Page 551
Customer Data Entry (CDE) COMMANDS 401 + 480 SUPERSET Telephone Programming a b c d e f g h i * ll---- * 1 for Key Number 01, 0 for Keys numbered 02 - 15 a,b: SUPERSET Telephone Key Number c: Line Appearance Type _ 0 = Speed Dial Key 1 = Prime Line (key 01 only - nonprogrammable) 2 = Key Line, 3 = Multiple Call Line 4 = Direct Trunk Select, 5 = Direct Line Select 6 = Private Line 7 =~ Personal Outgoing line 8 = Attendant Function Key (Auxiliary Attendant only) 9 = Message Waiting Key...
Page 552
- Customer Data Entry Registers Trunk Programming 4.12 The Trunk Programming commands set parameters and feature options that apply only to the particular trunk. In all cases there are default values; the installer need only perform data entry where a change from the default value is desired. Trunk Programming uses Commands 501 through 580, corresponding to trunk equipment numbers 1 through 80. Trunk Options 4.13 The following paragraphs explain trunk options. Trunk Group Membership A trunk...
Page 553
Customer Data Entry (CDE) l A DISA trunk can seize another trunk and make an outgoing call. l Trunks can hold a conference without involving any party internal to the PABX (i.e. an extension or console). The SX-50 system will not allow trunk connections where-no party provides Release Supervision. In a trunk conference, if the only party providing supervision hangs up, the conference is terminated. Inward Dial Delay Before Answer If this option is enabled, the SX-50 system will let trunks ring in...
Page 554
w Customer Data Entry Registers Start Type CBntral Office Trunks can provide Loop Start or Ground Start service. Loop Start trunks are seized by completing the dc current path across Tip and Ring. Ground Start trunks are seized by grounding the Ring lead. DID Start Type Depending on the serving central office, each DID trunk in the SX-50 system can be programmed for Immediate Start, Wink Start, or Delay Dial. Immediate Start is used with central offices that do not provide controlled address...
Page 555
Customer Data Entry (CDE) Dictation Trunk If selected, ‘this will retain the caller’s DTMF receiver for the duration of the call to perform tone-to-pulse conversions. Digits can be outpulsed at any time during the call. DID Trunk Timers 4.14 Commands 501 + 580, Register 7 specify various timer intervals for each DID Trunk. The following paragraphs explain the function of each timer. Incoming Seizure Debounce Timer This timer specifies the minimum duration of incoming seizure signal the SX-50...
Page 556
Yy Customer Data Entry Registers COMMANDS 501 - 580 Trunk Programming - Slots 1 - 10 Register 1 a b c d e f g h’ i j 1 * 1 @l 0 1 0 #.% * 1 for CO, 2 for E&M, 0 for DID @ 1 for CO, 3 for E&M, 6 for DID # 1 for CO, 2 for E&M, 3 for DID % 0 for CO, 1 for E&M, 2 for DID a: Register Number b: Trunk Group Membership 1 --, 6 (6 = Incoming Calls Only) c: Trunk Alarm Control 0 = Disable, 1 = Enable d: Trunk Hardware Type 0 = Short Analog CO Trunk 1 = Long Analog CO Trunk 2 = Analog Toll Office...
Page 557
Customer Data Entry (CDE) COMMANDS 501 - 580 Trunk Programming - Slots 1 - 10 (Cont’d) - Register 2 a b c d e f g h i 2 0 0 0 0 1 0 0 1 a: Register Number _ b: Trunk Outpulsing Break/Make Ratio 0 = 60/40 1 = 65/35 2 = 30120 3 = 35/15 c: Disconnect Supervision Guaranteed? 0 = No 1 = Yes d: Disappearance of Reversal 0 = is Ignored 1 = means Disconnect e: Reversal Meaning On Call Origination 0 = Not Incoming Call 1 = Incoming Call f: Disconnect Timing 0 = 60 msec 1 = 500 msec .2...
Page 558
u Customer Data Entry Registers COMMANDS 501 + 580 Trunk Programming - Slots 1 - IO (Cont’d) Register 3 b: Tie Line Disconnect Timer 0=150mi 1 = 300 ms c: E&M Lead Inversion Type 1 Type 5 o= M-Lead None I= Both E-Lead 2= None M-Lead 3= E-Lead Both d: E&M Delay Dial Outgoing 0 = Disable 1 = Enable e: E&M Wink Start Incoming 0 = Disable 1 = Enable f: E&M Wink Start Outgoing 0 =‘Disable 1 = Enable 9: RESERVED 9104-091-210-NA Issue 5 Revision 0 210 4-47
Page 559
Customer Data Entry (CDE) COMMANDS 501 - 580 Trunk Programming - Slots 1 - 10 (Cont’d) Register 4 a bcdefghijk 4051001000” * 0 for CO & DID Trunks, 1 for E&M Trunks a: Register Number b: Dictation Trunk (for LS/GS Trunks) 0 = Disable, 1 = Enable c: Inter-ringing Delay (for LS/GS Trunks) 3- 9 seconds d: Day Answer Mode Day Illegal Number Intercept (DID/DISA) 0 = Direct-In Line 1 = LDN 1 2=LDN2 3=LDN3 e,f,g: Day Answer Point (Day Answer Mode = 0) Day Inward Dial Trunk Intercept Answer...
Page 560
m Customer Data Entry Registers COMMANDS 501 - 580 Trunk Programming - Slots 1 - 10 (Cont’d) Register 5 a: Register Number b: Night Answer Mode Night Illegal Number Intercept (DID/DISA) 0 = Flexible Night Service 1 = LDN 1 2 = LDN 2 3=LDN3 c,d,e: Night Answer Point (Night Answer Mode = 0) Night Inward Dial Trunk Intercept Answer Point (DID/DISA) 000 = Night Bell 001 - 160 = Station Equipment Number 161 - 166 = Hunt Group Number 167 = Ring Group 168 = RMATS f: DID Night Answer Point...