Page 51
GuestWorks Issue 6 Technician Handbook 555-231-109 Issue 1 April 2000 Installing the System 41 Connecting the Hospitality Adjuncts Switch-to-Call Accounting Link (with Co-Resident INTUITY Lodging Call Accounting) This connection is used to transfer Call Detail Recording (CDR) information to the co-resident INTUITY Lodging Call Accounting software (Homisco). This connec- tion is valid for a csi or si system. Parts List nThe DCE port on the switch (this port is found on the Processor Interface Cable...
Page 52
GuestWorks Issue 6 Technician Handbook 555-231-109 Issue 1 April 2000 Installing the System 42 Connecting the Hospitality Adjuncts Cabling Diagram Figure 11 shows the connection used to transfer CDR information between the DCE port on a csi or si system and the MAP. Figure 11. Switch-to-Call Accounting Link (with Co-Resident INTUITY Lodging Call Accounting) Test Procedure Using the RS232 Mini-Tester (see the Note on Pa ge 1 1), check the status of the link where the Equinox adapter connects to...
Page 53
GuestWorks Issue 6 Technician Handbook 555-231-109 Issue 1 April 2000 Installing the System 43 Connecting the Hospitality Adjuncts With the mini-tester connected to only the M25A cable, the mini-tester should show the following: With the mini-tester connected to only the Equinox adapter, the mini-tester should show the following: With the mini-tester connected to the M25A cable and the Equinox adapter, the mini-tester should show the following (if any of the switch leads are dark on an end-to-end...
Page 54
GuestWorks Issue 6 Technician Handbook 555-231-109 Issue 1 April 2000 Installing the System 44 Connecting the Hospitality Adjuncts Switch-to-Call Accounting Link (Xiox Call Accounting System) This connection is used to transfer CDR information to the Xiox call accounting system. This connection is valid for a csi or si system. Parts List nThe DCE port on the switch (this port is found on the Processor Interface Cable of a csi system labeled as J2) nOne M25A or M25B cable plus gender changers as...
Page 55
GuestWorks Issue 6 Technician Handbook 555-231-109 Issue 1 April 2000 Installing the System 45 Connecting the Hospitality Adjuncts Cabling Diagram Figure 12 shows the connection between the DCE port on a csi or si system and a Xiox call accounting system. Figure 12.Switch-to-Call Accounting Link (Xiox Call Accounting System) Test Procedure Using the RS232 Mini-Tester (see the Note on Pa ge 1 1), check the status of the link at the point where the M25 cable connects to the Xiox Intelligent Buffer...
Page 56
GuestWorks Issue 6 Technician Handbook 555-231-109 Issue 1 April 2000 Installing the System 46 Connecting the Hospitality Adjuncts With the mini-tester connected to only the M25 cable from the switch, the mini- tester should show the following: With the mini-tester connected to only the PBX port on the Xiox Intelligent Buffer, the mini-tester should show the following: With the mini-tester connected to the switch and the PBX port on the Xiox Intelligent Buffer, the mini-tester should show the...
Page 57
GuestWorks Issue 6 Technician Handbook 555-231-109 Issue 1 April 2000 Installing the System 47 Connecting the Hospitality Adjuncts Switch-to-Call Accounting Link (Stand-alone Call Accounting Systems) This connection is used to transfer CDR information to a stand-alone call account- ing system. This connection is valid for a csi or si system. Parts List nThe DCE port on the switch (this port is found on the Processor Interface Cable of a csi system labeled as J2) nOne M25A or M25B cable plus gender...
Page 58
GuestWorks Issue 6 Technician Handbook 555-231-109 Issue 1 April 2000 Installing the System 48 Connecting the Hospitality Adjuncts Test Procedure Using the RS232 Mini-Tester (see the Note on Pa ge 1 1), check the status of the link at the demarcation point as shown in Figure 13 . The leads marked with an asterisk are controlled by the switch, and the call accounting system controls the other leads. Translations for this connection begin on Page 200 . !CAUTION: After using a mini-tester to check...
Page 59
GuestWorks Issue 6 Technician Handbook 555-231-109 Issue 1 April 2000 Installing the System 49 Connecting the Hospitality Adjuncts With the mini-tester connected to the switch and the stand-alone call accounting system, the mini-tester should show the following (if any of the switch leads are dark in an end-to-end connection, the processor circuit pack should be replaced): Another way to test this connection is to connect a dumb terminal to the DCE port on the switch, make some test calls, and...
Page 60
GuestWorks Issue 6 Technician Handbook 555-231-109 Issue 1 April 2000 Installing the System 50 Connecting the Hospitality Adjuncts Switch-to-Call Accounting Link using DCP Data Modules This connection is used when the distance between the switch and the call accounting system is greater than 50 feet (15.2 meters), or when using an r sys- tem. Parts List Co-Resident INTUITY Lodging Call Accounting (Homisco) nOne digital communications protocol (DCP) port on the switch; the 8400B data module uses a...