Page 381
Customer Data Entry (CDE) TABLE 4-45 (CONT’D) PROGRAMMING ERROR MESSAGES Error Message Access Code XXXXX conflicts with SUPERSET line number Meaning The code entered has already been defined as a SUPERSET@ line extension number in Form 09, SUPERSET@ Set Lines. Select a new code or change the SUPERSET@ line extension number. Access Code XXXXX conflicts with the The code entered has already been defined as a Hun Access Code for HUNT GROUP NUM XX Group Access Code in Form 17, Hunt Groups. Select...
Page 382
Customer Data Entry (CDE) TABLE 4-45 (CONT’D) PROGRAMMING ERROR MESSAGES Error Message Meaning Attempting to enter invalid access code A blank access code is not allowed. Attempting update/delete of a device that The selected device is being used; modify this device is currently in use at a later time. Bay/Slot/Circuit XX/XX/XX is already The specified bay/slot/circuit is assigned elsewhere. assigned Select a new bay/slot/circuit number or change the assignment of that bay/slot/circuit number....
Page 383
Customer Data Entry (CDE) TABLE 4-45 (CONT’D) PROGRAMMING ERROR MESSAGES Error Message Iisk is write-protected - data was not Nritten to disk Meaning Remove the write-protect tag from the disk. Re-insert the disk in the disk drive and activate the write process again. Iisk is not ready - data was not written The disk was not ready. initiate the write process at :o disk a later time. Iisk I/O failure - database may be Due to the disk I/O failure, the database may be zorrupted corrupted. Exit...
Page 384
Customer Data Entry (CDE) TABLE 4-45 (CONT’D) PROGRAMMING ERROR MESSAGES Error Message Iorm number XX cannot be accessed Meaning The selected form number is reserved for future use or the selected form number has restricted user access. Refer to Form 27, Form Access Restriction for the level of access for each form. ‘arm number out of range! The selected Form number is invalid. The range is 1 to 32 with the exception of Forms 11, 12 and 28. Refer to Table 4-2, Available Forms. iigh power...
Page 385
Customer Data Entry (CDE) TABLE 4-45 (CONT’D) PROGRAMMING ERROR MESSAGES Error Message Meaning Must delete the appearances of XXXXX All appearances of the station number (or Prime Line on all sets before deleting set number) must be deleted before that set can be removed from the system. Must enter first choice for route list to be In Form 24, ARS: Route Lists, the FIRST field must be defined (leave no gaps) specified with a valid Route List number before the SECOND field is specified. Neither...
Page 386
Customer Data Entry (CDE) TABLE 4-45 (CONT’D) PROGRAMMING ERROR MESSAGES Error Message Meaning ROUTE LIST out of range. Valid range is The selected Route List number is invalid. The range (1 - 100) is 1 to 100. Refer to Form 24, ARS: Route Lists. ROUTE out of range. Valid range is (1 - The selected Route number is invalid. The range is 1 200) to 200. Refer to Form 23, ARS: Route Definition. ROUTE PLAN out of range. Valid range is The selected Route Plan number is invalid. The range (1 - 50) is 1...
Page 387
Customer Data Entry (CDE) TABLE 4-45 (CONT’D) PROGRAMMING ERROR MESSAGES Error Message Meaning The Bay/Slot/Circuit - XX/XX/XX cannot Devices are assigned to the selected bay/slot/circuit. be programmed Before a new card type can be programmed for the bay/slot/circuit, these devices must be removed frorr the system’s database. The Bay/Slot/Circuit - XX/XX/XX is not The specified circuit number is not applicable for present these bay and slot numbers. Re-enter the bay and slot numbers without...
Page 388
Customer Data Entry (CDE) TABLE 4-45 (CONT’D) PROGRAMMING ERROR MESSAGES Error Message Meaning The power rating of the UNIVERSAL CARD The power rating of the Universal Card is IO. s exceeded. Therefore, the number of modules that can be installed on the Universal Card depends on the individual power rating of the modules. The Console Module has a power rating of 5, the Receiver/Relay Module has a power rating of 2, the Music on Hold/Pager Module has a power rating of 1 and the E&M Trunk Module...
Page 389
Customer Data Entry (CDE) TABLE 4-45 (CONT’D) PROGRAMMING ERROR MESSAGES Error Message Meaning -he value X is outside valid range for The selected Hunt Group number is invalid. The iUNT GROUP (1 - 50) range is 1 to 50. -he value XX is outside valid range for In Form 29, Device Interconnection Table, there are NTERCONNECT NUMBER (1 - XX) only 25 Interconnect Numbers. -he value XX is outside valid range for The selected Pickup Group number is invalid; the ‘ICKUP GROUP (1 - 50) range is 1 to 50....
Page 390
Customer Data Entry (CDE) TABLE 4-45 (CONT’D) PROGRAMMING ERROR MESSAGES Error Message Meaning Total string is too long. Limit is 26 digits The total number of digits in the DIGITS TO BE ANALYZED field plus the digits in the LEADING DIGITS field cannot exceed 26. Refer to Form 26, Digit Strings. TRUNK GROUP must be entered for a route to be defined To complete the Route definition, the Trunk Group number must be specified. Refer to Form 23, ARS: Route Definition. TRUNK NUMBER XX does not...