Page 421

System Test Procedures 
CHART 2-16 
REMOVING EQUIPMENT FROM AND RETURNING EQUIPMENT TO SERVICE 
Step Action Verify 
1 Access MAINTENANCE System responds by displaying Maintenance menu. 
application. 
2 Press 3 (DIAGNOSTICS Softkey prompts change. Diagnostics Level is accessed. 
softkey). 
3 Press 0 (MORE-KEYS Softkey prompts change. 
softkey). 
4 Press 3 (BUSY-OUT Command line responds with: 
softkey). BUSY-OUT 
and softkey prompts change. 
5 Select qualifier, by pressing System prompts for input, and no...

Page 422

System Test Procedures 
Traffic Measurement 
2.17 
The Traffic Measurement Level (accessed from the Maintenance 
menu of the Maintenance Terminal) allows the user to SET and 
SHOW, Traffic Measurement parameters, and PRINT and READ Traffic 
Measurement reports from the Maintenance Terminal. Chart 2-17 
shows the steps for testing the Traffic Measurement Level. 
CHART 2-17 
TRAFFIC MEASUREMENT 
Step Action Verify 
1 
Access MAINTENANCE System responds by displaying Maintenance menu. 
application. 
2 Press...

Page 423

System Test Procedures 
CHART 2-17 (CONT’D) 
TRAFFIC MEASUREMENT 
Step Action Verify 
9 
Press 0 (ENTER softkey). Command line clears, and display area displays Traffic 
Measurement status, measurement units, period, duration, 
autoprint status, and condensed report status. Softkey 
prompts return to Traffic Measurement Level format. 
10 Press 3 (PRINT softkey). Command line responds with: 
PRINT TRAFFRPT ALL 
and softkey prompts change. 
11 Press 0 (ENTER softkey). Command line clears, softkey prompts...

Page 424

System Test Procedures 
CHART 2-17 (CONT’D) 
TRAFFIC MEASUREMENT 
Step Action Verify 
15 Press 1 (TRAFFRPT softkey). Command line responds with: 
STOP TRAFFRPT 
and softkey prompts change. 
16 Press 0 (ENTER softkey). Command line clears, STOP TRAFFRPT message appears in 
display area, traffic reports are halted, and softkey 
prompts return to Traffic Measurement Level ‘format. 
17 Repeat Step 14. 
18 Press 3 (PRINT softkey). Command line responds with: 
STOP PRINT TM 
and softkey prompts change. 
19...

Page 425

System Test Procedures 
Logs 
2.18 
The Logs Level (accessed from the Maintenance menu of the 
Maintenance Terminal) allows the user to read, print, and delete 
maintenance log entries made by the system. Log entries consist of 
anything which affects the functioning of the system, such as failed 
circuits, removed or installed cards, and Bay resets. Chart 2-18 shows 
the steps for testing the Logs Level. 
CHART 2-18 
LOGS LEVEL 
Step Action Verify 
1 Access MAINTENANCE System responds by displaying...

Page 426

Step Action Verify 
10 Repeat Steps 6 and 7. As in Step 7. 
Go to Step 11. 
11 Press 2 (OFF softkey). Command line responds with: 
SET AUTOPRINT LOGS OFF 
and sof-tkey prompts change. 
12 Press 0 (ENTER softkey). Command line clears, SET AUTOPRINT LOGS OFF message 
appears in display area, and softkey prompts return to 
Logs Level format. Autoprint is disabled. 
13 Press 2 (READ softkey). Command line responds with: 
READ LOGS 
and softkey prompts change. 
14 Select READ LOGS qualifier If NEWEST or...

Page 427

System Test Procedures 
CHART 2-18 (CONT’D) 
LOGS LEVEL 
Step 1 Action Verify 
18 
19 
20 
21 Generate a log entry by 
extracting then re-installin: 
a voice card. DO NOT 
extract any of the 
following: 
l fvlain Control Card 
l Digital Interface Cards 
l Peripheral Control Cards 
l Scanner Cards 
Repeat Steps 13-l 5, 
selecting NEWEST as the 
READ LOGS qualifier, and 
when instructed enter 002 
to read the two newest lo{ 
entries. 
Press 0 (ENTER softkey). 
Press 3 (PRINT softkey). 
Select a PRINT LOGS...

Page 428

System Test Procedures 
CHART 2-18 (CONT’D) 
LOGS LEVEL 
Step Action Verify 
22 Press 0 (ENTER softkey). 
Selected logs are printed on printer. Softkey prompts 
return to Logs Level format. 
NOTE: Printing of logs can 
be halted at any time by 
pressing 9 (STOP softkey) 
and 0 (ENTER softkey). 
23 Press 4 (DELETE softkey). Command line responds with: 
DELETE LOGS 
and softkey prompts change. 
24 Select DELETE LOGS 
Command line responds with: 
qualifier by pressing either 
1 (NEWEST softkey) 
DELETE LOGS...

Page 429

System Test Procedures 
Reports 
2.19 
The Reports Level (accessed from the Maintenance Menu of the 
Maintenance Terminal) allows the user to have various main- 
tenance reports displayed. The types of reports available are: System 
Configuration, Alarm Status, Circuit Status, and SUPERSET qTM Set 
Errors. For further information regarding these, refer to Section 
MITL9108-093-351-NA, RS-232 Maintenance Terminal. Chart 2-19 
shows the steps for testing the Reports Level commands. 
CHART 2-19 
REPORTS...

Page 430

System Test Procedures 
CHART 2-19 (CONT’B) 
REPORTS 
Step Action Verify 
8 Repeat Steps 5 through 7 Go to Step 9. 
for remaining SHOW 
CONFIG qualifiers. 
9 Press 2 (SHOW softkey). As in Step 3. 
10 Press 2 (ALARMS softkey). Command line responds with: 
SHOW ALARMS 
and softkey prompts change. 
11 Select an ALARMS qualifier Command line responds with: 
by pressing either 2 SHOW ALARMS 
(DEVICE TYPE softkey) or 4 
(ALL softkey). or: 
SHOW ALARMS ALL 
and softkey prompts change. 
12 If 2 was pressed in...