System Test Procedures 
CHART 5-13 (CONT’D) 
ATTENDANT CALL FORWARDING 
Step Action Verify 
12 Press CANCEL softkey. LCD display returns to idle condition. (Call Forwarding is 
canceled at station “A”.) 
13 Repeat Step 9. Station “A” rings. Attendant Console receives Ringback 
Tone. Station “A” appears as DST. 
14 Press RELEASE. Station “A” stops ringing. Ringback Tone removed from 
Attendant Console. Attendant Console display returns to 
idle condition. 
15 Repeat Steps 1 through 5. Call Forwarding is...

Page 472

System Test Procedures 
CHART 5-14 
ATTENDANT STATION BUSY-OUT 
3 Press STATIONS softkey. 
4 
8 
9 
10 
11 
12 
13 
14 
15 Press the FUNCTION key. Function softkeys are displayed. 
Press ATT FUNCTION 
softkey. 
Enter station “A” directory Digits are displayed on LCD display as they are entered 
number. from telephony keypad. BUSY OUT softkey is displayed. 
Press BUSY OUT softkey. 
Press SET softkey. 
Station “B” lifts handset 
and dials station “A” 
directory number. 
Station “B” sets handset 
on-hook....

Page 473

System Test Procedures 
CHART 5-15 
ATTENDANT DIRECT TRUNK SELECT 
Step Action Verify 
1 Press the FUNCTION key. Function softkeys are displayed. 
2 Press ATT FUNCTION Softkey prompts change. 
softkey. 
3 Press TRUNKS softkey. Attendant Console LCD display responds 
by displaying the message: 
Enter Trunk Number:- 
4 Enter trunk number. Digits are displayed on LCD as they are entered from the 
telephony keypad. ATT ACCESS softkey is displayed. 
5 Press ATT ACCESS softkey. DST display shows selected...

Page 474

System Test Procedures 
CHART 5-17 
ATTENDANT DISPLAY OF SUPERSET qTM SET MESSAGES 
Step Action Verify 
1 At a SUPERSET qTM set, SUPERSET qTM LCD displays the message enabled. 
enable a message. 
2 Attendant dials the Attendant Console DST display shows the SUPERSET qTM 
SUPERSET qTM set directory set data. The message enabled at the SUPERSET qTM set is 
number. displayed. The SUPERSET qTM set rings. The Attendant 
Console receives Ringback Tone. 
3 Press the RELEASE key. Attendant Console returns to...

Page 475

System Test Procedures 
CHART 5-19 
ATTENDANT NIGHT SWITCHING 
Step Action Verify 
1 Press the FUNCTION key. Function softkey prompts are displayed. 
2 Press the NIGHT 1 softkey. Attendant Console returns to idle condition. System enters 
Night Service 1. NIGHT 1 status flag is displayed on 
Attendant Console LCD. 
3 Station “A“ lifts handset, Night Service 1 night bells are rung. Station “A“ receives 
accesses an outgoing Ringback Tone. Call does not appear at Attendant Console. 
trunk, then accesses an...

Page 476

System Test Procedures 
CHART 5-20 
SYSTEM IDENTIFIER 
Step Action Verify 
1 Press the FUNCTION key. Function softkey prompts are displayed. 
2 Press the IDENTITY System identity (including software release) and Attendant 
SOFTKEY. Console LDN are displayed on Attendant Console LCD. 
3 Press the EXIT softkey. Attendant Console returns to idle condition. Test 
completed. 
Page 5-19  

Page 477

System Test Procedures 
Maintenance and Customer Data Entry Applications 
5.04 For this test, ensure that Maintenance and Customer Data Entry 
Applications are not accessed by any Maintenance Terminal or 
Attendant Console. 
CHART 5-21 
MAINTENANCE AND CUSTOMER DATA ENTRY APPLICATIONS 
Step Action Verify 
1 Press the FUNCTION key. Function softkey prompts are displayed. 
2 Press the APPLICATION Attendant Console LCD responds by displaying the 
SOFTKEY. message: 
Choose An Application OR Depress Any Hard...

Page 478

System Test Procedurd 
CHART 5-21 (CONT’D) 
MAINTENANCE AND CUSTOMER DATA ENTRY APPLICATIONS 
Step Action Verify 
11 
Press the RELEASE key. 
12 
13 
14 
15 Press the CDE softkey. Attendant Console LCD display responds as in Step 3. 
Repeat Steps 4 through 6. 
16 Repeat Steps 7 through 10 
17 Repeat Step 11. 
18 Press the QUIT softkey. 
19 Press any fixed key.  Press ANSWER or Station “A” and Attendant Console are connected. 
INTERNAL softkey. ANSWER LED is on. SRC display shows station “A” data. 
Press...

Page 479

System Test Procedures 
6. CUSTOMER FEATURE TESTS 
Class-of-Service Tests 
6.01 The system has up to 50 Classes of Service. One station for 
each Class of Service is selected. Each option for that station is 
then tested. 
1. 
2. 
3. Refer to the Class-of-Service Option forms. Make a note of 
each of the COS Numbers. 
Refer to the Station Assignment forms. Each station is assigned 
a COS Number. For each COS Number, select a station number. 
Again refer to the Class-of-Service Option forms. For each...