GuestWorks Issue 6 Technician Handbook  555-231-109  Issue 1
April 2000
Installing the System 
51 Connecting the Hospitality Adjuncts 
Distance Limits
The distance limit when connecting a data module to a TN2214 or TN2224 with 24 
AWG wire is 3500 feet (1067 meters). The distance limit when connecting a data 
module to a TN754C is 5000 feet (1524 meters) with 24 AWG wire, and 4000 feet 
(1219 meters) with 26 AWG wire.
Cabling Diagram
Figure 14 shows the connection between the switch and the call...

Page 62

GuestWorks Issue 6 Technician Handbook  555-231-109  Issue 1
April 2000
Installing the System 
52 Connecting the Hospitality Adjuncts 
8400B Options
The options on the 8400B must be set using an ASCII data terminal or a PC using 
a terminal emulation package. You must connect the data terminal or PC to the 
EIA interface connector on the back of the 8400B. For the switch-to-call account-
ing link, a subset of options must be changed. These options are changed using 
the AT command set. Use the following...

Page 63

GuestWorks Issue 6 Technician Handbook  555-231-109  Issue 1
April 2000
Installing the System 
53 Connecting the Hospitality Adjuncts 
7400A Options
The options for the 7400A used for the switch-to-call accounting connection are 
given in Ta b l e 4
. These options must match the call accounting system communi-
cation parameters, which are usually 9600 bps, 8 data bits, 1 stop bit, and no par-
ity.
The data module interface board must be positioned at the DCE location, and the 
interface option must be...

Page 64

GuestWorks Issue 6 Technician Handbook  555-231-109  Issue 1
April 2000
Installing the System 
54 Connecting the Hospitality Adjuncts 
7400B Options
The options on the 7400B must be set using an ASCII data terminal or a PC using 
a terminal emulation package. You must connect the data terminal or PC to the 
EIA interface connector on the back of the 7400B. For the switch-to-call account-
ing link, only a subset of options must be changed. These options are changed 
using the AT command set. Use the...

Page 65

GuestWorks Issue 6 Technician Handbook  555-231-109  Issue 1
April 2000
Installing the System 
55 Connecting the Hospitality Adjuncts 
INTUITY Lodging Call Accounting-to-PMS Link
This connection is used to transmit the call accounting information from the MAP 
to the PMS. This call detail information has been reformatted from its format on 
the switch for use by the PMS.
NOTE:
This link between the co-resident INTUITY Lodging Call Accounting pack-
age and the PMS is required to transmit call detail...

Page 66

GuestWorks Issue 6 Technician Handbook  555-231-109  Issue 1
April 2000
Installing the System 
56 Connecting the Hospitality Adjuncts 
Cabling Diagram
Figure 15 shows the INTUITY Lodging Call Accounting connection between the 
MAP and a PMS.
Figure 15. INTUITY Lodging Call Accounting-to-PMS Link 

Page 67

GuestWorks Issue 6 Technician Handbook  555-231-109  Issue 1
April 2000
Installing the System 
57 Connecting the Hospitality Adjuncts 
Xiox Call Accounting-to-PMS Link
This connection is used to transmit the call accounting information from the Xiox 
call accounting system to the PMS. This call detail information has been reformat-
ted from its format on the switch for use by the PMS.
Parts List
nOne standard null modem serial cable to connect from COM2 on the Xiox 
call accounting PC to the call...

Page 68

GuestWorks Issue 6 Technician Handbook  555-231-109  Issue 1
April 2000
Installing the System 
58 Connecting the Hospitality Adjuncts 
Switch-to-PMS Link
This connection is used to transfer the normal hospitality information between the 
switch and the PMS, such as names registration, check-in, check-out, and so on.
Parts List
nOne digital communications protocol (DCP) port on the switch; the 8400B 
data module uses a TN2214 or TN2224 2-wire digital port, and the 7400A 
and 7400B data modules use a...

Page 69

GuestWorks Issue 6 Technician Handbook  555-231-109  Issue 1
April 2000
Installing the System 
59 Connecting the Hospitality Adjuncts 
Cabling Diagram
Figure 17 shows the connection between the switch and the PMS.
Figure 17. Switch-to-PMS Link 

Page 70

GuestWorks Issue 6 Technician Handbook  555-231-109  Issue 1
April 2000
Installing the System 
60 Connecting the Hospitality Adjuncts 
8400B Options
The options on the 8400B must be set using an ASCII data terminal or a PC using 
a terminal emulation package. You must connect the data terminal or PC to the 
EIA interface connector on the back of the 8400B. For the switch-to-PMS link, a 
subset of options must be changed. These options are changed using the AT 
command set. Use the following steps to set...