Page 21
Shipping, Receiving, And installation information DECRYPTION MODULE I r 7736ROEO Figure 2-7 Main Control Card and Decryption Module Page 2-12
Page 22
Shipping, Receiving, And Installation Information can be used for night bells, alarms, etc. Module power rating is 2. a Music/Paging Module - Provides one 600 ohm balanced audio (music) input and a 200 ohm output, to a paging amplifier. There is also one relay contact, which can be used for control- ling an amplifier. Module power rating is 1. 0 Console Module - Provides interface to certain Digital Line Interface Circuit-based peripheral devices. Each Attendant Con- sole requires a CONSOLE...
Page 23
Shipping, Receiving, And Installation Information 7685ROEO Figure 2-8 Digital Interface Card Page 2-14
Page 24
Shipping, Receiving, And installation Information Digital Peripheral Shelf 2.23 Bay Control Card. The Bay Control Card (BCC) is installed in the lower rightmost slot of digital Bays 3 and 4. This card monitors lines, trunks and other circuits within the bay. Maintenance Panels 2.24 Control Cabinet. The maintenance panel is located at the top front of the control cabinet, behind the door, and contains the following controls and connections for the PABX: Top Shelf Power - controls bay 3 power...
Page 25
Shipping, Receiving, And Installation Information PFT Switches - control source of power fail transfer initiation. Default Hardware Assignments 2.27 The following hardware equipment assignments are pro- grammed into the default database; it is recommended that these default assignments be followed when first configuring or in- stalling a system. test line (terminal and jack) Bay 2, Slot 1, Circuit 1 (requires ONS Line card at Bay 2, Slot 1) maintenance panel console jack bay 2, slot 3,...
Page 26
Shipping, Receiving, And Installation Information hook, and dial the required number. With a loop start trunk, go off-hook and dial the required number. Since the telephones are connected directly to the CO, usual PABX access codes are not dialed. Relays 2.30 Two relays are provided on the receiver module, which can be operated under control of the program, to control various sys- tem functions, such as night bells or alarms. relay contact ratings 90 Vrms at 0.1 A 48 Vdc at 0.5 A Note: This...
Page 27
Shipping, Receiving, And Installation Information Output Waveform Sinewave or Quasi square wave (not square wave) Output Receptacle NEMA 15 A 3-pin grounded Holdup/Recharge Times Per customer requirements. Several recommended manufacturers of Uninterruptible Power Sup- plies has provided samples of their equipment which have proved to be compatible with an SX-200a DIGITAL PABX in laboratory tests. Please note that compliance to electrical installation and building codes is the responsibility...
Page 28
Shipping, Receiving, And installation Information E&M Trunk Module 2.37 The E&M Trunk Module plugs into the Universal Card. It pro- vides interface to Types 1 or 5 E&M trunks. The module has a power consumption category of 3. Because of this, only three of these modules can be used per Universal Card. 2.38 The E&M Trunk Module is set for the type of trunk in use by setting its eight DIL switches. 2.39 0 Facilities provided by the E&M Trunk Module include: selectable Type 1 or Type 5 signaling...
Page 29
Shipping, Receiving, And installation information 3. INSTALLATION REQUIREMENTS Environmental Requirements 3.01 The SX-ZOO@ DIGITAL PABX equipment maybe installed in any location which fulfills the space requirements as detailed in paragraph 3.02, and is within the following temperature and humidity ranges: l Temperature +I0 to +4O”C (+50 to +104”F) 0 Relative Humidity 20-80% (non-condensing) 0 Maximum Altitude 4000 meters. Floor Space 3.02 The minimum floor space for installation and...
Page 30
Shipping, Receiving, And Installation Information 0 Near a reproducing or copying machine. A minimum clearance of 3 m (10 It) must be provided if the reproducing machine is not equipped with a filtering system, and the room should be ventilated by an exhaust fan. Power Supply Requirements 3.04 The customer must provide one single-phase power receptacle for each cabinet, as follows: 0 Each cabinet should have its own 120 V, 60 Hz, 15 A branch circuit. 0 The power receptacle must be a 3-wire...