Home > Mitel > Communications System > Mitel SX-200 DIGITAL Pabx Information Manual

Mitel SX-200 DIGITAL Pabx Information Manual

Here you can view all the pages of manual Mitel SX-200 DIGITAL Pabx Information Manual. The Mitel manuals for Communications System are available online for free. You can easily download all the documents as PDF.

Page 321

Customer Data Entry (CDE) 
Form 17 - Hunt Groups 
4.66 This form specifies the members of each Hunt Group by exten- 
sion numbers. Refer to Table 4-25, Hunt Groups. The system 
supports a maximum of 50 Hunt Groups; each group supports a maxi- 
mum of 50 members. 
4.67 
Field Description. The header line indicates which Hunt Group 
is being programmed and whether it is a Terminal or Circular 
Hunt Group. 
EXT NUM Field This field lists the members of each Hunt Group 
according to their extension numbers....

Page 322

Customer Data Entry (CDE) 
----TABLE 4-25 
/ 
j: y--$ij& 17 
- HLJNT GROUPS 
1 
CDE TERMINAL DISPLAY 
4:26 
1 -JUN-86 alarm status = NO ALARM 
[GRP I:7798 I CCIRCl[STN/SET] EXT NUM BAY 
SLT CCT COMMENTS 
Ill 01 03 01 M. SMITH 
112 01 03 02 G. BROWN 
113 01 03 03 L. GREENE 
114 01 03 04 J. HENRY 
l-GROUP TYPE 
6-QUIT 111 01 03 01 M. SMITH 
2-TERMINAL 3-INSERT 4- 
5-HUNT GROUP 
7-ACCESS CODE 8-DELETE S- O- 
ATTENDANT CONSOLE DISPLAY 
[GRP 1: 7798 I CCIRCI[~TN/SET~ EXT NUM BAY 
SLT CCT COMMENTS 
Ill 01 03...

Page 323

Customer Data Entry (CDE) 
4.68 Commands 
l-GROUP TYPE Pressing this softkey displays three new softkeys 
which represent three Hunt Group types. Softkeys GROUP TYPE and 
CIRCULAR/TERMINAL do not appear until the hunt group exists. A hunt 
group is not created until the first member is defined. Refer to Figure 
4-12, Hunt Group Types. Note that the selected group type does not 
appear on the softkey display. 
1 -STN/SET 2-RECORDING 3-AGENT 4- 5- 
B-QUIT 7- 8- S- o- 
FIGURE 4-12 HUNT GROUP TYPES...

Page 324

Customer Data Entry (CDE) 
saved. At all other times, pressing this softkey exits Form 17 and 
returns the display to the level where the forms are selected. Refer to 
Table 4-2, Available Forms. 
6-CANCEL This softkey appears after a programming error has oc- 
curred. Pressing the CANCEL softkey returns the display to the level 
where the programming error was made. The CANCEL softkey appears 
with an error message. Refer to Table 4-45, Programming Error Mes- 
sages for a list of these error messages....

Page 325

Customer Data Entry (CDE) 
Form 18 - Miscellaneous System Ports 
4.69 
This form assigns a physical identification location to three 
types of devices and three alarms. The devices are a Music on 
Hold source, Paging equipment and Night Bells equipment. The alarms 
are Minor, Major and Critical. The system supports 25 night bells, nine 
paging zones and one Music on Hold source. Refer to Table 4-26, Entry 
Number Designations and Table 4-27, Miscellaneous System Ports for 
the form layout. 
4.70 Field...

Page 326

Customer Data Entry (CDE) 
TABLE 4-26 
ENTRY NUMBER DESIGNATIONS 
Entry Number Title 
01 
Music on Hold 
02 Pager 1 
03 Pager 2 
04 Pager 3 
05 Pager 4 
06 Pager 5 
07 Pager 6 
08 Pager 7 
09 Pager 8 
IO Pager 9 
11 Minor Alarm 
12 Major Alarm 
13 Critical Alarm 
14 Night Bell 1 
15 Night Bell 2 
16 Night Bell 3 
17 Night Bell 4 
18 Night Bell 5 
19 Night Bell 6 
20 Night Bell 7 
21 Night Bell 8 
22 Night Bell 9 
23 Night Bell 10 
24 Night Bell 11 
25 Night Bell 12 
26 Night Bell 13 
27 Night Bell 14 
28...

Page 327

Customer Data Entry (CDE) 
SUBClRCUlT 6 
K-2 
SUBCIRCUIT 5 
IKl) 
RECEIVEWRELAV 
MODULE 
LEDs 
1 - MODULE 1 
I 
-i-- MODULE 2 
rT MODULE 3 
CW MODULE 4 
-i- ALARM 
Figure 4-13 Universal Card Circuits and Subcircuits 
Page 4-81  

Page 328

Customer Data Entry (CDE) 
:26 I -JUN-86 alarm status = NO ALAR 
TABLE 4-27 
FORM 18 - 
( .- MISCELLANEOUS SYSTEM PORTS 
CDE TERMINAL DISPLAY 
ENTRY NUMBER 
01 Music on Hold 
02 Pager 1 
03 Pager 2 
04 Pager 3 
05 Pager 4 
06 Pager 5 
07 Pager 6 
08 Pager 7 
09 Pager 8 
IO Pager 9 
11 Minor Alarm 
12 Major Alarm 
01 
I- Music 
on Hold 
1 I 
12- 
DESCRIPTION 
P- 
BAY 
02 
02 
02 
- 
SLT 1 CCT 
03 01 
03 01 
04 1 03 SCT 
01 
02 EXTENSION NUMBER 
02 
I 
I 4-TOP 
1 5-BOTTOM 
i+QUIT 7-ENTRY NUM a-DELETE 9- O-...

Page 329

Customer Data Entry (CDE) 
4.71 Commands 
4-TOP Pressing the TOP softkey moves the line pointer to the first 
line of the form. The command line displays the first line. 
5-BOTTOM Pressing the BOTTOM softkey moves the line pointer to 
the last line of the form. The command line displays this line. 
5-QUIT Pressing the QUIT softkey when editing this form returns the 
display to the level before the field was modified. The change is not 
saved. At all other times, pressing this softkey exits Form 18 and...

Page 330

Customer Data Entry (CDE) 
Form 19 - Call Rerouting Table 
4.72 This form designates where intercepted and attendant-directed 
calls will route based on Day Service, Night1 Service and Night2 
Service. Refer to Table 4-28, Call Rerouting Options. Refer also to 
Table 4-29, Call Rerouting Table for the form layout. Each Tenant 
Group requires a Call Rerouting Table. “DIAL 0” calls can be directed to 
an LDN, Rotary Dial or DTMF set, SUPERSET@ set or Night Bell exten- 
sion number, or to an individual...