239
NECA 340-414-220 Revision 2.0 Page 1 of 2 MCU 5000A Multipoint Control Unit SPR-012 1.5M LIF LINE EQUALIZER SETTING LINE RELATED SUMMARY: Set the physical properties of line. STEP PROCEDURE Note: When connecting to a T1 line, set the equalizer value according to the cable distance. In the case of an NTT line, however, fix the value to “EQL-A” before use. The line equalizer can be set independently for each line. 1 Enter the following command. SSPR__ n1 = x1 __n2 = x2 __ … ni = xi … ¿ ni: System...
Page 240
Page 2 of 2 NECA 340-414-220 Revision 2.0 SPR-012 MCU 5000A Multipoint Control Unit 1.5M LIF LINE EQUALIZER SETTING LINE RELATED STEP PROCEDURE xi:System parameter values See below: [2] System parameter values on setting the line equalizer for the addresses 40H to 4FH. The factory shipment value for the system parameter applicable to all the lines is 00H. SYSTEM PARAMETER LINE EQUALIZER 00H EQL-A (0 to 133 feet) 01H EQL-B (133 to 267 feet) 02H EQL-C (267 to 400 feet) 03H EQL-D (400 to 533 feet) 04H...