Page 521
Customer Data Entry (CDE) COMMAND JO0 System Options Programming (Cont’d) Timeout Selection a,b: c: d: e: f: 9: h: Register Number _ Timed Recall - Camp-On (Trunks) l-7 XlOseconds Timed Recall - No Answer 1 - 7 X 10 seconds Timed Recall - Call Hold (Extension) 1 -+ 4 X 1 minute Timed Recall - Call Hold (Attendant) 1 - 7 X 10 seconds Call Forward No Answer Timeout 1 - 7 X 10 seconds Drop Unanswered Trunks After 5 Minutes 0 = Disable, 1 = Enable Message Waiting a,b: Register Number c:...
Page 522
UIfl Customer Data Entry Registers COMMAND 100 System Options Programming (Cont’d) Automatic Route Selection (ARS) a b c d e f g h’i j 13 0 0 0 0 0 0 1.0 a,b: Register Number 0 = Disable 1 = Enable c: ARS Enable 0 = Disable 1 = Enable d: ARS Attendant Bypass d = Disable 1 = Enable e: ARS Alarms 0 = Disable 1 = Enable f: ARS Return Dial Tone 0 = Disable 1 = Enable Expensive Route Warning Tone 0 = Disable 1 = Enable h: Attendant ARS Routing Class of Service (RCS) 0 = ARS Does Not...
Page 523
Customer Data Entry (CDE) COMMAND 100 System Options Programming (Cont’d) System Message Detail Recording (SMDR) a bcdefghijk 14000000000 a,b: c: d: e: f: 9: h: k: Register Number SMDR System Enable 0 = Disable . 1 = Enable Incoming Trunks Calls Only 2 = Enable Outgoing Trunks Calls Only 3 = Enable Both Incoming and Outgoing Trunk Calls Record Meter Pulses Long Call Indicator 0 = Disable 1 = Enable Incoming Calls Record Only COs 0 = Disable 1 = Enable Drop Calls Of Less Than 8...
Page 524
.- u1?1 Customer Data Entry Registers Account Code Control a,b: Register Number c: Number of Digits (maximum if Variable Length enabled) 0 = Disable Account Codes l-8=1 - 8 digits d: Variable Length Account Codes 0 = Disable 1 = Enable e: Verified Authorization Codes (VACj 0 = Disable l-8=1 --, 8 digits Note: All VACs must be deleted prior to changing VAC length. 9104-091-210-NA Issue 5 Revision 0 210 4-13
Page 525
Customer Data Entry (CDE) COMMAND 100 System Options Programming (Cont’d) Printer Control pjgqg$q -’ a,b: Register Number c: Data Demultiplexer Enable (0 = Disable, 1 = Enable) d: Printer Baud Rate ’ O=llO 1=150 2 = 300 3 = 600 4 = 1200 5 = 1800 6 = 2400 7 = 4800 8 = 9600 e: Printer Parity 0 = None 1 = Odd 2 = Even f: Number of TX Bits 5 - 8 Number of Stop Bits 1 or 2 h: Slow Carriage Return Option 0 = Disable 1 = Output Six Nulls at End-of-Line Contact Monitor a b c d e 1 7 0...
Page 526
au Customer Data Entry Registers Feature Access Code Programming COMMAND 110 I Feature I Access Code I DIAL ACCESS TO ATTENDANT PAGING ACCESS CALL HOLD CALL HOLD RETRIEVE - LOCAL CALL HOLD RETRIEVE - REMOTE DIAL CALL PICKUP SYSTEM ABBREVIATED DIAL ACCESS CALL FORWARD - FOLLOW ME TAFAS PICKUP CALL FORWARD - NO ANSWER CALL FORWARD - BUSY CALL FORWARD - BUSY/NO ANSWER PROGRAMMING ACCESS ATTENDANT FUNCTIONS CLEAR ALL FEATURES CALL PARK (AlTENDANT) 1 CALL PARK (ATTENDANT) 2 CALL PARK...
Page 527
Customer Data Entry (CDE) COMMAND 110 COMMAND 110 Feature Access Code Programming (Cont’d) Feature Access Code Programming (Cont’d) I Feature I Access Code I HUNT GROUP 3 ACCESS HUNT GROUP 3 ACCESS HUNT GROUP 4 ACCESS HUNT GROUP 4 ACCESS HUNT GROUP 5 ACCESS HUNT GROUP 5 ACCESS HUNT GROUP 6 ACCESS HUNT GROUP 6 ACCESS RING GROUP ACCESS RING GROUP ACCESS RMATS MODEM ACCESS RMATS MODEM ACCESS ONS MSG WAITING ACTIVATE ONS MSG WAITING ACTIVATE ACCOUNT CODE ENTRY ACCOUNT CODE ENTRY...
Page 528
w Customer Data Entry Registers Class of Service (COS) Programming 4.4 The Class of Service Programming commands set parameters and feature options that apply only to the devices in that COS. In all cases there are default values; the installer need only perform data entry where a change from the default value is desired. The COS Programming command numbers are 121 through 129, corresponding to COSs 1 through 9. - COMMANDS 121 - 129 COS I- COS 9 PROGRAMMING Register 1 a b end e f g hi j 11...
Page 529
Customer Data Entry (CDE) COMMANDS 121 - 129 COS 1 - COS 9 Programming (Cont’d) Register 2 a b c d e f g h i-j k 21100010000 b: Switchhook/Ground Button Flash 0 = Disable 1 = Flash For Consultation Hold 2 = Flash For Test Line/Attendant c: Call Direction 0 = Originate only 1 = Bothway calling 2 = Receive Only d: Automatic Ringdown Circuit 0 = Disable 1 = Enable e: DISA Access Code Required 0 = Disable 1 = Enable 2 = Special DISA / VAC Required f: Message Registration/Restrictive...
Page 530
- - Customer Data Entry Registers COMMANDS 121 - 129 COS 1 --, COS 9 Programming (Cont’d) Register 3 a b c d e f g h’ i j k 311010100~10 b: c: Automatic Callback Busy/No Answer 0 = Disable, 1 = Enable Paging Access 0 = Disable, 1 = Enable d: Data Line Security 0 = Disable, 1 = Enable e: Call Hold 0 = Disable, 1 = Enable f: Call Block 0 = Disable, 1 = Enable TAFAS Access 0 = Disable 1 = Enable Pickup From Night Bells 2 = Enable Pickup From Night Bells/Attendant h: COS SMDR 0 =...