Page 61
Shipping, Receiving, and Installation Information PFT CABLE/ MEFINAL TOOTHLOCKWASHERSGROUND WIRE /(CONNECTS TO CABINET GROUND STUD) I REAR CABLE PANEL ASSEMBLV AOAPTEk PLATE (OPTIONAL)IPCM CABLES (BAYS 4.5.6.7),NTERdBlNETCABLE ASSEMBLV KA0683ElFigure 5-2 Installation of an Intercabinet Cable Assembly (672 port) Page 53
Page 62
SECTION MITL9109-094-200-NACHART 5-8 INSTALL AN ANALOG BAY 3 KIT INTO AN SX-ZOO CABINET WARNING THESE INSTRUCTIONS MUST BE FOLLOWED EXPLICITLY SINCE THEY INVOLVE WORK WITH AND CHANGES TO THE PRIMARY POWER SUPPLY TC THE UNIT. Only persons who have successfully completed a MITEL Installation and Maintenance training course for the SX-200 DIGITAL PABX should perform this procedure.Step 1.ActionUnpack kit and inspect contents for loose, damaged, or missing items.Comments 2.Open Control cabinet doors, set...
Page 63
Shipping, Receiving, and Installation InformationStepAction 9. 10. 11. 12. 13. 14. 15. 16. 17.CHART 5-8 (CONT’D) INSTALL AN ANALOG BAY 3 KIT INTO AN SX-200 CABINET CommentsInstall the PFT card below the Interconnectcard with six sets (8-32 x 318” screws, lockwashers, flat washers).The PFT card is optional. Replace the Control shelf with its associated hardware.Be sure that the antistatic wrist strap is securely in its original location. Connect the wiring harness, 2nd D.C., (pn 103148501) between the...
Page 64
SECTION MITL9109-094-200-NACHART 5-8 (CONT’D) INSTALL AN ANALOG BAY 3 KIT INTO AN SX-200 CABINET StepActionComments 18.Connect the DC power cable leads to the Bay 3 backplane, as follows:TBI-1 purple (-10 V) TBI-2 yellow (-5 V) TBI-3 brown (0 V) TBI-4 orange (+8 V) TBI-5 nc TB2-1 nc TB2-2 gray (90 V) TB2-3 nc TB2-4 grn/yel (gnd to card file frame) TB2-5 blue (-48 V) 19.Connect the DC power cable to the Interconnect card as follows: TB301-1 brown (0 V) TB301-2 blue (-48 V) TB301-3 braided gnd cable to...
Page 65
Shipping, Receiving, and installation Information CHART 5-8 (CONT’D) INSTALL AN ANALOG BAY 3 KIT INTO AN SX-200 CABINET StepAction Comments 25.Place rear door power supply onto shim washer and lower door support and lock into closed position (this will hold the rear door power supply while installing upper support). 26.Install upper support over power supply hingepin and secure to cabinet with 4 sets (IO-32 screw, lockwasher). 27.Connect ground lead to cabinet ground stud using hardware from original...
Page 66
SECTION MITL9109-094-200-NACHART 5-9 INSTALL AN ANALOG BAY 3 KIT INTO AN SX-200 UNIVERSAL CABINET WARNING THESE INSTRUCTIONS MUST BE FOLLOWED EXPLICITLY SINCE THEY INVOLVE WORK WITH AND CHANGES TO THE PRIMARY POWER SUPPLY OF THE UNIT. Only persons who have successfully completed a MITEL Installation and Maintenance training course for the SX-200 DIGITAL PABX should perform this procedure.Step 1.ActionUnpack kit contents and inspect for loose, damaged, or missing items. Refer to parts list.Comments 2.Open...
Page 67
Shipping, Receiving, and installation Information CHART 5-g (CONT’D) INSTALL AN ANALOG BAY 3 KIT INTO AN SX-200 UNIVERSAL CABINET StepAction Comments 12.Route the DC power cable (pn 114904501)Refer to Figure 4-7 and Figure within the cabinet. The cable is routed up from 5-5. the power supply, across the top of the cabinet, and down to the terminal blocks on ’the backplane and Interconnect card. 13.Connect the DC power cable leads to the Bay 3 backplane, as follows: TBI-1 purple (-10 V) TBI-2 yellow (-5...
Page 68
CHART 5-9 (CONT’D)INSTALL AN ANALOG BAY 3 KIT INTO AN SX-ZOO UNIVERSAL CABINET StepActionComments 18.install a surge clamp onto the Bay 3 backplaneat slot 16, pins 9 to 32; ensure that surge clamp is installed right side up (see label on clamp). 19.Install cables between Bay 3 and distribution frame. 20.Remove six screws that hold the rear cableRefer to Figure 5-6. panel to cabinet; install lower door supportonto cabinet and secure with IO-32 screws in eleventh hole from bottom, with the bracket above...
Page 69
Shipping, Receiving, and Installation InformationStepActionIComments 29. 30. 31. 32.Remove the old hinge brackets for the rear door from the cabinet frame. 33.Put on the antistatic wrist strap. 34. 35. 36. StepAction 1. 2. 3. 4. 5. 6.CHART 5-9 (CONT’D) INSTALL AN ANALOG BAY 3 KIT INTO AN SX-200 UNIVERSAL CABINET CAUTION: This upgrade and installation procedure is to be performed only by qualified per- Install rear door fan assembly and tighten two nuts on hinge bracket. Attach door ground wire from...
Page 70
SECTION MITLSI 09-094-200-NA, GREEN, MOUNTINGrSCREWS1 KAll014ElRFigure 5-3 Cardfile to Frame and Backplane Ground Connections Page 62