Shipping, Receiving, and Installation Information
PFT CABLE/
MEFINAL TOOTHLOCKWASHERSGROUND WIRE
/(CONNECTS TO
CABINET GROUND
STUD)
I
REAR CABLE
PANEL 
ASSEMBLV
AOAPTEk PLATE
(OPTIONAL)IPCM CABLES
(BAYS 4.5.6.7),NTERdBlNETCABLE ASSEMBLV
KA0683ElFigure 5-2 Installation of an Intercabinet Cable Assembly (672 port)
Page 53 

Page 62

SECTION MITL9109-094-200-NACHART 5-8
INSTALL AN ANALOG BAY 3 KIT INTO AN 
SX-ZOO CABINET
WARNING
THESE INSTRUCTIONS MUST BE FOLLOWED EXPLICITLY SINCE THEY INVOLVE WORK WITH AND
CHANGES TO THE PRIMARY POWER SUPPLY 
TC THE UNIT.
Only persons who have successfully completed a 
MITEL Installation and Maintenance training
course for the SX-200 DIGITAL PABX should perform this procedure.Step
1.ActionUnpack kit and inspect contents for loose,
damaged, or missing items.Comments
2.Open Control cabinet doors, set...

Page 63

Shipping, Receiving, and Installation InformationStepAction
9.
10.
11.
12.
13.
14.
15.
16.
17.CHART 5-8 (CONT’D)
INSTALL AN ANALOG BAY 3 KIT INTO AN SX-200 CABINET
CommentsInstall the PFT card below the Interconnectcard with six sets (8-32 x 
318” screws,
lockwashers, flat washers).The PFT card is optional.
Replace the Control shelf with its associated
hardware.Be sure that the antistatic wrist
strap is securely in its original
location.
Connect the wiring harness, 2nd
D.C., (pn 103148501) between the...

Page 64

SECTION MITL9109-094-200-NACHART 5-8 (CONT’D)
INSTALL AN ANALOG BAY 3 KIT INTO AN SX-200 CABINET
StepActionComments
18.Connect the DC power cable leads
to the Bay 3 backplane, as follows:TBI-1 purple (-10 V)
TBI-2 yellow (-5 V)
TBI-3 brown (0 V)
TBI-4 orange 
(+8 V)
TBI-5 nc
TB2-1 nc
TB2-2 gray (90 V)
TB2-3 nc
TB2-4 grn/yel (gnd to card file frame)
TB2-5 blue (-48 V)
19.Connect the DC power cable to the
Interconnect card as follows:
TB301-1 brown (0 V)
TB301-2 blue (-48 V)
TB301-3 braided gnd cable to...

Page 65

Shipping, Receiving, and installation Information
CHART 5-8 (CONT’D)
INSTALL AN ANALOG BAY 3 KIT INTO AN SX-200 CABINET
StepAction
Comments
25.Place rear door power supply onto shim
washer and lower door support and lock into
closed position (this will hold the rear door
power supply while installing upper support).
26.Install upper support over power supply hingepin and secure to cabinet with 4 sets (IO-32
screw, lockwasher).
27.Connect ground lead to cabinet ground stud
using hardware from original...

Page 66

SECTION MITL9109-094-200-NACHART 5-9
INSTALL AN ANALOG BAY 3 KIT INTO AN SX-200 UNIVERSAL CABINET
WARNING
THESE INSTRUCTIONS MUST BE FOLLOWED EXPLICITLY SINCE THEY INVOLVE WORK WITH AND
CHANGES TO THE PRIMARY POWER SUPPLY OF THE UNIT.
Only persons who have successfully completed a MITEL Installation and Maintenance training
course for the SX-200 DIGITAL PABX should perform this procedure.Step
1.ActionUnpack kit contents and inspect for loose,
damaged, or missing items. Refer to parts list.Comments
2.Open...

Page 67

Shipping, Receiving, and installation Information
CHART 5-g (CONT’D)
INSTALL AN ANALOG BAY 3 KIT INTO AN SX-200 UNIVERSAL CABINET
StepAction
Comments
12.Route the DC power cable (pn 114904501)Refer to Figure 4-7 and Figure
within the cabinet. The cable is routed up from 5-5.
the power supply, across the top of the
cabinet, and down to the terminal blocks on
’the backplane and Interconnect card.
13.Connect the DC power cable leads to
the Bay 3 backplane, as follows:
TBI-1 purple (-10 V)
TBI-2 yellow (-5...

Page 68

CHART 5-9 (CONT’D)INSTALL AN ANALOG BAY 3 KIT INTO AN SX-ZOO UNIVERSAL CABINET
StepActionComments
18.install a surge clamp onto the Bay 3 backplaneat slot 16, pins 9 to 32; ensure that surge
clamp is installed right side up (see label on
clamp).
19.Install cables between Bay 3 and distribution
frame.
20.Remove six screws that hold the rear cableRefer to Figure 5-6.
panel to cabinet; install lower door supportonto cabinet and secure with IO-32 screws in
eleventh hole from bottom, with the bracket
above...

Page 69

Shipping, Receiving, and Installation InformationStepActionIComments
29.
30.
31.
32.Remove the old hinge brackets for the rear
door from the cabinet frame.
33.Put on the antistatic wrist strap.
34.
35.
36.
StepAction
1.
2.
3.
4.
5.
6.CHART 5-9 (CONT’D)
INSTALL AN ANALOG BAY 3 KIT INTO AN 
SX-200 UNIVERSAL CABINET
CAUTION: This upgrade and installation procedure is to be performed only by qualified 
per-
Install rear door fan assembly and tighten two
nuts on hinge bracket.
Attach door ground wire from...

Page 70

SECTION MITLSI 09-094-200-NA, 
GREEN,
MOUNTINGrSCREWS1
KAll014ElRFigure 5-3 
Cardfile to Frame and Backplane Ground Connections