NECA 340-414-220 Revision 2.0 Page 1 of 2
MCU 5000A Multipoint Control Unit SPR-103
VIDEO CAPABILITY SETTING
TERMINAL CAPABILITY RELATED
SUMMARY:
Set the H.261 defined video capability.
STEP PROCEDURE 
Note:
Set the video capability with the factory shipment value (22H 02H
).  If change is necessary 
for any reason, follow the steps described below.
1 Enter the following command.
SSPR__ n1 =  x1 __n2 = x2 __ … ni = xi … ¿
ni:
System parameter addressA:  208H and 209H
B:  268H and 269H
[1] Video...

Page 362

Page 2 of 2 NECA 340-414-220 Revision 2.0
SPR-103 MCU 5000A Multipoint Control Unit
VIDEO CAPABILITY SETTING
TERMINAL CAPABILITY RELATED
STEP PROCEDURE 
x
i:
System parameter values See below:
[1] System parameter values on setting the video capability for the addresses 108H 
and 109H.
The factory shipment value for the system parameter is 22H 02H
.
SYSTEM PARAMETER 
VIDEO CAPABILITY ADDRESS
A: 209H
B: 269HADDRESS
A: 208H
B: 268H
00H 05H QCIF: 4/29.79 is ON
00H 09H QCIF: 3/29.79 is ON
00H 11H QCIF:...

Page 363

NECA 340-414-220 Revision 2.0 Page 1 of 2
MCU 5000A Multipoint Control Unit SPR-104
LSD CAPABILITY SETTING
TERMINAL CAPABILITY RELATED
LSD Capability (A: +20AH ~ 20BH) (B: +26AH ~ +26BH)
b7
b6b5
b4 b3 b2 b1 b0
b2 : 1200 bps
b3 : 4800 bpsDefault = 00H A: +20AH
00
0 fixed0000 fixed
0 fixed
b4 : 6400 bps
b6 : 9600 bps B: +26AH
b7 : 14,400 bps
b7
b6b5
b4 b3 b2 b1 b0
Default = 00H 0 fixed0 fixed
0 fixed0 fixed 0 fixed
0 fixed
0 fixed0 fixed A: +20BH
B: +26BH 

Page 364

Page 2 of 2 NECA 340-414-220 Revision 2.0
SPR-104 MCU 5000A Multipoint Control Unit
This page is for your notes. 

Page 365

NECA 340-414-220 Revision 2.0 Page 1 of 2
MCU 5000A Multipoint Control Unit SPR-105
HSD CAPABILITY SETTING
TERMINAL CAPABILITY RELATED
HSD Capability (A: +20CH ~ 20FH) (B: +26CH ~ +26FH)
b7
b6b5
b4 b3 b2 b1 b0
Default = 00H 0 fixed0 fixed
0 fixed0 fixed 0 fixed
0 fixed
0 fixed0 fixed A: +20CH
B: +26CH
b7
b6b5
b4 b3 b2 b1 b0
Default = 00H 0 fixed000
0
0 A: +20DH
B: +26DH
b1 : 64 kbps
b2 : 128 kbps
b3 : 192 kbps
b4 : 256 kbps
b6 : 384 kbps
Note:  When distributing HSD date, bit will be 1.0 fixed
0 fixed...

Page 366

Page 2 of 2 NECA 340-414-220 Revision 2.0
SPR-105 MCU 5000A Multipoint Control Unit
This page is for your notes. 

Page 367

NECA 340-414-220 Revision 2.0 Page 1 of 2
MCU 5000A Multipoint Control Unit SPR-106
MLP CAPABILITY SETTING
TERMINAL CAPABILITY RELATED
MLP Capability (A: +210H ~ 211H) (B: +270H ~ +271H)
b7
b6b5
b4 b3 b2 b1 b0
Default = 00H 0 fixed0 fixed
0 fixed0 fixed 0 fixed
0
00 fixed A: +210H
B: +270H
b1 : MLP-4k
b2 : MLP-6k
b7
b6b5
b4 b3 b2 b1 b0
Default = 00H 0 fixed0 fixed
0 fixed0 fixed 0 fixed
0 fixed
0 fixed0 fixed A: +211H
B: +271H 

Page 368

Page 2 of 2 NECA 340-414-220 Revision 2.0
SPR-106 MCU 5000A Multipoint Control Unit
This page is for your notes. 

Page 369

NECA 340-414-220 Revision 2.0 Page 1 of 2
MCU 5000A Multipoint Control Unit SPR-107
NETWORK CLASSIFICATION CAPABILITY SETTING
TERMINAL CAPABILITY RELATED
Network Classification Capability (A: +212H ~ 213H) (B: +272H ~ +273H)
b7
b6b5
b4 b3 b2 b1 b0
Default = 00H 0 fixed0 fixed
0 fixed0 fixed 0 fixed
00 fixed A: +212H
B: +272H
b1 : 56 kbps (restricted)0 fixed
b7
b6b5
b4 b3 b2 b1 b0
Default = 00H 0 fixed0 fixed
0 fixed0 fixed 0 fixed
0 fixed
0 fixed0 fixed A: +213H
B: +273H 

Page 370

Page 2 of 2 NECA 340-414-220 Revision 2.0
SPR-107 MCU 5000A Multipoint Control Unit
This page is for your notes. 