3 ’ SHIPPING AND RECEIVING INFORMATION General n 3.1 Listed below are the contents of the cartons in which the SX-50 system is shipped. Upon delivery, check all items against the order form and packaging slip. Report any discrepancies immediately. The basic SX-50 system is shipped in the following boxes: l System carton. The carton is 51.4 cm (20.25 in.) high, 76.2 cm (30.0 in.) wide and 53.3 cm (21 in.) deep. The gross package weight is 16.00 kg (35.28 lb). (Refer to Figure 5-1, SX-50 System...
Page 433
Shipping, Receiving and Installation Cards u 3.3 The Control Card II, Generic Module and the peripheral cards are packaged in antistatic bags and protected with a layer of packaging foam. Included are the repair .tags and a caution notice describing static charge damage. Cards should not be unpacked before they are required for use. When required, they should be transported to the SX-50 system location packaged-in their original antistatic bags. Inspect each card to ensure that the printed circuit...
Page 434
Shipping and Receiving Information If the original packaging material is not available, then place the returned parts in antistatic bags, wrap in several layers of air-cushion type wrap, place in a suitable container and surround with paper to minimize movement of all items. piGiG- Precautions The Lithium battery is safe for normal use, but the following health and safety precautions must be observed: 1. Do not puncture, crush, or try to open the battery case. . 2. Do not burn the battery or...
Page 436
4 ’ INSTA-LLATION REQUIREMENTS Environmental Requirements 4.1 The SX-50 system must be vertically mounted on a wall. The location must meet the temperature limitations, space requirements and location constraints detailed below. Temperature Limitations 4.2 The temperature and humidity limits are: l Temperature 0” - 40” C (32” - 104” F) l Relative Humidity 10 - 90% (noncondensing). Space Requirements 4.3 The minimum space required for installation of the SX-50 system is shown in Figure 4-1,...
Page 437
Shipping, Receiving and Installation CID0054 200 4-2 Figure 4-l Space Requirements for the SXSO System Revision 0 9104-091-200-NA Issue 5
Page 438
Installation Requirements Power Supply Requirements 4.5 The customer must provide a dedicated single phase power receptacle, which should adhere to the following recommendations: l 115 V, 60 Hz, fused and capable of delivering a minimum of 5 A. l Should be wired and fused independently from all other receptacles. l Must not be controlled by a switch. l Must be a 3-wire type, with the third wire grounded to the ground of the electrical system. l Should be easily accessible for the removal of the...
Page 439
Shipping, Receiving and Installation (c) Do not share an enclosure or raceway between ac service wires bringing ac power to the system and any other system grounds, dc power distribution wires, or signal- ing wires. (d) All system hardware is provided with an ac fault return path to the system single point ground, which in turn is provided with a reliable path to the equipment ground- ing conductor (i.e., green wire ground or safety ground). (e) Refer to Appendix A for FCC Interconnection...
Page 440
5 . INSTALLATION PROCEDURES . General 5.1 The SX-50 system should be installed according to the steps detailed in the Installation Charts. A list of these charts is in Table 2-1, Installation Charts. Installation Charts 5.2 The following charts include all the information required to complete the installation of the SX-50 communications system. For programming information, refer to Section 9104-091-210-NA, Customer Data Entry. Table 5-l Installation Charts Title Chart Unpacking and Inspection...