Home > Mitel > Communications System > Mitel Sx 50 Dpabx Instructions Guide

Mitel Sx 50 Dpabx Instructions Guide

Here you can view all the pages of manual Mitel Sx 50 Dpabx Instructions Guide. The Mitel manuals for Communications System are available online for free. You can easily download all the documents as PDF.

Page 521

Customer Data Entry (CDE) 
COMMAND JO0 System Options Programming (Cont’d) 
Timeout Selection 
a,b: 
c: 
d: 
e: 
f: 
9: 
h: Register Number 
_ 
Timed Recall - Camp-On (Trunks) l-7 XlOseconds 
Timed Recall - No Answer 1 
- 7 X 10 seconds 
Timed Recall - Call Hold (Extension) 1 -+ 4 X 1 minute 
Timed Recall - Call Hold (Attendant) 1 
- 7 X 10 seconds 
Call Forward No Answer Timeout 1 
- 7 X 10 seconds 
Drop Unanswered Trunks After 5 Minutes 0 = Disable, 1 = Enable 
Message Waiting 
a,b: Register Number 
c:...

Page 522

UIfl 
Customer Data Entry Registers 
COMMAND 100 System Options Programming (Cont’d) 
Automatic Route Selection (ARS) 
a b c d e f g h’i j 
13 0 0 0 0 0 0 1.0 
a,b: Register Number 
0 = Disable 
1 = Enable 
c: ARS Enable 
0 = Disable 
1 = Enable 
d: ARS Attendant Bypass 
d = Disable 
1 = Enable 
e: ARS Alarms 
0 = Disable 
1 = Enable 
f: ARS Return Dial Tone 
0 = Disable 
1 = Enable 
Expensive Route Warning Tone 
0 = Disable 
1 = Enable 
h: Attendant ARS Routing Class of Service (RCS) 
0 = ARS Does Not...

Page 523

Customer Data Entry (CDE) 
COMMAND 100 System Options Programming (Cont’d) 
System Message Detail Recording (SMDR) 
a 
bcdefghijk 
14000000000 
a,b: 
c: 
d: 
e: 
f: 
9: 
h: 
k: Register Number 
SMDR System Enable 
0 = Disable . 
1 = Enable Incoming Trunks Calls Only 
2 = Enable Outgoing Trunks Calls Only 
3 = Enable Both Incoming and Outgoing Trunk Calls 
Record Meter Pulses 
Long Call Indicator 
0 = Disable 
1 = Enable 
Incoming Calls Record Only COs 
0 = Disable 
1 = Enable 
Drop Calls Of Less Than 8...

Page 524

.- 
u1?1 
Customer Data Entry Registers 
Account Code Control 
a,b: Register Number 
c: Number of Digits (maximum if Variable Length enabled) 
0 = Disable Account Codes 
l-8=1 - 8 digits 
d: Variable Length Account Codes 
0 = Disable 
1 = Enable 
e: Verified Authorization Codes (VACj 
0 = Disable 
l-8=1 --, 8 digits 
Note: 
All VACs must be deleted prior to changing VAC length. 
9104-091-210-NA Issue 5 
Revision 0 210 4-13  

Page 525

Customer Data Entry (CDE) 
COMMAND 100 System Options Programming (Cont’d) 
Printer Control 
pjgqg$q -’ 
a,b: Register Number 
c: Data Demultiplexer Enable (0 = Disable, 1 = Enable) 
d: 
Printer Baud Rate ’ 
O=llO 
1=150 
2 = 300 
3 = 600 
4 = 1200 
5 = 1800 
6 = 2400 
7 = 4800 
8 = 9600 
e: Printer Parity 
0 = None 
1 = Odd 
2 = Even 
f: Number of TX Bits 5 - 8 
Number of Stop Bits 1 or 2 
h: Slow Carriage Return Option 
0 = Disable 
1 = Output Six Nulls at End-of-Line 
Contact Monitor 
a b c d e 
1 7 0...

