System Test Procedures 
CHART 2-9 (CONT’D) 
SYSTEM LEVEL: DATABASE COPYING 
Step Action Verify 
8 Insert a disk containing 
system software but no 
Customer Data, then go to 
Step 9. 
OR 
Go to Step 9. 
9 Press 0 (CONTINUE Command line displays message: 
softkey). Writing database, please wait . . . 
System copies Customer Data to disk. When copy is 
complete, command line responds with: 
Copy successful. If upgrading then RESET - else press 
CANCEL to continue. 
10 Press 5 (CANCEL softkey). Softkey...

Page 412

System Test Procedures 
MONITOR Command 
2.12 The MONITOR command (accessed from the System Level 
functions of the Maintenance Terminal) allows the user to mon- 
itor the progress of system diagnostics as they are run, of main- 
tenance logs as they occur, and of SMDR reports as they occur. For 
further information regarding these, refer to Section 
MITL9108-093-351-NA, RS-232 Maintenance Terminal. Chart 2-10 
shows the steps for testing the MONITOR command. 
CHART 2-10 
SYSTEM LEVEL: MONITOR COMMAND...

Page 413

System Test Procedures 
STOP Command 
2.13 
The STOP command (accessed from the System Level) allows 
the user to stop the system monitoring of logs. For information 
regarding monitoring of logs, refer to MITL9108-093-351-NA, RS-232 
Maintenance Terminal. Chart 2-11 shows the steps for testing the 
STOP command. 
CHART 2-11 
SYSTEM LEVEL: STOP COMMAND 
Step Action Verify 
1 
Access MAINTENANCE System responds by displaying Maintenance menu. 
application. 
2 Press 1 (SYSTEM softkey). Softkey prompts...

Page 414

System Test Procedures 
Diagnostics 
2.14 The Diagnostics Level (accessed from the Maintenance menu) 
allows the user to enable, schedule, and initiate system di- 
agnostic testing, take equipment out of service, and return it to ser- 
vice. For further information regarding these, refer to Section 
MITL9108-093-351-NA, RS-232 Maintenance Terminal. Charts 2-12 
through 2-16 show the steps for testing the Diagnostics Level com- 
mands. 
CHART 2-12 
DIAGNOSTICS LEVEL: TEST COMMAND 
Step Action Verify 
1...

Page 415

System Test Procedures 
CHART 2-12 (CONT’D) 
DIAGNOSTICS LEVEL: TEST COMMAND 
Step Action Verify 
9 
Press 0 (ENTER softkey). Command line clears, and the test command is displayed 
in the display area. If no cards are present in the Bay 
tested, no other action is seen, and softkey prompts 
return to the diagnostics level format. If an analog Bay is 
tested, the message: 
This function is not available for this device. 
appears and CANCEL softkey prompt is displayed. If a 
Bay/Slot/Circuit location is...

Page 416

System Test Procedures 
CHART 2-12 (CONT’D) 
DIAGNOSTICS LEVEL: TEST COMMAND 
Step Action Verify 
13 Repeat Steps 10 through 
12 for remaining device 
types. 
14 Press 1 (TEST softkey). Command line responds with: 
TEST 
and softkey prompts change. 
15 Press 3 (EXT-NUM softkey). Command line responds with: 
TEST EXT-NUM enter Ext. Number then press RETURN: 
and no softkey prompts are displayed. 
16 Enter an extension number, Command line clears, and a test message appears in the 
press RETURN (if...

Page 417

System lest Procedures 
CHART 2-13 
DIAGNOSTICS LEVEL: SHOW COMMAND 
Step Action Verify 
1 Access MAINTENANCE System responds by displaying Maintenance menu. 
application. 
2 Press 3 (DIAGNOSTICS Softkey prompts change. Diagnostics Level is accessed. 
softkey). 
3 Press 2 (SHOW softkey). Command line responds with: 
SHOW 
and softkey prompts change. 
4 Press 7 (SSET-ERRORS Command line responds with: 
softkey). SHOW SSET-ERRORS 
5 Press 0 (ENTER softkey). A summary of SUPERSET qTM set errors by physical...

Page 418

System Test Procedures 
CLEAR Command 
2.15 
The CLEAR command is the complementary command to the 
Diagnostics Level SHOW SSET-ERRORS command. Selecting 
this command results in prompts to clear SUPERSET qTM set errors by 
location (bay/slot/circuit) or extension number, or simply to clear all 
SUPERSET qTM set errors. Chart 2-14 shows the steps for testing the 
Diagnostics Level CLEAR command. 
CHART 2-14 
DIAGNOSTICS LEVEL: CLEAR COMMAND 
Step Action Verify 
1 Access MAINTENANCE System responds by...

Page 419

System Test Procedures 
Accessing Enabling and Disabling of Diagnostic Functions 
2.16 The MORE-KEYS command is used in the Diagnostics Level to 
access the enabling and disabling of diagnostics functions 
(either Power-up or Background diagnostics), removing equipment 
from service, or returning equipment to service. When the Diagnostics 
Level softkeys are displayed, press 0 (MORE-KEYS) to access these 
functions. Chart 2-15 shows the steps for testing enabling and dis- 
abling of diagnostic functions....

Page 420

System Test Procedures 
CHART 2-15 (CONT’D) 
DIAGNOSTICS LEVEL: ENABLING AND DISABLING DIAGNOSTICS 
Step Action Verify 
8 Press 7 (DISABLE-DIAG Command line responds with: 
softkey). DISABLE-DIAG 
and softkey prompts change. 
9 Press 1 (BACKGROUND Command line responds with: 
softkey. DISABLE-DIAG BACKGROUND 
and softkeys change, as in Step 5. 
IO Repeat Steps 6 and 7. Background Diagnostics disable message appears in 
display area. The selected diagnostics are disabled. 
Softkey prompts return to...