Page 531
Customer Data Entry (CDE) Register 4 a bcdefghij 4 1 1 1 1 0 0 0 0 0 b: Call Forward - Follow Me 0 = Disable all Call Forwarding 1 = Allow forwarding of trunks or extensions to internal numbers only 2 = Allow forwarding of extensions only to internal or external numbers 3 = Allow forwarding of trunks or extensions to internal or external numbers c: Call Forward - Busy 0 = Disable all Call Forwarding 1 = Allow forwarding of trunks or extensions to internal numbers only 2 = Allow forwarding of...
Page 532
.,. Yy Customer Data Entry Registers COMMANDS 121 - 129 COS 1 - COS 9 Programming (Cont’d) Register 5 a b c d e f g hi j k 5 1 1 1 1 1 1 1 1 ; 0 b: Abbreviated Dial Numbers 10 - 19 or 100 - 199 0 = Disable 1 = Enable . c: Abbreviated Dial Numbers 20 - 29 or 200 - 299 0 = Disable 1 = Enable d: Abbreviated Dial Numbers 30 - 39 or 300 - 399 0 = Disable 1 = Enable e: Abbreviated Dial Numbers 40 - 49 or 400 - 499 0 = Disable 1 = Enable f: Abbreviated Dial Numbers 50 - 59 or 500 - 599 0 =...
Page 533
Customer Data Entry (CDE) Register 6 b: c: NOT USED Outgoing Access To E&M Tie Trunks 0 = Disable 1 = Enable d: Outgoing Access To CO Trunks 0 = Disable 1 = Enable Register 7 b: c: d: e: f: 9: 210 4-22 SUPERSET 4ISUPERSET 420 Message Programming 0 = Disable 1 = Enable Account Code Entry 0 = Not allowed 1 = Optional 2 = Required for Toll Calls Only 3 = Required for all Calls (Toll & Non-Toll) Auxiliary Attendant Position 0 = Disable 1 = Enable Directed Call Pickup 0 = Disable...
Page 534
yo Customer Data Entry Registers h: Lockout Alarm 0 = Disable 1 = Enable Register 8 a b c d e f g 8 11 10 0 0 b: Extension Camp-on 0 = Disable 1 = Enable c: CO Trunk Camp-on 0 = Disable 1 = Enable d: Inward Dial Trunk Camp-on 0 = Disable 1 = Enable e: DID Restriction 0 = Disable 1 = Enable Trunk Group Programming 4.5 The Trunk Group Programming commands set parameters and feature options that apply only to the trunks in the Trunk Group. In all cases there are default values; the...
Page 535
Customer Data Entry (CDE) Identified Trunk Group: After any trunk in an identified trunk group has been seized outgoing, it outpulses the trunk group access code before the digits dialed at the calling telephone. This option is applicable to some types of networking. Wait for Dial Tone: Outpulsing of the dialed digits begins when dial tone is received or 5 seconds after trunk seizure, whichever is sooner. The other options are: l dial after a programmed delay of up to 5 seconds, l check for dial...
Page 536
cau Customer Data Entry Registers d: Overflow Trunk Group 0 = Disable 1 - 6 = Trunk Group Number e: Identified Trunk Group 0 = Disable 1 = Enable f - i: Trunk Group Access Code Defaults: Cmd151 =9,Cmd152=8, Cmd153=78,Cmd154=79 Cmd 155 = blank, Cmd 156 = blank Register 2 a bcdefghijk 20020000000 b: Wait For Dial Tone 0 = No wait, outpulse after delay 1 = Wait up to 5 seconds, then outpulse anyway 2 = Check for dial tone every 5 seconds 3 = Unlimited wait with detection by user c:...
Page 537
Customer Data Entry (CDE) h: Simulate CO Dial Tone 0 = Disable 1 = Enable . . I. Trunk Group SMDR Enable 0 = Disable 1 = Enable . . J- Trunk Group Last Number Redial 0 = Disable 1 = Enable k: Trunk Group Manual E&M Trunk 0 = Disable 1 = Enable Register 3 b: Message Registration 0 = Disable 1 = Enable C:. Count Additional Message Units 0 = Disable 1 = Enable 2 = Enable, Insert Pseudo Message Unit every 6 Seconds 3 = Enable, Insert Pseudo Message Unit every 60 Seconds d,e: Initial...
Page 538
au Customer Data Entry Registers c: Behind PABX Operation 0 = Disable 1 = Enable, Flash is Loop Disconnect 2 = Enable, Flash is Ring Ground d: Behind PBX Recall Signal Duration 0 = 500 ms 1 = 750 ms e: Credit Card Calling Operation 0 = Disable 1 = Enable User Programming Access 4.6 The User Programming Access registers determine which command registers may be modified by the system user entering CDE with the User Security Code. They do not affect installer access via the System Security...
Page 539
Customer Data Entry (CDE) 0 = Disable 1 = Enable Register 2 a bcdefgh - 2 0 0 0 0 0 0 0 b: c: d: e: f: 9: h: Commands 361 --, 366, Extension Hunting _ 0 = Disable 1 = Enable Command 381, Ring Group Programming 0 = Disable 1 = Enable Commands 401 --z 480, SUPERSET Telephone Programming 0 = Disable 1 = Enable Commands 501 - 580, Trunk Programming 0 = Disable 1 = Enable Commands 151 -+ 156, Trunk Group Programming 0 = Disable 1 = Enable Commands 700 --, 752, ARS Data Table...
Page 540
Customer Data Entry Registers d: Command 191, User Security Code Programming 0 = Disable 1 = Enable e: Command 193, DISA Access Code Programming 0 = Disable 1 = Enable f: Command 192, RMATS Security Code Programming 0 = Disable Note: Fields c and fare always disabled and cannot be modified- 9104-091-210-NA Issue 5 Revision 0 210 4-29