Wait for paging queues to be empty? [Y]:(Press Enter key here)Line states (A-active, I-idle, S-stopped) for module 1 (s1ot:pot-t)39-S 3:l -S 3:2-I Message Indicator Request Queue Lengths active:0 untried:0 retrying:0 calls expected:0 Paging Request Queue Lengths active:0 untried:0 retrying:0 calls expected:0 **** SHUTDOWN COMPLETE **** cp: Copying lusr/vmiconfigltcp.init to iusrivmlconfigitcp.init.oldcp: Copying /usr/vm/config/tcp.init.O to /usr/vm/configltcp.initcp: Copying lusr/vmiconfigltcp.host to...
Page 422
6.2.Step 2 - Configure the Enhanced In-Band ApplicationAfter the line group is set to run the Enhanced in-band application, configuration is required for the application to work correctly. The previous steps left the system at the VoiceMemo Configuration - Main Menu prompt.(Enter S - R - R from the Main Menu.) VOICEMEMO CONFIGURATION _ MAIN MENU (40%CC)CD)(E)F)wPCwActivate Configuration Hardware Configuration Increase System Hours Define Floating Modules Modify Active Configuration Modify Inactive...
Page 423
2.Enter A to select Configure Application. The system displays the Enhanced In-bandmenu: ENHANCED IN-BAND (N)Application Name = []0)Application Description = []CT)Edit Templates MenuP)Edit Parameters Menu(0)Show Application(1)Install Application CL)List Applications (VSave ApplicationPaExit ti Enter N to select Application Name. This name will be used to install the application later in this procedure (refer to page 23).Application Name - [] EIB-2OOD = Enter an Application Name (EIB-200D in this...
Page 424
3 Press Enter to re-display Template 1, and check that the information you entered iS correct:IN-BAND EDIT TEMPLATE Menu (M)Modify Template - [ 11(D) Data - [RI(A)Action - [T](T)Timeout - [I(E)Error Action - [](N)Next Templates - [Z 3 4 5 6 71(C)Comment - [Answer call and run templates 2,3,4,5,6 and 71(X) Exit EDIT TEMPLATE MENU (M.D.A.T.E,N,C,X):Current Template - [I] 3 Enter M to select Modify Template option. Enter 2 to select template 2:EDIT TEMPLATE MENU (M.D.A.T.E.N.C.X):(Press Enter key to...
Page 425
* Enter M to select Modify Template option. Enter 3 to select template 3:EDIT TEMPLATE MENU (M,D.A.T,E,N,C,X):(Press Enter key to expand menu) + Press Enter to display Template 3 in its expanded form:IN-BAND EDIT TEMPLATE Menu (M)Modify Template - [3](D)Data - [](A)Action - [](T)Timeout - [](E)Error Action - [I(N)Next Templates - [](C)Comment - [](X) Exit 5.Enter the following information for Template 3:EDIT TEMPLATE MENU: D Data - [] 622#dX#Sx#EDIT TEMPLATE MENU (M.D.A,T.E.N.C,X): A Action - []...
Page 426
6. Enter the following information for Template 4: EDIT TEMPLATE MENU: D Data - [I 633#dx#sx#EDIT TEMPLATE MENU (M.D.A.T,E.N.C,X): AAction - [] V3EDIT TEMPLATE MENU (M,D.A.T.E.N.C.X): TTimeout- [] 10EDITTEMPLATE MENU (M,D,A.T,E.N.C.X): E Error Action- [] H EDIT TEMPLATE MENU (M,D,A.T.E.N,C,X): c Comment -[I Call Forward No-Answer (External) EDIT TEMPLATE MENU (M,D,A.T.E,N,C,X): 3 Press Enter to re-display Template 4 and check that the information you entered is correct:IN-BAND EDITTEMPLATE Menu...
Page 427
3 Press Enter to re-display Template 5 and check that the information you entered is correct:IN-BAND EDIT TEMPLATE Menu (M)Modify Template - [5](D)Data - [623#dx#sx#](A)Action - [V3](T)Timeout - [lo](E)Error Action - [H](N)Next Templates - [](C)Comment - [Call Forward No-Answer (External)] (X) Exit EDIT TEMPLATE MENU (M.D,A,T,E,N,C.X):Current Template - [I] + Enter M to select Modify Template option. Enter 6 to select template 6:EDIT TEMPLATE MENU (M.D.A,T.E.N,C,X):(Press Enter key t(;! expand menu) +...
Page 428
3 Enter M to select Modify Template option. Enter 7 to select template 7: EDIT TEMPLATE MENU (M,D.A,T,E.N,C.X):(Press Enter key to expand menu) 3 Press Enter to display Template 7 in its expanded form: IN-BAND EDIT TEMPLATE Menu (M)Modify Template - [7](D)Data - [](A)Action - [](T)Timeout - [](E)Error Action - [](N)Next Templates - [](C)Comment - [](X) Exit 9. Enter the following information for Template 7: EDIT TEMPLATE MENU: DData - [I ###EDIT TEMPLATE MENU (M.D.A,T.E,N.C,X): A Action- [] I/EDIT...
Page 429
10.Enter 0 to Show Application. Ensure that all Templates are set up correctly:NAME: EIB-2OODDESCRIPTION: MIT-EL ENHANCED INTEGRATION Installation Date: Mon Feb 5 12:36: 12 1996 Last Modify Date: Wed Apr 24 15:22:46 1996 Tl: R, T. ,Next: 2 3 4 5 6 IComment: Answer call and run templates 2.3.4.5.6 and 7 TZ: 622#dx#sx#. V4, 10, HNext:Comment: Call Forward Busy (External) T3: 622#dx#sx#, V3. 10. H Next: Comment: Call Forward Busy (Internal) T4: 633#dx#sx#. V3. 10. HNext:Comment: Call Forward No-Answer...
Page 430
1. Enter I to select Install Application:Application name to install - E/&200D 3 Enter the Application Name. The name is case sensitive and must be entered exactly as it appears in the application name field. In this example, the name is EIB-200D (refer to page 17). 2.Enter S to save application. The system prompts for the following:Do you want to overwrite existing copy? (YIN): Y =a Enter Y to confirm the overwrite:Application saved. IN-BAND MENU (N,D.T.P,O.I,L.S,X): 3. Enter X to Exit and return to...