Page 451
Shipping, Receiving and Installation GROUND LUG / - - / EDG BAR 1PAWG GROUND WIRE SPACER / 6 AWG SYSTEM GROUND WIRE (TO APPROVED GROUND) Figure 5-6 SX-50 System Grounding Revision 0 9104-091-200-NA Issue 5 200 5-12
Page 452
Installation Procedures Chart 54 Card and Module Installation Step Action Comments 1. Wear Static Protection Wrist Strap. _ Refer to Figure 5-7, Static Protection Wrist Strap. 2. Remove the required circuit cards and mod- Refer to Figure 5-2, Typical Printed ules from the antistaticbags. Circuit Card Packaging. 3. Install the Control Card. Refer to Figure 5-8, Control Card In- * Ensure that the Control Card is positioned car- stallation. _ rectly on the Backplate. l Ensure that the Control...
Page 453
Shipping, Receiving and Installation 200 5-14 Figure 5-7 Static Protection Wrist Strap Revision 0 9104-091-200-NA Issue 5
Page 454
Installation Procedures BAcKPlATE CARD FRAME DD0044 Figure 5-8 Control Card Installation 9104-091-200-NA Issue 5 Revision 0 200 5-15
Page 455
Shipping, Receiving and Installation - / f UTHIUM - BAnEMY CONTROL CARD / CONNECTOR . GENERIC MODULE Figure 5-9 Battery Installation 200 5-16 Revision 0 9104-091-200-NA Issue 5
Page 456
Installation Procedures GENERIC MODULE ‘. CONTROL CARD CONNECTOR Figure 5-10 Generic Module Installation 9104-091-200-NA issue 5 Revision 0 200 5-17
Page 457
Shipping, Receiving and Installation / CONTROL CARD , CARD FRAME PERIPHERAL CARD CONTROL CARD CARD FRAME / EDG POST / PERIPHERAL CARD Figure 5-l 1 Peripheral Card Installation 200 5-18 Revision 0 9104-091-200-NA Issue 5
Page 458
Installation Procedures MODULE J Figure 5-12 Universal Card Module Installation 9104-091-200-NA Issue 5 Revision 0 200 5-19
Page 459
Shipping, Receiving and Installation Switch Number Function 1 2 3 4 5 6 7 a Table 5-2 E&M Module Switch Functions OPEN - PBX to Line = +3 dB - CLOSED - PBX to Line = -13 dB I OPEN - Line to PBX = -4 dB CLOSED - Line to PBX = -11 dB OPEN - Complex Balance Enabled CLOSED - 600 Ohm Balance Enabled OPEN - 600 Ohm Balance Enabled CLOSED - Complex Balance Enabled . OPEN -4-Wire Operation CLOSED - 2-Wire Operation OPEN - Type 5 Signaling CLOSED -Type 1 Signaling NOT USED NOT USED...
Page 460
Installation Procedures Chart 5-5 System Cabling (continued) Step Action Comments 3. Connect Cables to Peripheral Cards. _ l Tighten the connector retaining screws. DO NOT over-tighten. l Dress each cable down the front of its periph- eral card. l Attach the cable to the handle with a cable tie. _ l Route cables to the MDF via a separate Cable Guide. 4. Secure all Cables. l Tie the cables in one bundle to the rear cross- web between card slots 7 and 8 under the cardframe. Leave enough...