Home > Mitel > Communications System > Mitel Sx 50 Dpabx Instructions Guide

Mitel Sx 50 Dpabx Instructions Guide

Here you can view all the pages of manual Mitel Sx 50 Dpabx Instructions Guide. The Mitel manuals for Communications System are available online for free. You can easily download all the documents as PDF.

Page 561

Customer Data Entry (CDE) 
COMMANDS 501 - 580 Trunk Programming -Slots 1 + 10 
(Cont’d) - 
Register 6 
a 
b c d e f g h i-j 
6 
1 1 0 4 1 
a: 
Register Number 
b: 
DID Start Type 
0 = Immediate Start 
1 = Wink Start 
2 = Delay Dial 
c: RESERVED 
d: 
Incoming Address Signaling 
0 = Loop-Dial Pulsing 
1 = Battery-and-Ground Pulsing 
2 = DTMF 
e: N : 
Number Of Digits Expected (1 - 9) 
f: M : 
Number Of Digits To Be Absorbed (0 - 8) 
Cl- j: X : Digits To Be Inserted 
Note: 
In orderto change the number of...

Page 562

cau 
Customer Data Entry Registers 
COMMANDS 501 - 580 Trunk Programming - Slots 1 - 10 
(Cont’d) 
Register 7 
a: 
Register Number 
b,c: Incoming Seizure Debounce Timer 
(01 - 15)xiOms 
d: Wink Timer 
(3 - 6) x 50 ms 
e: Permanent-Signal Partial-Dial Timer 
(1 - 6) x 5 set 
f: 
DID Disconnect Timer 
(3 - 6) x 50 ms 
cl- i: Release Acknowledge Timer 
002 - 120 set 
9104-091-210-NA Issue 5 
Revision 0 
210 4-51  

Page 563

Customer Data Entry (CDE) 
Verified Authorization Code Programming 
4.15 Command 600 is used to program Verified Authorization codes (VAC) on the SX-50 
system. Verified Authorization codes are required by the following features: Traveling 
COS and Special DISA. Refer to Section 9104-091-l 05:NA, TRAVELING COS and 
Section 9104-091-l 05-NA, SPECIAL DISA, for further details. 
COMMAND 600 VERIFIED AUTHORIZATION CODE PROGRAtiMIN6 
a,b,c: Register Number 001 - 999 
d: 
VAC Activation 
0 = Disable 
1 =...

Page 564

w 
Customer Data Entry Registers 
ARS Programming 
4.16 Commands 700 through 745 and 750 through 752 apply to the SX-50 system’s 
Automatic Route Selection package. For detailed information refer to Section 
9104-091-220-NA, Automatic Route Selection. 
COMMAND 700 ARS DIGIT COMPARISON TABLE PROGRAMMING 
si _ 
a,b,c: Entry Number 001 - 800 
d,e: Time-of-Day Table Number 01 -+ 45 
9’ I: Dialed Digits String (field scrolls to provide up to 32 digits) 
COMMANDS 701 + 745: ARS TIME-OF-DAY TABLE PROGRAMMING 
a...

Page 565

Customer Data Entry (CDE) 
COMMAND 750 ARS ROUTE LIST TABLE PROGRAMMING 
a 
b c d e f g h i j k I m n o 
- - - - - - - -. - - 
- - 
a,b,c: Route List Number 001 - 200 
d,e,f: 1 st Choice Route Number 
. 
g,h,i: 2nd Choice Route Number 
j,k,l: 
3rd Choice Route Number 
m,n,o: 4th Choice Route 
COMMAND 751 ARS ROUTE TABLE PROGRAMMING 
a 
b c d e f g h 
0 0 0 0 0 
a,b,c: Route Number 001 - 100 
d: 
_ Trunk Group Number 1 - 6 
e,f,g: Digit Modification Entry Number 001 --+ 100 
h: Toll Calls 
0 = Non-Toll 
1...

Page 566

5 . 
PROGRAMMING ERRORS 
General 
5.1 The SX-50 system can detect certain errors made during CDE. The detection of a 
programming error results in a display similar to that shown in Figure 5-1, Alarm 
Message Format. The meaning of each code is listed in Table 2-2, Programming 
Error Codes. 
Exit From Error Mode 
5.2 
After the error code has been checked and the correct data determined, the 
programmer can exit the Error Mode by: 
4 pressing the QUIT softkey on the Attendant Console, 
OR, 
l pressing...

Page 567

Customer Data Entry (CDE) 
Table 5-l Programming Error Codes 
Error Code Description 
EOl Illegal Command identity 
E02 Digit keyed while Access Mode Error displayed 
E03 Directory Number already exists 
E04 Data out of range 
E05 Illegal Directory Number length 
E06 Directory Number range insufficient 
E07 Too many digits keyed 
E08 Illegal Device range 
E09 Write.protected command 
El0 Insufficient software package level 
El1 Write protected data 
El2 Data field incomplete 
El3 RESERVED 
El4 Maximum...

Page 568

Programming Errors 
Table 5-l Programming Error Codes 
(continued) 
Error Code Dkscription 
E33 Attempt to display System Security Code 
E34 Attempt to display User Security Code 
E35 Attempt to display DISA Access Code 
E36 RESERVED 
E37 Specified card type not found in slot position _ 
E38 Attempt to overflow current Trunk Group 
E39 Invalid Trunk Number keyed 
E40 Invalid Auxiliary Attendant Equipment (must be a SUPERSETTelephone) 
E41 Auxiliary Attendant not idle. 
E42 Auxiliary Attendant Programming...

Page 569

Customer Data Entry (CDE) 
210 5-4 Revision 0 9104-091-210-NA issue 5  

Page 570

issue 5 
March, 1993 
SX-50@ DIGITAL PRIVATE 
AUTOMATIC BRANCH EXCHANGE 
(DPABX) 
~ __... -~~--~..~. .- ~- ..~.~. ~~-~- -- _---- 
Automatic 
Route 
Selection and 
Toll Control 
_..-___-.---- 
&,F- d Tra emark of Mite1 Corporation. 
opyright 1993, MM Corporation. 
All rights reserved. 
Printed in Canada. 
@ 
MITEL?  
Start reading Mitel Sx 50 Dpabx Instructions Guide