Page 311

Customer’ Data Entry (CDE) 
d) Form 09 for SUPERSET@ set line appearance programming (DTS 
or Private Trunk) and 
e) Form 16 for listing members of Trunk Groups. 
BLF Field This field is reserved for future use. 
COMMENTS Field This field is reserved for additional data (a maxi- 
mum of 15 characters). It is stored by the system but not used. 
Page 4-65  

Page 312

Customer Data Entry (CDE) 
TABLE 4-22 
,.--  F2> 
FB>TRUNK NUMBER F4> F5> 
FGHXJIT 
F7>BAY/SLT/CCT F8>DELETE F9> FO> 
Page 4-66  

Page 313

Customer Data Entry (CDE) 
4.59 Commands 
3-TRUNK NUMBER This softkey selects a trunk by its trunk number. 
Trunk numbers are assigned in Form 14 (Table 4-22, Non-Dial-in 
Trunks) and Form ‘I5 (Table 4-23, Dial-In Trunks). Pressing the TRUNK 
NUMBER softkey displays the ENTER TRUNK NUM: prompt on the 
command line. Entering a valid trunk number (1 to 200) selects that 
Non-Dial-In Trunk and displays it on the command line. 
6-QUIT Pressing the QUIT softkey after a field has been edited re- 
stores the...

Page 314

Customer Data Entry (CDE) 
Form 15 - Dial-h Trunks 
4.60 This form specifies the characteristics of the system’s Dial-in 
Trunks. This form also designates where incoming calls on 
Dial-In Trunks are routed by modifying the incoming digits. Refer to 
Table 4-23, Dial-in Trunks for form layout. 
4.61 Field Description 
BAY, SLT and CCT Fields 
These fields list the physical location 
identification of each Dial-In Trunk. They are generated by the system 
based on what was entered in the PROGRAMMED field...

Page 315

Customer Data Entry (CDE) 
c) attendant Direct Trunk Select (DTS) capability, 
d) 
Form 09 for SUPERSET@ set line appearance programming (DTS 
or Private Trunk) and 
e) 
Form 16 for listing members of Trunk Groups. 
BLF Field This field is reserved for future use. 
COMMENTS Field This field is reserved for additional data (a maxi- 
mum of 15 characters). It is stored by the system but not used. 
Page 4-69  

Page 316

Customer Data Entry (CDE) 
TABLE 4-23 
FORM 15 - 
DIAL-IN TRUNKS 
CDE TERMINAL DISPLAY 
4 : 26 1 -JUN-86 alarm status = NO ALARM 
BAY SLT CCT COS COR 
TEN N M X CDN 
TK NUM BLF ’ COMMENiS 
2 02 03 1 I I 0 0 2 1 
2 02 04 
2 02 05 
2 02 06 
2 06 03 
3 06 04 
3 07 01 I 1 1 oi 0 16 27 ” 
3 07 02 1 1 I 0 0 16 28 
3 08 01 1 I 1 0 0 16 29 
3 08 02 I 1 1 0 0 16 30 
4 06 03 
4 06 04 
2 02 03 I I 1 010 2 1 
l- 2- 3-TRUNK NUMBER 4- 5- 
6-QUIT 7-BAY/jLT/CCT 8-DELETE 9- 
O- 
ATTENDANT CONSOLE DISPLAY 
BAY SLT CCT COS...

Page 317

Customer Data Entry (CDE) 
4.62 Commands 
3-TRUNK NUMBER This softkey selects a trunk by its trunk number. 
Pressing the TRUNK NUMBER softkey displays the ENTER TRUNK 
NUM: prompt on the command line. Entering a valid trunk number (1 
to 200) selects that Dial-In Trunk and displays it on the command line. 
6-QUIT Pressing the QUIT softkey directly after a field has been 
modified restores the form to the level before the field was edited. The 
change is not saved. At all other times, pressing this...

Page 318

Customer Data Entry (CDE) 
Form 16 - Trunk Groups 
4.63 This form specifies the members of each Trunk Group by trunk 
numbers. The trunk number is assigned in Form 14 (refer to 
Table 4-22, Non-Dial-In Trunks) and Form 15 (refer to Table 4-23, 
Dial-In Trunks). The system supports a maximum of 50 Trunk Groups; 
each group supports a maximum of 50 members. Refer to Table 4-24, 
Trunk Groups for the form layout. 
4.64 Field Description. The header line indicates the Trunk Group 
being programmed, via a...

Page 319

Customer Data Entry (CDE) 
TABLE 4-24 
i- 
FORM ‘I6 - TRUNK GROUPS 
CDE TERMINAL DISPLAY 
4:26 1 -JUN-86 
alarm status = NO ALARM 
[GRP: i-TORONTO ] [NO SMDR][fERM] TK NUM BAY SLT CCT COMMENTS 
1 03 09 01 
2 03 IO 01 
1 03 09 01 
1 -SMDR 2-CIRCULAR 3-INSERT 4-TK GRP NAME 5-TRUNK GROUP 
3-QUIT 7- 8-DELETE 9- O- 
ATTENDANT CONSOLE DISPLAY 
[GRP: i-TORONTO ] [NO SMDR][TERM] TK NUM BAY 
SLT CCT COMMENTS 
1 03 09 01 
Fl>SMDR 
F22CIRCULAR F3>INSERT F42TK GRP NAME FB>TRUNK GROUP 
FG>QUIT F7> 
F8>DELETE F9> 
FO>...

Page 320

Customer Data Entry (CDE) 
4.65 Commands 
l-SMDR/NO SMDR This softkey has two functions. It enables and 
disables the Station Message Detail Recording (SMDR) feature for each 
Trunk Group. When the SMDR feature is enabled, the header line 
displays [SMDR 
1 and the softkey displays NO SMDR. Pressing the 
NO SMDR softkey disables the SMDR feature for that Trunk Group. The 
softkey now displays SMDR and the header line displays [NO SMDRI. 
P-CIRCULAR/TERMINAL This softkey has two functions. It specifies...