Customer Data Entry (CDE) 
4.101 Commands 
l-READ ONLY Pressing the READ ONLY softkey restricts the user to 
viewing the selected form; no modifications can occur. The R prompt 
appears beside the selected form and under the selected access level. 
2-READ/WRITE Pressing the READ/WRITE softkey enables the user to 
view and modify the selected form. The form displays the R/W prompt 
to indicate this state. 
3-NO ACCESS Pressing the NO ACCESS softkey restricts form access. 
The form displays the none prompt...

Page 362

Customer Data Entry (CDE) 
1 -INSTALLER 2-MAINTI 
6- 7- 3-MAINT2 
8- 4-SUPERVISOR 
9- 5-ATTENDANT 
O- 
FIGURE 4-14 LEVELS OF ACCESS 
Page 4-l 16  

Page 363

Customer Data Entry (CDE) 
Form 29 - Device Interconnection Table 
4.102 This form specifies which devices may be connected together. 
Refer to Table 4-39, Device Interconnection Table. The system 
allows for a maximum of 25 devices. 
4.103 Field Description. Initially, the system interconnects all de- 
vices. The asterisk (*) character indicates this condition. When 
the system inhibits device interconnection, it is indicated by the period 
(.) character. The device numbers are listed in the header line...

Page 364

Customer Data Entry (CDE) 
TABLE 4-39 
FORM 29 - 
DEVICE INTERCONNECTION TABLE 
COE TERMINAL DISPLAY 
4:26 l-JAN-86 alarm status = NO ALARM 
01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 
01************************t 
02************************* 
03****************f******** 
04************************* 
05************************* 
m************************* 
07************************* 
08*******t******i*********t qg************************* 
10****+********************...

Page 365

Customer Data Entsy (CDE) 
4.104 Commands 
4-TOP Pressing the TOP softkey moves the line pointer to the first 
line of the form. The command line displays the first line. 
5-BOTTOM Pressing the BOTTOM softkey moves the line pointer to 
the last line of the form. The command line displays this line. 
6-QUIT Pressing the QUIT softkey when editing this form displays the 
following warning on the command line: DATA HAS BEEN CHANGED 
BUT NOT YET SAVED -- “ENTER” TO SAVE. Pressing this softkey 
again exits...

Page 366

Customer Data Entry (CDE) 
Review List for Form 29 
4.105 This form appears when the REVIEW softkey is pressed in De- 
vice Interconnection Table Form. When entered from Form 29, 
this form displays a list of the device types. Refer to Table 4-40, 
Review List for Form 29 for the form layout. Note that the data in this 
form cannot be modified. 
4.106 Field Description 
ENTRY NUM Field This field lists the entry numbers for the device 
types. There is a total of 25 entry numbers. The ENTRY NUM field...

Page 367

Customer Data Entry (CDE) 
TABLE 4-40 
REVIEW LIST FOR FORM 29 
CDE TERMINAL DISPLAY 
4:26 1 -JAN-86 
alarm status = NO ALARM 
ENTRY NUM DEVICE TYPE DESCRIPTION INTERCONNECT NLJM 
01 Stat ion/Set I 
02 Cons01 e 2 
03 Loop Start Trunk 3 
04 Ground Start Trunk 4 
05 DID/Tie Trunk 5 
06 2-Wi re E&M 6 
07 4-Wire Unamplified E&M 7 
08 4-Wire Amp1 if led E&M 8 
09 RESERVED 
9 
10 RESERVED 
10 
11 RESERVED 
11 
12 RESERVED 12 
01 Station/Set 
1 
l- 2-ENTRY NUM 3- 
4-TOP 5-BOTTOM 
B-QUIT 7-INTERCON NUM 8- 9- 
O-...

Page 368

Customer Data Entry (CDE) 
4.107 Commands 
2-ENTRY NUM This softkey selects an entry number. Pressing the 
ENTRY NUM softkey displays the ENTER ENTRY NUM: on the com- 
mand line. The selection is completed by entering a valid entry number 
(1 to 25). 
4-TOP Pressing the TOP softkey moves the line pointer to the first 
line of the form. The command line displays the first line. 
5-BOTTOM Pressing the BOTTOM softkey moves the line pointer to 
the last line of the form. The command line displays this line....

Page 369

Customer Data Entry (CDE) 
Form 30 - System Abbreviated Dial Entry 
4.108 This form specifies the index Number, the digit strings for each 
Index Number and the status of that Index Number (Private or 
Non-Private). Refer to Table 4-41, Form 30 - System Abbreviated Dial 
Entry for the form layout. Refer to Section MiTL9108-093-223-NA, 
Abbreviated Dialing for details. 
4.109 Field Description 
INDEX NUMBER Field 
This field lists the index numbers; one for each 
entry in the DIGIT STRING field. The Index...

Page 370

Customer Data Entry (CDE) 
4 I : 26 1 -JAN-86 alarm status = NO ALARM 
TABLE 4-41 
FORM 30 - SYSTEM ABBREVIATED DIAL ENTRY 
CDE TERMINAL DISPLAY 
INDEX NUMBER 
22 
123 
77 DIGIT STRING 
8367965 
5922 122 
2240667 PRIVATE 
PRIVATE 
PRIVATE 
i23 5922 122 I 
l- 2-FIND INDEX 3- 4-TOP 5-BOTTOM 
6-QUIT 7- 8- g-PRIVATE O- 
ATTENDANT CONSOLE DISPLAY 
INDEX NUMBER DIGIT STRING 
123 5922 122 
Fl> 
F2>FIND INDEX F3> 
FG>QUIT F7> 
F8> PRIVATE 
F4>TOP F5>BOTTOM 
FSSPRIVATE FO> 