GuestWorks Issue 6 Technician Handbook  555-231-109  Issue 1
April 2000
Installing the System 
61 Connecting the Hospitality Adjuncts 
7400A Options
The options for the 7400A used for the switch-to-PMS connection are given in 
Ta b l e 5
. These options must match the PMS communication parameters, which 
are usually 9600 bps, 8 data bits, 1 stop bit, and no parity.
The data module interface board must be positioned at the DCE location, and the 
interface option must be set for Answer-Only mode.
Table 5....

Page 72

GuestWorks Issue 6 Technician Handbook  555-231-109  Issue 1
April 2000
Installing the System 
62 Connecting the Hospitality Adjuncts 
7400B Options
The options on the 7400B must be set using an ASCII data terminal or a PC using 
a terminal emulation package. You must connect the data terminal or PC to the 
EIA interface connector on the back of the 7400B. For the switch-to-PMS link, only 
a subset of options must be changed. These options are changed using the AT 
command set. Use the following steps to...

Page 73

GuestWorks Issue 6 Technician Handbook  555-231-109  Issue 1
April 2000
Installing the System 
63 Connecting the Hospitality Adjuncts 
With the mini-tester connected to only the data module, the mini-tester should 
show the following:
NOTE:
The CTS lead shows green when used with an 8400B. RTS will be lit on the 
front panel of the 7400A or 7400B. 
With the mini-tester connected to only the PMS, the mini-tester should show the 
following:
With the mini-tester connected to the data module and the PMS, the...

Page 74

GuestWorks Issue 6 Technician Handbook  555-231-109  Issue 1
April 2000
Installing the System 
64 Connecting the Hospitality Adjuncts 
Journal/PMS Log or System Printer Connections
on the Switch
These printers are used to run hospitality service reports, to report failed Auto-
matic Wakeup calls and Do Not Disturb requests, or to run Basic Call Manage-
ment System (BCMS) reports.
NOTE:
In most cases, only one printer is provided to perform both the journal/
schedule and PMS log printer functions. The...

Page 75

GuestWorks Issue 6 Technician Handbook  555-231-109  Issue 1
April 2000
Installing the System 
65 Connecting the Hospitality Adjuncts 
Cabling Diagram
Figure 18 shows how to connect a journal/schedule printer, a PMS log printer, or a 
system printer to the switch.
Figure 18. Printer Connections on the Switch 

Page 76

GuestWorks Issue 6 Technician Handbook  555-231-109  Issue 1
April 2000
Installing the System 
66 Connecting the Hospitality Adjuncts 
8400B Options
The options on the 8400B must be set using an ASCII data terminal or a PC using 
a terminal emulation package. You must connect the data terminal or PC to the 
EIA interface connector on the back of the 8400B. For the journal/log printers, a 
subset of options must be changed. These options are changed using the AT 
command set. Use the following steps to...

Page 77

GuestWorks Issue 6 Technician Handbook  555-231-109  Issue 1
April 2000
Installing the System 
67 Connecting the Hospitality Adjuncts 
7400A Options
The options for the 7400A used for printers are given in Ta b l e 6. These options 
must match the printer communication parameters, which are usually 9600 bps, 8 
data bits, 1 stop bit, and no parity.
The data module interface board must be positioned at the DCE location, and the 
interface option must be set for Answer-Only mode.
Table 6. 7400A Options for...

Page 78

GuestWorks Issue 6 Technician Handbook  555-231-109  Issue 1
April 2000
Installing the System 
68 Connecting the Hospitality Adjuncts 
7400B Options
The options on the 7400B must be set using an ASCII data terminal or a PC using 
a terminal emulation package. You must connect the data terminal or PC to the 
EIA interface connector on the back of the 7400B. For the journal/log printers, only 
a subset of options must be changed. These options are changed using the AT 
command set. Use the following steps...

Page 79

GuestWorks Issue 6 Technician Handbook  555-231-109  Issue 1
April 2000
Installing the System 
69 Connecting the Hospitality Adjuncts 
Okidata Model ML321T Journal/PMS Log
Printer Options
Using the serial interface card (comcode 406940577), option the printer as follows 
for a journal or PMS log printer:
1. Press SHIFT + SEL to enter the Menu Mode.
2. Press Print (Park) to print out the Groups and Items. The first Group/Item to 
come up will be Printer Control/Emulation Control.
3. Press SET to option...

Page 80

GuestWorks Issue 6 Technician Handbook  555-231-109  Issue 1
April 2000
Installing the System 
70 Connecting the Hospitality Adjuncts 
Okidata Model ML321T System Printer Options
Using the serial interface card (comcode 406940577), option the printer as follows 
for a system printer:
1. Press SHIFT + SEL to enter the Menu Mode.
2. Use the GROUP, ITEM, and SET keys to make changes:
nPress GROUP until the group you wish to change appears in the 
first column.
nPress ITEM until the item you wish to change...