Page 301
Customer Data Entry (CDE) 6-QUIT Pressing the QUIT softkey when editing this form returns the display to the level before the field was modified. The change is not saved. At all other times, pressing this softkey exits Form 13 and returns the display to the level where the forms are selected. Refer to Table 4-2, Available Forms. 6-CANCEL This softkey appears after a programming error has oc- curred. Pressing the CANCEL softkey returns the display to the level where the programming error occurred....
Page 302
Customer Data Entry (CDE) Review List for Form 13 4.51 This form appears when the REVIEW softkey is pressed in Form 13 - Trunk Circuit Descriptors. The form lists the trunks that use the selected trunk circuit descriptor. Refer to Table 4-19, Review List for Form 13 for the form layout. Note that the data in this form cannot be modified. 4.52 Field Description. The header line displays the descriptor number and the trunk type. TRK NUM Field This field lists the trunk numbers assigned to the...
Page 303
Customer Data Entry (CDE) CDE TERMINAL DISPLAY 4:26 I -JtJN-86 alarm status = NO ALARM [ 6CCTCOTRUNK: 21 TRK NUM BAY SLT CCT COMMENTS l- 2- 3- 2 9 IO 11 12 13 14 15 16 17 18 19 2 1 3 3 3 3 3 3 4 4 4 4 4 1 I 5 5 5 5 5 6 6 5 5 5 5 6 5 14- I 5- * +QUIT ‘I-DESC NUMBER 8- S- O- 2 1 2 3 4 1 2 I 2 3 4 1 I 2 I ATTENDANT CONSOLE DISPLAY [ 6CCTCOTRUNK: 2 ] TRK NUM BAY SLT CCT COMMENTS 2 1 5 2 Fl> F2> F3, F4> F5> F6=-QUIT F7>DESC NUMBER F8> F9> FO>...
Page 304
Customer Data Entry (CDE) 4.53 Commands 6-QUIT Pressing the QUIT softkey returns the display to the point where the REVIEW softkey was pressed. 6-CANCEL This softkey appears after a programming error has oc- curred. Pressing the CANCEL softkey returns the display to the level where the programming error occurred. The CANCEL softkey appears with an error message. Refer to Table 4-45, Programming Error Mes- sages for a list of these error messages. ‘I-DESC NUMBER This softkey selects ‘a t$unk...
Page 305
Customer Data Entry (CDE) Options for Trunk Circuit Descriptors 4.54 This form appears only when the SEL. OPTIONS softkey is pressed (refer to Table 4-18, Trunk Circuit Descriptors). This form displays the options (parameters) associated with each trunk type assigned to each trunk circuit descriptor. Refer to Table 4-21, Trunk Circuit Descriptor Options. 4.55 Field Description. The header line displays the trunk type, the trunk circuit descriptor number and the type of parameter under...
Page 306
Customer Data Entry (CDE) TABLE 4-20 (CONT’D) TRUNK HARDWARE OPTIONS bunk Type: 6-CIRCUIT CO and B-CIRCUIT DISA (cont’d) Supervision Direction: incoming Trunk Calls Also Guard Timer (0 - 3000 ms) x (100 ms increments) Ring Cycle Timer (6 - 10 s) x (1 s increments) Ignore Line Reversal During Seizure Ringing Expected Ringing Debounce Timer (5 - 12 s) x (1 s increments) Seize Timer (10 - 60 s) x (10 s increments) Flash Timer (200 - -700 ms) x (100 ms increments) Interdigit Timer (300 - 800 ms)...
Page 307
Customer Data Entry (CDE) TABLE 4-20 (CONT’D) TRUNK HARDWARE OPTIONS Trunk Type: E&M CARD (Cont’d) roll Office Is this a CO DTMF Impedance (600 Ohms or Complex) Remote End is a Satellite Remote End is a Satellite with OPS Lines Dictation Trunk .I ._ ..: , ! . . Twe: P-CCT DID/TIE Far-End Gives Answer Supervision Inhibit Automatic Supervision No Seize Alarm No Release Alarm Toll Office Is this a CO DTMF Impedance (600 Ohms or Complex) Remote End is a Satellite Remote End is a...
Page 308
Customer Data Entry (CDE) ____~.- -- ~- TABLE 4-21 ,_ FORM 13 - TRUNK CIRCUIT DESCRIPTOR OPTIONS CDE TERMINAL DISPLAY 4:26 1 -JUN-86 alarm status = NO ALARM [ 4 CCT CO TRUNK : 2 ] OPTION NAME [SUPERVISION PARAMETER ] Far-end gives answer supervision Inhibit automatic supervision No seize alarm No release alarm Toll office Is this a CO DTMF Impedance Dictation Trunk STATUS NO NO YES YES NO YES YES COMPLEX NO Far-end gives supervision NO I-YES 2- 3- 4- 5- 6-QUIT 7- 8- 9- O-...
Page 309
Customer Data Entry (CDE) 4.56 Commands l-YES, NO, COMPLEX, 600 OHM, 60/40, IMMED This softkey toggles the status of the parameters. 2-30/20, WINK This softkey toggles the status of the parameters. 3-66/33, DELAY This softkey toggles the status of the parameters. 4-DELAY INTEG This softkey toggles the status of the parameters. B-QUIT Pressing the QUIT softkey when editing this form returns the display to the level before the field was modified. The change is not saved. The following warning...
Page 310
Customer Data Entry (CDE) Form 14 - Non-Dial-In Trunks 4.57 This form specifies the characteristics of the system’s Non- Dial-In Trunks. These trunks cannot dial any digits into the PABX and are usually a CO Trunk. The Day, Nl, N2 answer points are assigned in this form. Alternate recall points are assigned in Form 19 (refer to Table 4-29, Call Rerouting Table). Refer to Table 4-22, Non- Dial-In Trunks for the form layout. 4.58 Field Description BAY, SLT, and CCT Fields These fields list the...