Page 51

GuestWorks Issue 6 Technician Handbook  555-231-109  Issue 1
April 2000
Installing the System 
41 Connecting the Hospitality Adjuncts 
Switch-to-Call Accounting Link (with
Co-Resident INTUITY Lodging Call Accounting)
This connection is used to transfer Call Detail Recording (CDR) information to the 
co-resident INTUITY Lodging Call Accounting software (Homisco). This connec-
tion is valid for a 
csi or si system.
Parts List
nThe DCE port on the switch (this port is found on the Processor Interface 
Cable...

Page 52

GuestWorks Issue 6 Technician Handbook  555-231-109  Issue 1
April 2000
Installing the System 
42 Connecting the Hospitality Adjuncts 
Cabling Diagram
Figure 11 shows the connection used to transfer CDR information between the 
DCE port on a 
csi or si system and the MAP.
Figure 11. Switch-to-Call Accounting Link (with Co-Resident INTUITY 
Lodging Call Accounting)
Test Procedure 
Using the RS232 Mini-Tester (see the Note on Pa ge 1 1), check the status of the 
link where the Equinox adapter connects to...

Page 53

GuestWorks Issue 6 Technician Handbook  555-231-109  Issue 1
April 2000
Installing the System 
43 Connecting the Hospitality Adjuncts 
With the mini-tester connected to only the M25A cable, the mini-tester should 
show the following:
With the mini-tester connected to only the Equinox adapter, the mini-tester should 
show the following:
With the mini-tester connected to the M25A cable and the Equinox adapter, the 
mini-tester should show the following (if any of the switch leads are dark on an 
end-to-end...

Page 54

GuestWorks Issue 6 Technician Handbook  555-231-109  Issue 1
April 2000
Installing the System 
44 Connecting the Hospitality Adjuncts 
Switch-to-Call Accounting Link (Xiox Call
Accounting System)
This connection is used to transfer CDR information to the Xiox call accounting 
system. This connection is valid for a 
csi or si system.
Parts List
nThe DCE port on the switch (this port is found on the Processor Interface 
Cable of a 
csi system labeled as J2)
nOne M25A or M25B cable plus gender changers as...

Page 55

GuestWorks Issue 6 Technician Handbook  555-231-109  Issue 1
April 2000
Installing the System 
45 Connecting the Hospitality Adjuncts 
Cabling Diagram
Figure 12 shows the connection between the DCE port on a csi or si system and a 
Xiox call accounting system.
Figure 12.Switch-to-Call Accounting Link (Xiox Call Accounting 
System)
Test Procedure 
Using the RS232 Mini-Tester (see the Note on Pa ge 1 1), check the status of the 
link at the point where the M25 cable connects to the Xiox Intelligent Buffer...

Page 56

GuestWorks Issue 6 Technician Handbook  555-231-109  Issue 1
April 2000
Installing the System 
46 Connecting the Hospitality Adjuncts 
With the mini-tester connected to only the M25 cable from the switch, the mini-
tester should show the following:
With the mini-tester connected to only the PBX port on the Xiox Intelligent Buffer, 
the mini-tester should show the following:
With the mini-tester connected to the switch and the PBX port on the Xiox 
Intelligent Buffer, the mini-tester should show the...

Page 57

GuestWorks Issue 6 Technician Handbook  555-231-109  Issue 1
April 2000
Installing the System 
47 Connecting the Hospitality Adjuncts 
Switch-to-Call Accounting Link (Stand-alone Call
Accounting Systems)
This connection is used to transfer CDR information to a stand-alone call account-
ing system. This connection is valid for a 
csi or si system.
Parts List
nThe DCE port on the switch (this port is found on the Processor Interface 
Cable of a 
csi system labeled as J2)
nOne M25A or M25B cable plus gender...

Page 58

GuestWorks Issue 6 Technician Handbook  555-231-109  Issue 1
April 2000
Installing the System 
48 Connecting the Hospitality Adjuncts 
Test Procedure 
Using the RS232 Mini-Tester (see the Note on Pa ge 1 1), check the status of the 
link at the demarcation point as shown in Figure 13
. The leads marked with an 
asterisk are controlled by the switch, and the call accounting system controls the 
other leads. Translations for this connection begin on Page 200
.
!CAUTION:
After using a mini-tester to check...

Page 59

GuestWorks Issue 6 Technician Handbook  555-231-109  Issue 1
April 2000
Installing the System 
49 Connecting the Hospitality Adjuncts 
With the mini-tester connected to the switch and the stand-alone call accounting 
system, the mini-tester should show the following (if any of the switch leads are 
dark in an end-to-end connection, the processor circuit pack should be replaced):
Another way to test this connection is to connect a dumb terminal to the DCE port 
on the switch, make some test calls, and...

Page 60

GuestWorks Issue 6 Technician Handbook  555-231-109  Issue 1
April 2000
Installing the System 
50 Connecting the Hospitality Adjuncts 
Switch-to-Call Accounting Link using DCP
Data Modules
This connection is used when the distance between the switch and the call 
accounting system is greater than 50 feet (15.2 meters), or when using an 
r sys-
tem.
Parts List
Co-Resident INTUITY Lodging Call Accounting (Homisco)
nOne digital communications protocol (DCP) port on the switch; the 8400B 
data module uses a...