Page 91

Shipping, Receiving, and Installation Information
TABLE 5-l
MAINTENANCE PANEL RS-232 CONNECTOR PIN ASSIGNMENTSDTEDCERS-232RS-232data terminal equipment data communication equipment
pinsignal[local (dte) port]
[remote (dce) port]
2TRANSMIT DATAfrom terminalto modem
3RECEIVE DATAto terminalfrom modem
4REQUEST TO SENDfrom terminalto modem
5CLEAR TO SENDto terminal
6DATA SET READYto terminal
7SIGNAL GROUND
8CARRIER DETECTto terminalfrom modem
20DATA TERMINAL READYfrom terminalto modem
Notes:Remote (DCE)...

Page 92

SECTION MITLSI 09-094-200-NATERMINAL
REMOTE 
- DEDICATED, PUBLIC NETWORK
REMOTELV LOCATED
TERMINAL
REMOTE 
- DIAL-UP
TO DPABX VIA
CENTRAL OFFICE
~0 PAIRCROSSCONNECTFOR AUTO-ANSWER
MODEM.REMOTELV LOCATED
TERMINAL
NOTE: The Auto-Answer MODEM is
permanently connected to 
onelocal station circuit (extension).
7707ElRFigure 5-18 Maintenance Terminal Connections 
- SX-200 Cabinet
Page 86 

Page 93

Shipping, Receiving, and Installation Information
REMOTE - DEDICATED, PUBLIC NETWORK
REMOTELY LOCATED
TERMINAL
REMOTE 
- DIAL-UP
REMOTELY LOCATED
TERMINAL
CONNECTAUTO-ANSWER
MODEM.
NOTE: The Auto-Answer MODEM is
permanently connected to one
local station circuit (extension).TO DPABX VIA
CENTRAL OFFICE
MODEM
KAOl97EOROFigure 5-19 Maintenance Terminal Connections 
- SX-200 Universal Cabinet
Page 87 

Page 94

CHART 5-18
INSTALL ATTENDANT CONSOLE-ISECTION 
MITL9109-094-200-NAStepActionComments
1.Unpack console and place it in position atRefer to Figure 5-20.
Attendant workstation.
2.Connect headset (or handset) to its cord, andThe two jacks are in parallel;
plug cord into jack at side of console.either may be used.
3.Plug the console modular cord into the jack atJack is marked LINE PORT.
the back of the console and into its assigned
modular telephone jack.
4.At the distribution frame, cross connect theFor...

Page 95

Shipping, Receiving, and installation Information
I,PRE-FORMED/ FOAM
PACKAGING
SHIPPING
CARTON
7959EOROFigure 5-20 Unpacking Attendant Console
Page 89 

Page 96

SECTION MITL9109-094-200-NA
DPABX
CROSS
- y!I’IyMODULAR
JACK
25 PAIR
CONNECTORIZEDCABLE
xQUAD
STATION
WIRE
CONSOLEMODULAR
CORDCONSOLE MODULE
ON UNIVERSAL
CARDNOTE:USE ONLY 
MITEL CABLE
P/N 559900007 FOR THE
CONSOLE MODULAR CORD.
770BEZRlFigure 5-21 Console Installation
Page 90 

Page 97

Shipping, Receiving, and Installation Information
CHART 5-19
INSTALL SUPERCONSOLE 1000TM ATTENDANT CONSOLE
StepActionComments
1.Unpack console and place it in position at
Attendant workstation.
2.
3.C 
)nnect handset (or headset) to its cord, andThe two jacks are in parallel;
plug cord into jack at side of console.either may be used.
Plug the console modular cord into the LINE
PORT jack at the back of the console and into
its assigned modular telephone jack.
4.At the distribution frame, cross connect...

Page 98

SECTION MITL9109-094-200-NA
PAEXCROSS
-..--_CONNECT
FIELDMODULAR
JACK
25 PAIR
CONNECTORIZED
CABLE
xSTATION
WIRE(1 PAIR)
CONSOLE
MODULAR
CORDTO ONE CIRCUIT ON
A DIGITAL LINE CARD
NOTE:USE ONLY MITEL CABLE
P/N 559900007 FOR THE
CONSOLE MODULAR CORD.
KAO’IIOEOROFigure 5-22 Superconsole 1000 Attendant Console Installation
Page 92 

Page 99

Shipping, Receiving, and Installation Information
CHART 5-20
INSTALL UNIVERSAL CARD AND MODULESStepActionComments
1.While wearing the antistatic wrist strap, unpackFigure 5-23 shows a Universal
the universal card(s) and its modules.Card and Modules.
2.Inspect for loose or missing components, andComplete repair tag, repack, and
for damage.return any damaged or incorrect
items.
3.Insert the modules into their assigned locations,Total power rating per universal
press them until they snap into their...

Page 100

SECTION MITL9109-094-200-NATABLE 5-3
TIP 
8i RING ASSIGNMENTS
Module
Tl RlT2 R2T3 R3
TX
nc
Relay 1Relay 2
(subcircult 5) (subcircuit 6)
PA outputrelay contacts
TRI RR1El Ml
Note: The relays on the Receiver card are program-controlled (and are NOT
associated with the DTMF receivers). The relay on the MOH/Pager is
operated when the paging circuit is in use (primarily for controlling an
external amplifier). The system will indicate an alarm and ignore the
universal card if its total module power rating is...