Page 51
CHART 5-3 INSPECT EQUIPMENT Step 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. Action Comments Remove keys taped to top of cabinet. Unlock and open cabinet front door. Ensure that cabinet doors open and close easily. Tighten all shelf retaining screws. Make sure that all components within the cabinet are secure and undamaged. Verify cards received against invoices. DO NOT UNPACK PCB CARTONS OR REMOVE cards from their antistatic bags at this time. Visually...
Page 52
Shipping, Receiving, And installation information CHART 5-4 INSTALL CONTROL CABINET Note: Ideally, a Control cabinet is installed to the left of a Peripheral cabinet (existing SX-200@ cabinet if upgrading). The cabinets may be separated by up to the length of the PCM cable which connects them together. Step 1. 2. Action Place the Control cabinet into its assigned position. Ensure that the doors open freely, that there is adequate room for access, and that the AC receptacle and cross-connect...
Page 53
Shipping, Receiving, And Installation Information CHART 5-5 VERIFY GROUND CONNECTION Note: Before installation can begin a #6 AWG green ground wire must be connected between the equipment location and an approved ground (metallic cold water pipe or equivalent where it enters building). Step 1. Action Before plugging any cards into the cabinet, or connecting the Equipment Ground wire, ensure the equipment circuit breakers are turned off. Comments Do not power up the PABX. 2. Plug the AC...
Page 54
Shipping, Receiving, And Installation Information CHART 5-6 INSTALL PERIPHERAL CABINET Step 1. Action Unpack the cabinet and other items, except printed circuit cards. Check items received against packing list. Comments 2. Inspect the cabinet, shelf, and other items for Ensure that the doors open and loose, missing, or damaged parts. close freely, and all cables are secure and in place. Remove shipping screws from rear door. 3. Place the peripheral cabinet on the right side of the control...
Page 55
Shipping, Receiving, And Installation information CHART 5-7 INSTALL ANALOG BAY 3 KIT Step 1. Action Unpack kit and inspect contents for loose, damaged, or missing items. Comments 2. Open Control cabinet doors, set power switches to OFF, set main breaker on rear door to OFF, and remove line cord from wall outlet. 3. Remove rear door fan assembly - unplug fan supply cord, detach cord strain relief at stud - remove door ground wire at door stud - remove door 4. Remove rear door - unplug...
Page 56
Shipping, Receiving, And Installation Information CHART 5-7 (CONT’D) INSTALL ANALOG BAY 3 KIT Step 10. 11. Action Connect the wiring harness, 2”d D.C., (pn 103148501) between the Interconnect card and the PFT card. Interconnect Colour PFT TB301-1 Brown TB-3 TB30 1-2 Blue TB-5 TB30 1-3 TB30 l-4 White TB-6 ‘TB30 1-5 Red TB-7 TB30 1-6 Orange TB-4 TB30 1-7 Yellow TB-2 Install cutover monitor cable (pn 114905501) from P18 on Interconnect card to TB-7 on PFT card. Secure connector with a...
Page 57
Shipping, Receiving, And Installation Information EQIJJEy;NT POLVETHVLENE PACKING PIECES END SUPPORT KA0185ROEO Figure 5-2 Equipment Analog Shelf Packaging Page 5-l 1
Page 58
Shipping, Receiving, And Installation Information CHART 5-7 (CONT’D) INSTALL ANALOG BAY 3 KIT Step 18. Action Connect the DC power cable leads to the Bay 3 backplane, as shown in Figure 4-l 1. Comments 19. Connect the DC power cable to the Interconnect card as follows: TB301-1 brown TB301-2 blue TB301-3 braided gnd cable to Control shelf frame TB301-4 nc TB301-5 nc TB301-6 orange TB30 1-7 yellow 20. Connect connectors from Maintenance Panel cable to P301 and P303 of Interconnect Card....
Page 59
Shipping, Receiving, And installation information CHART 5-7 (CONT’D) INSTALL ANALOG BAY 3 KIT Step 27. Action Install upper support over power supply hinge pin and secure to cabinet with four screws and lockwashers. Comments 27. Connect ground lead to rear door power supply using hardware from original door. 29. Plug AC distribution unit assembly supply cord into the power supply outlet. Attach cable strain relief to power supply door by removing power supply cover screw and replacing it...
Page 60
Shipping, Receiving, And Installation Information CHART 5-8 INSTALL BAY 3 KIT INTO AN SX-200@ UNIVERSAL CABINET Step 1. Action Unpack kit contents and inspect for loose, damaged, or missing items. Comments 2. Open Control cabinet doors, set BPS switches to OFF, set main breaker on rear door to OFF, and remove line cord from wall outlet. 3. 4. 5. 6. Install Interconnect card with six screws on Top right mounting hole goes to the upper left side of the cabinet (viewed sixth hole from top of...