Page 526

au 
Customer Data Entry Registers 
Feature Access Code Programming 
COMMAND 110 
I Feature 
I Access Code 
I 
DIAL ACCESS TO ATTENDANT 
PAGING ACCESS 
CALL HOLD 
CALL HOLD RETRIEVE - LOCAL 
CALL HOLD RETRIEVE - REMOTE 
DIAL CALL PICKUP 
SYSTEM ABBREVIATED DIAL ACCESS 
CALL FORWARD - FOLLOW ME 
TAFAS PICKUP 
CALL FORWARD - NO ANSWER 
CALL FORWARD - BUSY 
CALL FORWARD - BUSY/NO ANSWER 
PROGRAMMING ACCESS 
ATTENDANT FUNCTIONS 
CLEAR ALL FEATURES 
CALL PARK (AlTENDANT) 1 
CALL PARK (ATTENDANT) 2 
CALL PARK...

Page 527

Customer Data Entry (CDE) 
COMMAND 110  COMMAND 110 Feature Access Code Programming (Cont’d)  Feature Access Code Programming (Cont’d) 
I Feature 
I Access Code 
I 
HUNT GROUP 3 ACCESS  HUNT GROUP 3 ACCESS 
HUNT GROUP 4 ACCESS  HUNT GROUP 4 ACCESS 
HUNT GROUP 5 ACCESS  HUNT GROUP 5 ACCESS 
HUNT GROUP 6 ACCESS  HUNT GROUP 6 ACCESS 
RING GROUP ACCESS  RING GROUP ACCESS 
RMATS MODEM ACCESS  RMATS MODEM ACCESS 
ONS MSG WAITING ACTIVATE  ONS MSG WAITING ACTIVATE 
ACCOUNT CODE ENTRY  ACCOUNT CODE ENTRY...

Page 528

w 
Customer Data Entry Registers 
Class of Service (COS) Programming 
4.4 The Class of Service Programming commands set parameters and feature options 
that apply only to the devices in that COS. In all cases there are default values; the 
installer need only perform data entry where a change from the default value is 
desired. The COS Programming command numbers are 121 through 129, 
corresponding to COSs 1 through 9. - 
COMMANDS 121 - 129 COS I- COS 9 PROGRAMMING 
Register 1 
a 
b end e f g hi j 
11...

Page 529

Customer Data Entry (CDE) 
COMMANDS 121 - 129 COS 1 - COS 9 Programming (Cont’d) 
Register 2 
a b c d e f g h i-j k 
21100010000 
b: Switchhook/Ground Button Flash 
0 = Disable 
1 = Flash For Consultation Hold 
2 = Flash For Test Line/Attendant 
c: Call Direction 
0 = Originate only 
1 = Bothway calling 
2 = Receive Only 
d: Automatic Ringdown Circuit 
0 = Disable 
1 = Enable 
e: DISA Access Code Required 
0 = Disable 
1 = Enable 
2 = Special DISA / VAC Required 
f: Message Registration/Restrictive...

Page 530

 - - 
Customer Data Entry Registers 
COMMANDS 121 - 129 COS 1 --, COS 9 Programming (Cont’d) 
Register 3 
a b c d e f g h’ i j k 
311010100~10 
b: 
c: Automatic Callback Busy/No Answer 
0 = Disable, 1 = Enable 
Paging Access 
0 = Disable, 1 = Enable 
d: Data Line Security 
0 = Disable, 1 = Enable 
e: Call Hold 
0 = Disable, 1 = Enable 
f: Call Block 
0 = Disable, 1 = Enable 
TAFAS Access 
0 = Disable 
1 = Enable Pickup From Night Bells 
2 = Enable Pickup From Night Bells/Attendant 
h: COS SMDR 
0 =...
Start reading Mitel Sx 50 Dpabx Instructions Guide

Related Manuals for Mitel Sx 50 Dpabx Instructions Guide

All Mitel manuals