Customer Data Entry (CDE) 
Form 03 - COS Define 
4.17 This form defines the Classes of Services for the system (refer 
to Table 4-7, COS Define for the form layout). Classes of Ser- 
vice group together stations with common feature operations and 
restrictions. The SX-200@ DIGITAL PABX with Generic 1001 software 
accommodates a maximum of 50 Classes of Service. Each device 
(including attendants and all trunks) are supplied with a Class of Ser- 
vice. This provides for the multi-attendant environment...

Page 262

Customer Data Entry (CDE) 
TABLE 4-6 (CONT’D) 
CLASS-OF-SERVICE OPTIONS 
STATION/SUPERSET@-RELATED 
Option Number Class-of-Service Name 
203 Broker’s Call 
204 Call Block Applies (Room To Room) 
205 Call Distribution Agent Position 
206 Call Forwarding - Busy 
207 Call Forwarding - Don’t Answer 
208 Call Forwarding - External 
209 Call Forwarding - Follow Me 
210 Call Forwarding Inhibit on Dial-In Trunks 
211 Call Hold and Retrieve Access 
212 Can Flash if Talking to an Incoming Trunk 
213 Can Flash if...

Page 263

Customer Data Entry (CDE) 
TABLE 4-6 (CONT’D) 
CLASS-OF-SERVICE OPTIONS 
STATION/SUPERSET@-RELATED 
Option Number Class-of-Service Name 
250 Transfer With Privacy 
251 Call Forward - Don’t Answer Timer (2 - 6 Rings) 
Default is 3 Rings 
252 Call Hold Recall Timer (1 - 5 Minutes) 
Default is 1 Minute 
253 Repeated Camp-on Beeps Timer (5 - 45 Seconds) 
Default is 10 Seconds 
254 UCD Music on Hold Timer (0 - 50 Minutes) 
ATTENDANT/STATION/SUPERSET@-RELATED 
Option Number Class-of-Service Name 
300 Automatic...

Page 264

Customer Data Entry (CDE) 
TABLE 4-6 (CONT’D) 
CLASS-OF-SERVICE OPTIONS 
SUPERSET@-RELATED 
Option Number Class-of-Service Name 
602 SUPERSET@ - Background Music 
603 SUPERSET@ - Disconnect Alarm 
604 SUPERSET@ - immediate Line Select 
605 SUPERSET@ - Message Program 
606 SUPERSET@ - Sub-Attendant 
607 SUPERSET@ - Associated Modem Line 
608 SUPERSET@ - Room Status Display: . 
609 SUPERSET@ - Night Service Switching 
ALL DEVICES 
Option Number Class-of-Service Name 
700 SMDR - Does Not Apply 
701 No Dial...

Page 265

Customer Data Entry (CDE) 
____ ..~ ~- 
( TABLE 4-7 
/ 
/ FORM 03 - CDS DEFINE 
CDE TERMINAL DISPLAY 
: 26 1 -&N-86 
alarm status = NO ALARM 
[ cos : I I OPTION NAME (DISPLAYING ENABLED > 
Attendant Bell-Off STATUS OPTION NUM 
Attendant Display of System Alarms 
Attendant DISA Code Setup 
Attendant Flexible Night Service Setup 
Attendant New Call Tone 
Attendant Automatic Call Forward - No Answer 
Attendant Sertal Call 
Attendant Abbr. 
Dial Confidential Number Display 
Attendant Abbreviated Dial...

Page 266

Customer Data Entry (CDE) 
4.18 Field Description. The header line indicates the Class of Ser- 
vice being programmed and which set of options are selected; 
either the enabled or disabled options. The command line displays the 
current indexed option. When Form 03 - COS Define is selected, the 
command line displays the first enabled option of the first Class of 
Service. 
OPTION NAME Field This field lists the option titles. The actual option 
names cannot be modified. The option names are classified...

Page 267

Customer Data Entry (CDE) 
6-QUIT Pressing the QUIT softkey after a field has been edited re- 
stores the form to the level before the field was modified. The change 
is not saved. At all other times, pressing this softkey exits Form 03 and 
returns the display to the level where the forms are selected. Refer to 
Table 4-2, Available Forms. 
B-CANCEL This softkey appears after a programming error has oc- 
curred. Pressing the CANCEL softkey returns the display to the level 
where the programming error...

Page 268

Customer Data Entry (CDE) 
Form 04 - System Options/System Timers 
4.20 This form specifies the system’s options and timers that are 
systemwide. Refer to Table 4-8, System Options and Timers for 
the complete list and refer to Table 4-9, System Options/System Tim- 
ers for the form layout. 
TABLE 4-8 
SYSTEM OPTIONS AND TIMERS 
Option Number System Options/System Timers 
01 24 Hour Clock 
02 RESERVED 
03 RESERVED 
04 Message Waiting and Message Register Change Print 
05 Verified Account Codes 
06...

Page 269

Customer Data Entry (CDE) 
TABLE 4-8 (CONT’D) 
SYSTEM OPTIONS AND TIMERS 
Option Number System Options/System 
Timers 
42 Maximum Flash Timer (10 ms units) 20 - 150 
43 DISA Answer Timer (1 - 8 Seconds) 
44 Account Code Length (VARIABLE or 4 - 12 digits) 
45 Auto Room Status Conversion/Auto Wake-up Print Timer 
46 Room Status Call Restriction Default 
Page 4-23  

Page 270

Customer Data Entry (CDE) 
[.-v TABLE 4-B 
i.. FORM 04 - 
SYSTEM OPTIONS/SYSTEM TIMERS. 
CDE TERMINAL DISPLAY 
4:26 1 -JUN-86 alarm status = NO ALARM 
System Options (Displaying ENABLED Options) 
STATUS OPTION NUM 
Discriminating Ringing 
ENABLED 17 
Holiday Messages 
ENABLED 
20 
Incoming to Outgoing Call Forward 
ENABLED 21 
SUPEKSET Set Last Number 
Kedial ENABLED 29 
Digit Translation Plan o-3 I 35 
ARS Unknown Digit Length Time-out 
2-15 seconds 5 36 
Limited Wait For Dial Tone 
3-15 seconds 5 37...