Page 461
Shipping, Receiving and Installation r . ‘i . . . ..- (6 AWG) 200 5-22 Figure 5-13(a) System Cabling Revision 0 9104-091-200-NA Issue 5
Page 462
Installation Procedures Figure 5-13(b) System Cabling 9104-091-200-NA Issue 5 Revision 0 200 5-23
Page 463
Shipping, Receiving and Installation . CARD HANDLE CABLE TIE DD0049 Figure 5-l 3(c) System Cabling 9-WIRE JACKS (CUSTOMER-PROVIDED) CABLE PROVIDED WITH CONTROL CARD ATENDANT CONSOLE MDFIPLANT WIRING S-WIRE CABLE (CUSTOMER-PROVIDED) 1, THE AlTENDANT CONSOLE CAN BE PLACED A MAXIMUM OF 200m FROM THE CONTROL CARD. 2. CONSOLE WIRING PAIRS (14.2-5, S-4) MUST BE KEPT AS PAIRS IN PLANT WIRING. DD0055 200 5-24 Figure 5-14 Remote Attendant Console Cable Installation Revision 0 9104-091-200-NA...
Page 464
Installation Procedures Chart 5-6 Attendant Console Installation Step Action Comments 1. Install Cable at Attendant Console. Refer to Figure 5-l 5, Cable Installa- l Insert the Attendant Console Cable into the tion on the Attendant Console. socket. Note: the Attendant Console can be placed up to 200 m (218 yd.) from the SX-50 System. 2. Install the Handset. l Plug one end of the Handset Cord into the Handset. Plug the other end of the Handset Cord into one of the two sockets on the left-...
Page 465
Shipping, Receiving and Installation - Chart 5-7 Miscellaneous Equipment installation Step Action Comments 1. Install the Customer-provided Night Bells Refer to Figure 5-16, Night Bell Con- Equipment. nections. l Connect the leads to the terminal block on the Control Card. l For ac Night Bells with a capacitor, terminate bell circuit between B and C. Connect termi- nals A and D together on the terminal block. l For ac Night Bells without a capacitor, termi- nate bell circuit between B and C....
Page 466
Installation Procedures TERMINAL BLOCK CROSS CONNECT CONTROL CARD FRAME AC NIGHT BELLS (WITH INTERNAL CAPACITOR) NIGH? BELL NIGHT BELL TERMINAL BLOCK CROSS CONNECT CONTROL CARD FRAME AC NIGHT BELLS (WITHOUT INTERNAL CAPACITOR) “p FRAME CROSS CONNECT TERMINA; BLOCK RELAYA [ ” REIAY B J.QURN C(NC’ NGING D(NC CONTROL CARD DC NIGHT BELLS DD0056 Figure 5-16 Night Bell Connections 9104-091-200-NA Issue 5 Revision 0 200 5-27
Page 467
. Shipping, Receiving and Installation Table 5-3 Printer Port Pin Assignments Pin 1 Source Assignment Not Used I I 2 Printer 1 RxD (Receive Data) -3 SC-50 System TxD (Transmit Data) 4 Printer RTS (Request to Send) - 5 SX-50 System CTS (Clear to Send) I 6 I 1 Not Used 7 Common GND (Ground) 8* 25 Not Used Table 5-4 Control Card Status Switch Functions 1 Switch Number 1 Function I 1 OPEN - Programming: Security Code Required CLOSED - Programming: No Security Code Required I 2 OPEN -...
Page 468
Installation Procedures MDF MUSIC ON HOLD/PAGER MODULE ----- ----- NOTES: 1. PIN DESIGNATIONS SHOW MOH/PAGER MODULE IN FIRST POSITION OF UNIVERSAL CARD 2. THE SXS08 SYSTEM SUPPORTS ONE MOHlPAGER MODULE. I CONTROL CARD 2 I I I I. I I I I I I I TERMINAL BLOCK 4 I * 3 PAGER DDOO57 Figure 5-17 Music/Paging Connections 9104-091-200-NA Issue 5 Revision 0 200 5-29
Page 469
Shipping, Receiving and Installation - Chart 5-8 System Power-Up and Load Default Data Step Action Comments 1. Ensure the Power Supply is OFF. 2. Plug in the ac Power Cord. 3. Set all the Control Card Status Switches to Refer to Table 5-4, Control Card Sta- open. tus Switch Functions. 4. Install Attendant Console. (If required). 5. Switch Power Supply ON. 6. Load Default Data.Within 10 seconds after ? ap- If this does not occur, refer to Section pears on the Control Card LED (the Attendant...
Page 470
i- Installation Procedures moo37 Figure 5-18 Cover Installation 9104-091-200-NA Issue 5 Revision 0 200 5-31