Page 81
Shipping, Receiving, and Installation Information CHART 5-11 PFT KIT INSTALLATION INSTRUCTIONS - UNIVERSAL CABINET StepAction Comments 1.Unlock and open rear door of cabinet. 2.Attach antistatic wrist strap to your wrist andA PFT card is shown in Figure carefully unpack PFT card(s).5-13. 3.Power down system. 4.Place PFT card into the upper position, identify Following this sequence minimizes its two mounting holes on frame, and remove the chance of damaging a PFT card. Refer to Figure 5-14. card when...
Page 82
SECTION MITL9109-094-200-NACHART j-11 (CONT’D) PFT KIT INSTALLATION INSTRUCTIONS - UNIVERSAL CABINET StepAction Comments 14.Connect the ALARM pair of the IntercabinetDo not connect the intercabinetCable Assembly (672 port) to TBI-1 and TB’l-3 Cable Assembly (672 port) to J2 if of the lower (third) card in the Control cabinet; there are no PFT cards in the in the peripheral cabinet, connect thePeripheral cabinet. Intercabinet Cable Assembly (672 port) to TBl-2 and TBI-4 of the upper card. Connect the...
Page 83
Shipping, Receiving, and Installation Information . . . . . . . _ . . . . . 0 0 OPTIONAL LWGS CONVERSION MODULE FOR PFT CARD 8538E2R2Figure 5-13 Power Fail Transfer Card Page 75
Page 84
SECTION MITLSI 09-094-200-NA CARD FILELOOP START GROUND START CONVERTER TBlRIGHT HAND SIDE OF CABINET (FROM REAR) Figure 5-14 Locating PFT Card in an SX-200 Universal Cabinet Page 76
Page 85
Shipping, Receiving, and Installation Information1 - - 1 KAO700ROEOFigure 5-15 PFT Card Connections Page 77
Page 86
SECTION MITL9109-094-200-NACHART 5-12 INSTALL BAY 5 StepActionComments 1.Unpack shelf. Check backplane for cracks, bent pins, loose or missing items, and other damage. Check hardware against packing slip. Check fuses (if supplied). 2.Set POWER and BATTERY switches off and remove line cords from AC outlets. 3.Unlock and open front door. Attach ground wire to side of shelf before installing shelf into cabinet. 4.Place shelf onto shelf guides. 5.Fasten shelf to equipment cabinet using eight screws. 6.At...
Page 87
Shipping, Receiving, and Installation Information CHART 5-13 ANALOG PERIPHERAL CABINET RESERVE POWER SUPPLY INSTALLATION WARNING RESERVE SUPPLY IS FOR ANALOG PERIPHERAL CABINET ONLY. DO NOT ATTEMPT TO CONNECT IT TO CONTROL CABINET OR DIGITAL PERIPHERAL CABINET, WHICH REQUIRES A UPS. CAUTION: Check that the BATTERY switch on the reserve battery pack is set to OFF. Checkthat the three switches on the battery charging unit are set to OFF. StepAction Comments 1.Unpack reserve power supply equipment....
Page 88
SECTION MITL9109-094-200-NAStep 18. 19. 20. 21. 22. 23. 24. 25.Close and lock all cabinet doors. 26.Place cabinet in final position.CHART 5-13 (CONT’D) ANALOG PERIPHERAL CABINET RESERVE POWER SUPPLY INSTALLATION ActionComments Connect the Red, Black and Green leads. Route the charging unit power lead to the adapter, and plug the adapter into the receptacle on the rear door power supply. Plug system power cord into its receptacle. On Battery Pack, set BATTERY switch to ON. On Charging Unit, set AC switch...
Page 90
IlTLSl OS-094~ZOO-NACHART 5-17 INSTALL MAINTENANCE TERMINAL TO AN SX-200 CONTROL CABINET Action Unpack and install the maintenance terminal (VT-100 or equivalent) in its assigned position.Connect ;rn RS-232 cable betwetn the terminal and the local port on the maintenance panel on , the front of the system. If installing a remote terminal, connect a modem to the remote port on the maintenance panel, or on the power distribution panel at the lower rear of the cabinet (depending on cabinet type) Connect...