Page 441
0 1996 Centigram Communications Corporation. All rights reserved. This publication is protected by federal copyright law. No part of this publication may be copied or distributed, stored in a retrieval system, or translated into any human or computer language in any form or by any means electronic, mechanical, magnetic, manual or otherwise, or disclosed to third parties without the express written permission of Centigram Communications Corporation, 91 East Tasman Drive, San Jose, CA 95134. REPRODUCTION...
Page 442
MITEL MAILTM on the SX-2000@ PABX Contents OVERVIEW . . . . . . . . . . . . . . ..*............................................................................................................................4GENERAL . . . . . . . ..‘........................~...........................................................................................................4REQUIREMENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ....
Page 443
OVERVIEW This document is intended to show the necessary hardware connectivity to the MITEL SX-2000@PABX, as well as to define the Customer Data Entry (CDE) requirements to integrate the MITEL MAILTM system with the PBX. GENERAL Full integration between the M/T,!3 MA/L system and the SX-2000 is achieved through the use of the “Enhanced In-band” signaling application on M/TEL MAIL, and Advanced Analog Networking (AAN) on the SX-2000 system. Enhancements are as follows: ‘bConditional Greetings can be...
Page 444
., . . REQUIREMENTSl M/TEL MA/L includes “Receptionist II” and “Enhanced In-band” signaling as part of the basic package.l PBX software MS2007 MR3 (N16.1.1) is required for the Digital E&M (Tl E&M) interface.l Minimum software load of MS2007 MR2 (Nil .4.0) is required to support full functionality. The following feature packages must be purchased on the PBX, as required: B Advanced Analog Networking .Required on the Voice Mail PBX for Enhanced In-band signaling or Direct Subscriber Login. NOTE:1....
Page 445
HARDWARE INTERFACEBThe MIKEL MAIL system interfaces to the SX-2000 family of PBXs via Type I - E&M trunks (analog or digital) for call processing, and QNS port(s) for message activation/deactivation. See Notes below. BReceptionist II and VoiceMemo functionality is performed on the same E&M trunk ports through the use of AAN and Enhanced in-band signaling. BPager Notification and FaxMemo require additional dedicated ONS port(s). E&M ports can be used, but this is not practical from a hardware real estate...
Page 446
SX-2000 ICS PROGRAMMING1.Feature Access Code Assignment Call Hold - Retrieve*11 Call Forwarding - Busy (External)*62 Call Forwarding - Busy (Internal)*63 Call Forwarding - Follow Me*64 Call Forwarding -No-Answer (External)*65 Call Forwarding -No-Answer (Internal)*66 Message Waiting - Activate*90 Message Waiting - Deactivate*91 NOTE: These FACs are programmable and are referenced when programming the 2. M/TEL MAIL database (see page 13).Class of Service Call Forwarding (External Destination) Call...
Page 447
System Options Assignment Call Rerouting Timer (5-60 s)22(default - must be greater than Call Forward No-Answer, and less than No-Answer Recall timers) Ringing Cadence for Tie Line Calls (Internal/External)Internal(required if M/TEL MA/L performs screened transfers) Disable End of Dial Character (#) (Yes/No)No 4.ONSlOPS Circuit Descriptor Assignment Default values can be assigned for the ONS voice mail ports which will be used for Messaging, Pager Notification or FaxMemo. Single line sets on the PBX,...
Page 448
9.E&M Trunk Circuit Descriptor Assignment Address Signaling Incoming Start Type Disconnect Timer Minimum Flash Timer (loo-250 ms) Maximum Flash Timer (200-250 ms) Outgoing Start Type Fake Answer Supervision After Outpulsing Ignore Answer Supervision Release Supervision Expected Audio Inhibit Until Answer Supervision Transmission Facility (2 Wire/4 Wire)DTMF IMM 300(must be greater than the “Maximum Flash Timer”)100 250 IMM Yes Yes Yes No 2 Wire NOTE: The E&M trunks on the PBX must be strapped for Type...
Page 449
Program the Route Assignment, referencing the proper Trunk Group and Digit Modification Number. Digits Before Outpulsing can be set to eliminate overlap outpulsing, but should not be required.Automatic Route Selection Assignment Leading Digits: 81 Second Dial Tone: NoCOR Group Number: Digits DialedDigits to Follow TypeNumber 0Route01 NOTE: All access to M/TEL MA/L will follow this single ARS entry. *.13.System Speed Call Assignment Program a system speed call number which contains the ARS access to the...
Page 450
MITEL MAIL HARDWARE Strap the line card ports for E&M and ONS as required. The Smart Card may alternatively be used for Message Waiting. MITEL MAIL PROGRAMMING The M/TEL MA/L system must be programmed to integrate to the SX-2000 for proper call handling. The following programming details are to assist you in setting up Templates for the Enhanced In-band signaling application. For other basic programming, such as Message Waiting, refer to M/TEL MA/L Volume 2, Reference and Configuration. Define Line...