Mitel Sx 50 Dpabx Instructions Guide
Here you can view all the pages of manual Mitel Sx 50 Dpabx Instructions Guide. The Mitel manuals for Communications System are available online for free. You can easily download all the documents as PDF.
Page 492
1 ’ INTndDUCTlON General 1.1 After the successful mechanical installation of the SX-50s system (refer to Section 9104-091-200-NA, Shipping, Receiving and Installation Information), the system is ready for programming. This Section outlines the procedures for entering customer data, describes the programming options, and indicates the-default options. Reason for Reissue 4 1.2 This section has been reissued to incorporate MS55 software. Section Overview 1.3 This Section is divided into five...
Page 494
2 ’ SYSTEM INITIALIZATION AND DATA ENTRY Default Data 2.1 When the system is first installed, the default database must be loaded. Refer to Table 2-1, Initial Power-up Procedure. The default database saves programming time, as the programmer need make entries only where a deviation from the default is desired. The default database sets up an operable telephone system when power-up is completed. Installed Line and COV card ports are assigned extension numbers in ascending order starting at 100...
Page 495
Customer Data Entry (CDE) .. Programming Access 2.3 If Status Switch 1 is CLOSED, press # (or dial 70) at the Console or Test Line. If the switch is OPEN, follow the procedure inTable 2-3, Programming Access from the Attendant Console or Table 24, Programming Access from the Test Line. Table 2-l Initial Power-up Procedure INITIAL POWER-UP AND LOAD DEFAULT DATA With the system power OFF, set all the Control Card status switches OPEN. Refer to Figure 2-1, Control Card Connectors, or Figure k-2,...
Page 496
System Initialization and Data Entry Table 2-3 Programming Access From The Attendant Console ENTER PROGRAMMING MODE FROM THE ATTENDANT CONSOLE Note: For read-only access, omit the steps involving the STATUS key. m Press and hold down the STATUS key. @ The Attendant Console LCD displays the software identifier and maintenance release number. sx-50 MS53-MRO ) Enter a security code (System Security Code default is 7772 and User Security Code default is 1234) .* b The Attendant Console LCD flashes...
Page 497
Customer Data Entry (CDE) ‘Table 24 Programming Access From The Test Line ENTER PROGRAMMING MODE FROM THE TEST LINE 1. Status Switch 2 on the Control Card must be CLOSED for Test Line operation. 2. It is recommended that a SUPERSET’” 4 telephone be used as aTest Line as it has an LCD display. 3. Command 100 Register 1 fields e, f, g must be programmed with the equipment number of the Test Line set. Default is 001. . l Press # or dial 70. The SUPERSET 4 telephone LCD displays ENTER CODE and the...
Page 498
System Initialization and Data Entry TEST POINTS AC NIGHTBELL ‘II - I II I II / RESET SWITCH - RM32 PORl I II II (AilENDANT CONSOLE) .J4 II ‘ISEGMENT DISPLAY II ’ %iACTOR EDG BAR DDcm39 Figure 2-l Control Card Connectors 9104-091-210-NA issue 5 Revision 0 210 2-5
Page 499
Customer Data Entry (CDE) AC NIGHTBELL ‘11: J 11 1 11 , RESETSWITCH - II ’ W-232 PORT II \J4 (AnENOANT CONSOLE) II ‘ISEGMENT DISPLAY CARD EXTRACTOR ’ EOG EAR L Figure 2-2 Control Card 2 (MCCP) Connectors Selecting the Command Number OD0039 2.4 At the Command Level of CDE, the LCD shows a flashing command number and question mark. Refer to Figure 2-3, Command Level Display. 210 2-6 Revision 0 9104-091-210-NA Issue 5
Page 500
System initialization and Data Entry COMMAND 1 OO? ENTER EXIT Figure 2-3 CommancJ Level Display If required, dial a new command number on the telephdne keypad. The display stops flashing and the QUIT softkey appears. To correct an erroneous entry or change the command number again, press QUIT. When the required command number is displayed, press the ENTER softkey to enter Register Level. Selecting the Register Number 2.5 Upon entry to Register Level, the LCD displays the first register of the...