NECA 340-414-220 Revision 2.0 Page 1 of 2 MCU 5000A Multipoint Control Unit SPR-032 MLP CAPABILITY SETTING TERMINAL CAPABILITY RELATED SUMMARY: MCU 5000A communicates with terminals (VisuaLink ADs) via MLP channels. STEP PROCEDURE Note: Set the MLP capability with the factory shipment value (06H 00H) . If change is necessary for any reason, follow the steps described below. 1 Enter the following command. SSPR__ n1 = x1 __n2 = x2 __ … ni = xi … ¿ ni: System parameter address110 H and 111 H [1]...
Page 322
Page 2 of 2 NECA 340-414-220 Revision 2.0 SPR-032 MCU 5000A Multipoint Control Unit MLP CAPABILITY SETTING TERMINAL CAPABILITY RELATED STEP PROCEDURE SYSTEM PARAMETER MLP CAPABILITY ADDRESS 111 HADDRESS 11 0 H 00H 00H OFF 00H 02H MLP-4K: ON 00H 04H MLP-6.4 K: ON 00H 06H MLP-4 K and MLP-6.4 K: ON 2 Verify that the normal response is displayed with “OK ”. If YES , go to Step 3 . If NO , go to Step 1 . 3 End of procedure.
Page 323
NECA 340-414-220 Revision 2.0 Page 1 of 2 MCU 5000A Multipoint Control Unit SPR-033 NETWORK CLASSIFICATION CAPABILITY SETTING TERMINAL CAPABILITY RELATED SUMMARY: When communicating with a network having its basic line capacity restricted to 56 kb/s such as ACCUNET in North America, set “56 kb/s (restricted)” to ON. If all the networks are in 64 kb/s, set it to OFF. STEP PROCEDURE 1 Enter the following command. SSPR__ n1 = x1 __n2 = x2 __ … ni = xi … ¿ ni: System parameter address112 H and 113H...
Page 324
Page 2 of 2 NECA 340-414-220 Revision 2.0 SPR-033 MCU 5000A Multipoint Control Unit NETWORK CLASSIFICATION CAPABILITY SETTING TERMINAL CAPABILITY RELATED STEP PROCEDURE 2 Verify that the normal response is displayed with “OK ”. If YES , go to Step 3 . If NO , go to Step 1 . 3 End of procedure.
Page 325
NECA 340-414-220 Revision 2.0 Page 1 of 2 MCU 5000A Multipoint Control Unit SPR-035 MBE CAPABILITY SETTING TERMINAL CAPABILITY RELATED SUMMARY: MCU 5000A uses MBE to expand NEC original function. STEP PROCEDURE Note: Use the MBE capability with the factory shipment value (01H 00H ) as a general rule. If change is necessary for any reason, follow the steps described below. 1 Enter the following command. SSPR__ n1 = x1 __n2 = x2 __ … ni = xi … ¿ ni: System parameter address116 H and 117H [1]...
Page 326
Page 2 of 2 NECA 340-414-220 Revision 2.0 SPR-035 MCU 5000A Multipoint Control Unit MBE CAPABILITY SETTING TERMINAL CAPABILITY RELATED STEP PROCEDURE 2 Verify that the normal response is displayed with “OK ”. If YES , go to Step 3 . If NO , go to Step 1. 3 End of procedure.
Page 327
NECA 340-414-220 Revision 2.0 Page 1 of 2 MCU 5000A Multipoint Control Unit SPR-036 MBE MESSAGE (AUDIO) CAPABILITY SETTING TERMINAL CAPABILITY RELATED SUMMARY: Set the expansion audio capability of connecting CODEC (VL 5000). STEP PROCEDURE Note: Use the MBE message (audio) capability with the factory shipment value (00H 00H ). If change is necessary for any reason, follow the steps described below. 1 Enter the following command. SSPR__ n1 = x1 __n2 = x2 __ … ni = xi … ¿ ni: System parameter...
Page 328
Page 2 of 2 NECA 340-414-220 Revision 2.0 SPR-036 MCU 5000A Multipoint Control Unit MBE MESSAGE (AUDIO) CAPABILITY SETTING TERMINAL CAPABILITY RELATED STEP PROCEDURE 2 Verify that the normal response is displayed with “OK ”. If YES , go to Step 3 . If NO , go to Step 1 . 3 End of procedure.
Page 329
NECA 340-414-220 Revision 2.0 Page 1 of 2 MCU 5000A Multipoint Control Unit SPR-037 MBE MESSAGE (LSD2) CAPABILITY SETTING TERMINAL CAPABILITY RELATED SUMMARY: Set the expansion LSD2 capability of connecting CODEC (VL 5000). STEP PROCEDURE Note: MCU 5000A does not support LSD2. Use the MBE message (LSD2) capability with the factory shipment value (00H 00H ). If change is necessary for any reason, follow the steps described below. 1 Enter the following command. SSPR__ n1 = x1 __n2 = x2 __ … ni = xi...
Page 330
Page 2 of 2 NECA 340-414-220 Revision 2.0 SPR-037 MCU 5000A Multipoint Control Unit MBE MESSAGE (LSD2) CAPABILITY SETTING TERMINAL CAPABILITY RELATED STEP PROCEDURE SYSTEM PARAMETER MBE MESSAGE (LSD2) ADDRESS 11 B HADDRESS 11 A H 00H 00H NONE 00H 01H 1200 b/s 00H 04H 4800 b/s 00H 05H 1200 b/s and 4800 b/s 00H 08H 9600 b/s 00H 09H 1200 b/s and 9600 b/s 00H 0CH 4800 b/s and 9600 b/s 00H 0DH 1200 b/s, 4800 b/s, and 9600 b/s 2 Verify that the normal response is displayed with “OK ”. If YES , go to Step 3...